Design strategies for building rooftop photovoltaic systems: Efficiency and grid integration

被引:0
|
作者
Serat, Zainullah [1 ,2 ]
Chen, Xin [3 ]
Zuo, Hongyang [3 ]
Li, Jun [3 ]
机构
[1] Huazhong Univ Sci & Technol, China EU Inst Clean & Renewable Energy, 1037 Luoyu Rd, Wuhan 430074, Hubei, Peoples R China
[2] Ghazni Tech Univ, Fac Electromech, Dept Energy Engn, Ghazni 2301, Afghanistan
[3] Huazhong Univ Sci & Technol, State Key Lab Coal Combust, 1037 Luoyu Rd, Wuhan 430074, Hubei, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2025年 / 100卷
关键词
Building rooftop photovoltaic; Design strategies; Performance analysis; Monocrystalline silicon; Polycrystalline silicon; Thin-film; PERFORMANCE ANALYSIS; TECHNOECONOMIC FEASIBILITY; PV SYSTEM; TECHNOLOGIES; OPTIMIZATION;
D O I
10.1016/j.jobe.2024.111693
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In response to global environmental concerns and rising energy demands, this study evaluates photovoltaic (PV) technologies for designing efficient building rooftop PV systems and promoting sustainable energy integration. The research combines weather data from NREL and NASA to enhance the precision of performance analysis using PVsyst software, adhering to IEC-61724 standards. This dual-source approach ensures a robust assessment of PV system reliability across diverse climates. Building rooftop installation capacities are evaluated with PVSOL software, while HOMER Pro performs system configuration analyses. Results indicate that monocrystalline silicon (m-Si) outperforms polycrystalline silicon (p-Si) and thin-film technologies, Specifically, m-Si achieves an annual array yield of 5.61 kWh/kWp/day and 5.37 kWh/kWp/day, final yields of 5.47 kWh/kWp/day and 5.24 kWh/kWp/day, capacity factors of 17.9 % and 17.2 %, and performance ratios of 84.3 % and 86.7 %, respectively. Strategic building rooftop PV planning, taking into account roof area, tilt angle, and spacing, identifies an optimal capacity of 0.05 kW/m2. HOMER Pro recommends a grid-connected 5.03 kW PV system with a 4-kWh battery and 3.54 kW inverter, achieving a cost of energy (COE) of USD 0.0465/kWh. Sensitivity analysis reveals that higher solar irradiance reduces energy costs, while increased electric loads raise them. This study introduces a novel methodology for integrating dual-source weather data and advanced software tools to evaluate and optimize PV systems, providing practical insights for sustainable building rooftop PV installations and advancing renewable energy solutions.
引用
收藏
页数:34
相关论文
共 50 条
  • [21] An Optimized Strategy for the Integration of Photovoltaic Systems and Electric Vehicles into the Real Distribution Grid
    Kljajic, Ruzica
    Maric, Predrag
    Misljenovic, Nemanja
    Dubravac, Marina
    ENERGIES, 2024, 17 (22)
  • [22] Measured performance of a 1.72 kW rooftop grid connected photovoltaic system in Ireland
    Ayompe, L. M.
    Duffy, A.
    McCormack, S. J.
    Conlon, M.
    ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (02) : 816 - 825
  • [23] Efficiency Analysis of Grid-connected Photovoltaic Power Plants
    Markovic, Milan L. J.
    Ciric, Rade M.
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2017, 3 (03): : 269 - 277
  • [24] Design And Control Strategies of Quasi - Z Source Inverter For Photovoltaic Power Generation Systems
    Ramya, R.
    Sivakumaran, T. S.
    2020 5TH INTERNATIONAL CONFERENCE ON DEVICES, CIRCUITS AND SYSTEMS (ICDCS' 20), 2020, : 262 - 266
  • [25] Sustainability assessment of rooftop solar photovoltaic systems: A case study
    Malode, Satyajit
    Prakash, Ravi
    Mohanta, Jagadish Chandra
    ENVIRONMENTAL IMPACT ASSESSMENT REVIEW, 2024, 108
  • [26] Energy efficiency evaluation of building integrated photovoltaic systems with different power configurations
    Liu, Bangyin
    Duan, Shanxu
    SIMULATION MODELLING PRACTICE AND THEORY, 2012, 29 : 93 - 108
  • [27] Real-time prediction models for output power and efficiency of grid-connected solar photovoltaic systems
    Su, Yan
    Chan, Lai-Cheong
    Shu, Lianjie
    Tsui, Kwok-Leung
    APPLIED ENERGY, 2012, 93 : 319 - 326
  • [28] Single-Phase Rooftop Photovoltaic based Grid-Interactive Electricity System
    Kushwaha, P. C.
    Bhende, C. N.
    2016 IEEE ANNUAL INDIA CONFERENCE (INDICON), 2016,
  • [29] Methodology for the Sizing of Grid-connected Photovoltaic Systems
    Rostegui, Guido
    Salles, Mauricio B. C.
    Gemignani, Matheus
    2018 IEEE 7TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION (WCPEC) (A JOINT CONFERENCE OF 45TH IEEE PVSC, 28TH PVSEC & 34TH EU PVSEC), 2018, : 1225 - 1230
  • [30] Monitoring and checking of performance in photovoltaic plants: A tool for design, installation and maintenance of grid-connected systems
    Spertino, Filippo
    Corona, Fabio
    RENEWABLE ENERGY, 2013, 60 : 722 - 732