Feasibility of optimal vertex size and spacing for lattice radiotherapy implementation using helical tomotherapy

被引:0
|
作者
Seol, Yunji [1 ]
Lee, Young Kyu [1 ]
Kim, Byeong Jin [1 ]
Choi, Kyu Hye [1 ]
Hong, Ji Hyun [1 ]
Park, Chan-beom [2 ]
Kim, Sun Hwa [2 ]
Park, Hyeong Wook [3 ]
Kim, Jung-Il [4 ]
Cheon, Wonjoong [1 ]
Kang, Young-nam [1 ]
Choi, Byung Ock [1 ]
机构
[1] Catholic Univ, Seoul St Marys Hosp, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[2] Catholic Univ Korea, Dept Biomed & Hlth Sci, Seoul, South Korea
[3] Kyonggi Univ, Dept Med Phys, Suwon, South Korea
[4] Korea Electrotechnol Res Inst, Electromed Device Res Ctr, Ansan, South Korea
来源
FRONTIERS IN ONCOLOGY | 2025年 / 15卷
关键词
lattice radiotherapy; spatially fractionated radiotherapy; helical tomotherapy; vertex; valley-to-peak dose ratio; FRACTIONATED RADIATION-THERAPY; LUNG-CANCER;
D O I
10.3389/fonc.2025.1512064
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose Lattice radiotherapy (LRT), a type of spatially fractionated radiotherapy (SFRT), delivers high dose at specific volumes of lattice structure within the tumor to create a low valley-to-peak dose ratio (VPDR). This study aims to evaluate the feasibility of implementing SFRT using helical tomotherapy and to investigate the effects of vertex size and spacing for attaining the VPDR.Methods A three-dimensional lattice structure with 3x3x3 vertices was designed in a cheese phantom. Vertex sizes of 0.5 cm, 1.0 cm, and 2.0 cm were assessed, with spacing from 1.0 cm to 5.0 cm. The prescribed dose was set to 20 Gy to the vertices in a single fraction. VPDR was calculated from dose profiles along lines connecting three vertices in the anterior-posterior (AP), lateral (LAT), and superior-inferior (SI) directions. The minimum, maximum, and mean dose for each vertex, as well as conformity, homogeneity and monitor unit (MU) analysis were also performed.Results VPDR decreased significantly with increasing vertex size and spacing. While the AP and LAT directions showed similar VPDR values, the SI direction consistently exhibited lower VPDR values across all configurations. Vertex sizes of 0.5 cm, 1.0 cm, and 2.0 cm required spacing of at least 3.0 cm, 2.0 cm, and 1.0 cm, respectively, to achieve VPDR values below 0.4. The conformity indices ranged from 1.0 to 4.02, and the homogeneity indices ranged from 1.20 to 1.57 across all configurations. Additionally, the MUs increased with both vertex size and spacing.Conclusions This study quantitatively analyzed the impact of various vertex sizes and spacings on VPDR in lattice radiotherapy using helical tomotherapy. VPDR decreased with increasing vertex size and spacing, with consistently lower values in the SI direction. These findings provide crucial insights for optimizing LRT plans. The identified relationships between the parameters and VPDR offer a foundation for developing more effective LRT protocols in helical tomotherapy, potentially improving therapeutic outcomes
引用
收藏
页数:10
相关论文
共 36 条
  • [1] Helical tomotherapy in the radiotherapy treatment of Hodgkin's disease - a feasibility study
    Vlachaki, Maria T.
    Kumar, Sanath
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 77 - 87
  • [2] Spatially fractionated radiotherapy (GRID) using helical tomotherapy
    Zhang, Xin
    Penagaricano, Jose
    Yan, Yulong
    Liang, Xiaoying
    Morrill, Steven
    Griffin, Robert J.
    Corry, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (01): : 396 - 407
  • [3] STANDARD AND NONSTANDARD CRANIOSPINAL RADIOTHERAPY USING HELICAL TOMOTHERAPY
    Parker, William
    Brodeur, Marylene
    Roberge, David
    Freeman, Carolyn
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03): : 926 - 931
  • [4] STEREOTACTIC BODY RADIOTHERAPY WITH HELICAL TOMOTHERAPY FOR LUNG TUMOR: TREATMENT OUTCOME AND FEASIBILITY
    Kim, Sung Hwan
    Lee, Yun Hee
    Kang, Dae Gyu
    Cho, Deog Gon
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S840 - S840
  • [5] Clinical implementation of radiosurgery using the Helical TomoTherapy unit
    Saw, Cheng B.
    Gillette, Carol
    Peters, Christopher A.
    Koutcher, Lawrence
    MEDICAL DOSIMETRY, 2018, 43 (03) : 284 - 290
  • [6] Postmastectomy radiotherapy with integrated scar boost using helical tomotherapy
    Rong, Yi
    Yadav, Poonam
    Welsh, James S.
    Fahner, Tasha
    Paliwal, Bhudatt
    MEDICAL DOSIMETRY, 2012, 37 (03) : 233 - 239
  • [7] Repetitive Painting (REPEAT) Irradiation in Stereotactic Radiotherapy Using Helical Tomotherapy
    Ohkubo, Y. U.
    Kumazawa, Takuya
    Hirai, Ryuta
    Noda, Shin-Ei
    IN VIVO, 2022, 36 (01): : 330 - 335
  • [8] A Feasibility Study of a Tilted Head Position in Helical Tomotherapy for Fractionated Stereotactic Radiotherapy of Intracranial Malignancies
    Chung, Yoonsun
    Yoon, Hong In
    Ha, Jin Sook
    Kim, Seijoon
    Lee, Ik Jae
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2015, 14 (04) : 475 - 482
  • [9] Practical Aspects of Implementation of Helical Tomotherapy for Intensity-modulated and Image-guided Radiotherapy
    Burnet, N. G.
    Adams, E. J.
    Fairfoul, J.
    Tudor, G. S. J.
    Hoole, A. C. F.
    Routsis, D. S.
    Dean, J. C.
    Kirby, R. D.
    Cowen, M.
    Russell, S. G.
    Rimmer, Y. L.
    Thomas, S. J.
    CLINICAL ONCOLOGY, 2010, 22 (04) : 294 - 312
  • [10] Palliative Irradiation Using Helical Tomotherapy in Recurrent Pelvic Tumors with Prior Radiotherapy
    Kay, Chul Seung
    Yoo, Eun Jung
    Kim, Ji Hoon
    Ro, Duck Young
    Kim, Ki Jun
    RADIATION ONCOLOGY JOURNAL, 2010, 28 (03): : 133 - 140