Direct Load Current Control in Power Supply Based on DC-DC Converter and AC Current-Controlled Converter in Parallel for Electrolytic Hydrogen Production Test

被引:0
作者
Zhao, Guopeng [1 ]
Lu, Keqi [1 ]
机构
[1] North China Elect Power Univ, Beijing 102206, Peoples R China
基金
国家重点研发计划;
关键词
Voltage control; Current control; Impedance; Hydrogen; Production; Transfer functions; Capacitors; Cutoff frequency; Testing; Resistors; Converter; direct load current control; electrolytic hydrogen production; injected current; power supply; TOPOLOGY; SYSTEM;
D O I
10.1109/TIE.2024.3476935
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The topology in which a dc-dc converter and an ac current-controlled converter are connected in parallel to output dc current and ac current, respectively, is usually used in the power supply for electrolytic hydrogen production test. The ac current of the current-controlled converter is distributed by the dc-dc converter, which will affect the precision of load current control. This article proposed a novel direct load current control strategy in the ac current-controlled converter, which can provide a high-precision ac current to the load. The added inductor in the output side of the dc-dc converter can effectively reduce the distribution of the ac current. The influence and the design consideration of the added inductor on the output impedance of the dc-dc converter and the current control loop of the ac current-controlled converter are analyzed. Based on the model of the proposed control method, the comparison is made between the proposed control method and the traditional control method, and the proposed control method has higher control precision. The proposed control strategy is more suitable for situations of parallel connection between a voltage-controlled converter and a current-controlled converter.
引用
收藏
页码:5387 / 5396
页数:10
相关论文
共 28 条
[1]   Electrolyzer Durability at Low Catalyst Loading and with Dynamic Operation [J].
Alia, Shaun M. ;
Stariha, Sarah ;
Borup, Rod L. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (15) :F1164-F1172
[2]   Equivalent electrical model for a proton exchange membrane (PEM) electrolyser [J].
Atlam, Ozcan ;
Kolhe, Mohan .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (8-9) :2952-2957
[3]   Passivity-Based Design of a Fractional-Order Virtual Capacitor for Active Damping of Multiparalleled Grid-Connected Current-Source Inverters [J].
Azghandi, M. Ali ;
Barakati, S. Masoud ;
Yazdani, Amirnaser .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (07) :7809-7818
[4]  
Bintz S., 2019, P C SUST EN SUPPL EN, P50
[5]   Effect of a ripple current on the efficiency of a PEM electrolyser [J].
Buitendach, Henning P. C. ;
Gouws, Rupert ;
Martinson, Christiaan A. ;
Minnaar, Carel ;
Bessarabov, Dmitri .
RESULTS IN ENGINEERING, 2021, 10
[6]   Transient behaviors and mathematical model of proton exchange membrane electrolyzer [J].
Dang, Jian ;
Yang, Fuyuan ;
Li, Yangyang ;
Deng, Xintao ;
Ouyang, Minggao .
JOURNAL OF POWER SOURCES, 2022, 542
[7]   Overview of alkaline water electrolysis modeling [J].
Daoudi, Camilia ;
Bounahmidi, Tijani .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 49 :646-667
[8]   Single-Phase Inverter Control Techniques for Interfacing Renewable Energy Sources With Microgrid-Part I: Parallel-Connected Inverter Topology With Active and Reactive Power Flow Control Along With Grid Current Shaping [J].
Dasgupta, Souvik ;
Sahoo, Sanjib Kumar ;
Panda, Sanjib Kumar .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (03) :717-731
[9]   Stress-strain dependent rutting prediction models for multi-layer structures of asphalt mixtures [J].
Deng, Yong ;
Zhang, Yao ;
Shi, Xijun ;
Hou, Shuguang ;
Lytton, Robert L. .
INTERNATIONAL JOURNAL OF PAVEMENT ENGINEERING, 2022, 23 (08) :2728-2745
[10]   Impact of the current fluctuation on the efficiency of Alkaline Water Electrolysis [J].
Dobo, Zsolt ;
Palotas, Arpad Bence .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (09) :5649-5656