A novel repair method for the lifespan and performance improvement of a shell-and-tube heat exchanger: A thermo-mechanical approach

被引:0
作者
Delibas, Hulusi [1 ]
Yilmaz, Ibrahim Halil [1 ]
机构
[1] Adana Alparslan Turkes Sci & Technol Univ, Dept Mech Engn, Adana, Turkiye
关键词
Shell-and-tube heat exchanger; Damaged tube; Repair method; Thermo-mechanical model; THERMAL CONTACT CONDUCTANCE; INTERFACE; DESIGN; RESISTANCE;
D O I
10.1016/j.engfailanal.2025.109333
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Heat exchangers play a critical role in the functioning of many engineering systems. Shell-and-tube heat exchangers (STHEs) are more traditional and widely used devices due to their efficiency, versatility, and ability to handle a range of flow conditions and fluid types. STHEs experience a number of problems over time, including corrosion, mechanical wear, or leaking, and thus need repairs to keep operating. This study has introduced a novel repair approach for extending the lifespan of damaged STHE tubes by fitting new tubes. An original thermo-mechanical model, including the analyses of the STHE, thermal contact resistance between the fitted tubes, and mechanical design of the built structures, is proposed for the problem solution, and all governing equations are simultaneously solved in Engineering Equation Solver (EES). All submodels are validated with analytical or experimental data, and good agreements are obtained. The most significant design parameters and their effects on the thermal and mechanical performances of an STHE are parametrically investigated. Results reveal that increasing the contact surface slope over 10 degrees but lowering the effective surface roughness below 3 mu m provides an advantage for keeping the heat load of the STHE high. Among the interference fits, the locational interference fit is the most advantageous in terms of thermal and mechanical performances relative to other fit conditions. Both increasing operating pressure and tube diameter are two key pillars that can allow for a safety factor > 1.5. Fitting tube materials are parametrically independent and applicable to any STHE tube diameter as the yield strength > 300 MPa. Even if all tubes are press-fitted, the maximum heat load drop in the current repair method corresponds to 4.23 % which is lower than the tolerable value i.e., <10 % of the initially planned heat load.
引用
收藏
页数:16
相关论文
共 48 条
  • [21] Irreversibility features of a shell-and-tube heat exchanger fitted with novel trapezoidal oblique baffles: Application of a nanofluid with different particle shapes
    Bahiraei, Mehdi
    Naseri, Mohammad
    Monavari, Ali
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 126
  • [22] Double-pass shell-and-tube heat exchanger performance enhancement with new combined baffle and elliptical tube bundle arrangement
    Arani, Ali Akbar Abbasian
    Uosofvand, Hamed
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2021, 167
  • [23] Thermal storage performance of a novel shell-and-tube latent heat storage system: Active role of inner tube improvement and fin distribution optimization
    Li, Xiuzhen
    Chen, Sen
    Tan, Yingying
    Tian, Guo
    Wang, Zhanwei
    Tang, Songzhen
    Wang, Lin
    RENEWABLE ENERGY, 2024, 228
  • [24] Transient Thermo-mechanical analysis of a shell and tube latent heat thermal energy storage for CSP plants
    Riahi, Soheila
    Evans, Michael
    Belusko, Martin
    Flewell-Smith, Ross
    Jacob, Rhys
    Bruno, Frank
    APPLIED THERMAL ENGINEERING, 2021, 196 (196)
  • [25] Thermo-hydraulic rating of a shell and tube heat exchanger for acetone cooling using bell-delaware method
    Sanchez, Amaury Perez
    Julian, Alicia Maria Gomez
    Rodriguez, Nadia Corpas
    Gonzalez, Elizabeth Ranero
    Sanchez, Eddy Javier Perez
    NEXO REVISTA CIENTIFICA, 2023, 36 (04): : 524 - 550
  • [26] Numerical study on impact behavior of nanoparticle shapes on the performance improvement of shell and tube heat exchanger
    Hajabdollahi, Hassan
    Hajabdollahi, Zahra
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 125 : 449 - 460
  • [27] Effect of helical diameter on the performance of shell and helical tube heat exchanger: An experimental approach
    Rahimi, M.
    Hosseini, M. J.
    Gorzin, M.
    SUSTAINABLE CITIES AND SOCIETY, 2019, 44 : 691 - 701
  • [28] Thermal design and performance evaluation of a shell-and-tube heat exchanger using LNG cold energy in LNG fuelled ship
    Lim, Tae-Woo
    Choi, Yong-Seok
    APPLIED THERMAL ENGINEERING, 2020, 171
  • [29] Shell-and-tube heat exchangers performance improvement employing hybrid segmental–helical baffles and ribbed tubes combination
    Hamed Uosofvand
    Ali Akbar Abbasian Arani
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2021, 43
  • [30] Problems involved in the shell-side performance of a longitudinal-flow shell-and-tube heat exchanger with decrease in L/D and its solutions
    Zeng, Wen-Liang
    Zhang, Zheng-Guo
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2012, 7 (04) : 310 - 317