Feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated vascular closure device

被引:0
|
作者
Tachi, Masaya [1 ,2 ]
Tanaka, Akihito [1 ]
Teraoka, Tsubasa [2 ]
Furuta, Tappei [2 ]
Matsushita, Etsushi [2 ]
Hayashi, Kazunori [2 ]
Shimojo, Masafumi [1 ]
Yanagisawa, Satoshi [1 ]
Inden, Yasuya [1 ]
Murohara, Toyoaki [1 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Cardiol, 65 Tsurumai Cho,Showa Ku, Nagoya 4668560, Japan
[2] Nakatugawa Municipal Hosp, Dept Cardiol, Nakatugawa, Japan
关键词
VCD; Vascular closure device; Venous closure; Ultrasound guidance; Ablation; AORTIC-ANEURYSM REPAIR; ATRIAL-FIBRILLATION; CATHETER ABLATION; PERCUTANEOUS ACCESS; TRIAL; COMPLICATIONS; INTERVENTION; COMPRESSION; MULTICENTER; GUIDANCE;
D O I
10.1016/j.hrthm.2024.04.041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Venous vascular access complications are usually nonfatal but are the most common complications after trans- venous catheter intervention. Vascular closure devices (VCDs) have recently become available for venous closure. OBJECTIVE This study aimed to evaluate the feasibility and efficacy of real-time ultrasound-guided venous closure with suture- mediated VCDs in patients who underwent catheter ablation. METHODS This single-center observational study enrolled 226 consecutive patients who underwent elective catheter ablation with femoral venipuncture. For hemostasis, vessel closure by VCD was performed with real-time ultrasound guidance after 2022 (n = 123) and without ultrasound guidance in 2021 (n = 103). The occurrence of venous access site-related complications (major, minor, or other) was compared. RESULTS The rate of device failure was significantly lower in patients with ultrasound guidance than in those without (1.6% vs 6.3%; P = . 048). The occurrence of all venous access site-related complications was significantly lower in patients with ultrasound guidance than in those without (4.9% vs 18.4%; P = . 001). Time to ambulation was shorter in patients with ultrasound guidance than in those without (2.0 +/- 0.1 hours vs 2.2 +/- 0.6 hours; P < .001). CONCLUSION Real-time ultrasound guidance can reduce device failure, access site-related complications, and time to ambulation in performing venous closure with a VCD.
引用
收藏
页码:2028 / 2036
页数:9
相关论文
共 50 条
  • [31] Safety and efficacy of clip-based vs. suture mediated vascular closure for femoral access hemostasis: A prospective randomized single center study comparing the StarClose and the ProGlide device
    Klein-Wiele, Oliver
    Baliota, Maria
    Kara, Kaffer
    Kaeunicke, Matthias
    Schaefer, Harald
    Garbrecht, Marc
    Abdulghafor, Marwan
    Garmer, Marietta
    Hailer, Birgit
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 91 (03) : 402 - 407
  • [32] Real-time ultrasound-guided external intracerebral hemorrhage drain placement
    Cong Feng
    Sai Huang
    Li Chen
    Xuan Zhou
    Li-Li Wang
    Fa-Qin Lv
    Tan-Shi Li
    Military Medical Research, 7
  • [33] Safety and Effectiveness of Suture-mediated Arterial Closure Device in Hepatocellular Carcinoma Patients Who Underwent Drug-Eluting Beads Transarterial Chemoembolization
    De Fina, Bruna
    Nasser, Felipe
    Cavalcante, Rafael N.
    Campos, Carlos A.
    Galastri, Francisco L.
    Affonso, Breno B.
    Wolosker, Nelson
    Perin, Marco A.
    ANNALS OF VASCULAR SURGERY, 2019, 55 : 203 - 209
  • [34] Early sheath removal after coronary artery interventions with use of a suture-mediated closure device: Clinical outcome and results of Doppler US evaluation
    Wetter, DR
    Rickli, H
    von Smekal, A
    Amann, FW
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (08) : 1033 - 1037
  • [35] Autonomous Trajectory Planning for Ultrasound-Guided Real-Time Tracking of Suspicious Breast Tumor Targets
    Tan, Jiyong
    Li, Jiawang
    Li, Yuanwei
    Li, Bing
    Leng, Yuquan
    Rong, Yiming
    Fu, Chenglong
    IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2024, 21 (03) : 2478 - 2493
  • [36] Computer tomography urography assisted real-time ultrasound-guided percutaneous nephrolithotomy on renal calculus
    Fang, You-Qiang
    Wu, Jie-Ying
    Li, Teng-Cheng
    Zheng, Hao-Feng
    Liang, Guan-Can
    Chen, Yan-Xiong
    Hong, Xiao-Bin
    Cai, Wei-Zhong
    Zang, Zhi-Jun
    Di, Jin-Ming
    MEDICINE, 2017, 96 (24)
  • [37] Real-time ultrasound-guided paramedian spinal anaesthesia: evaluation of the efficacy and the success rate of single needle pass
    Chong, S. E.
    Nikman, A. Mohd
    Saedah, A.
    Nazaruddin, W. H. Wan Mohd
    Kueh, Y. C.
    Lim, J. A.
    Kamalrujan, H. Shamsul
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (05) : 799 - 801
  • [38] Real-time ultrasound-guided epidural catheter placement in infants: a case series
    Kamal, Manoj
    Kumar, Mritunjay
    Bihani, Pooja
    Mital, Tanya
    Singariya, Geeta
    Bhatia, Pradeep
    BRAZILIAN JOURNAL OF ANESTHESIOLOGY, 2024, 74 (05):
  • [39] Real-time ultrasound-guided stellate ganglion block for migraine: an observational study
    Hou, Jiawei
    Pu, Shaofeng
    Xu, Xingguo
    Lu, Zhiqiang
    Wu, Junzhen
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [40] Real-time ultrasound-guided stellate ganglion block for migraine: an observational study
    Jiawei Hou
    Shaofeng Pu
    Xingguo Xu
    Zhiqiang Lu
    Junzhen Wu
    BMC Anesthesiology, 22