Feasibility and efficacy of real-time ultrasound-guided venous closure with suture-mediated vascular closure device

被引:0
|
作者
Tachi, Masaya [1 ,2 ]
Tanaka, Akihito [1 ]
Teraoka, Tsubasa [2 ]
Furuta, Tappei [2 ]
Matsushita, Etsushi [2 ]
Hayashi, Kazunori [2 ]
Shimojo, Masafumi [1 ]
Yanagisawa, Satoshi [1 ]
Inden, Yasuya [1 ]
Murohara, Toyoaki [1 ]
机构
[1] Nagoya Univ, Grad Sch Med, Dept Cardiol, 65 Tsurumai Cho,Showa Ku, Nagoya 4668560, Japan
[2] Nakatugawa Municipal Hosp, Dept Cardiol, Nakatugawa, Japan
关键词
VCD; Vascular closure device; Venous closure; Ultrasound guidance; Ablation; AORTIC-ANEURYSM REPAIR; ATRIAL-FIBRILLATION; CATHETER ABLATION; PERCUTANEOUS ACCESS; TRIAL; COMPLICATIONS; INTERVENTION; COMPRESSION; MULTICENTER; GUIDANCE;
D O I
10.1016/j.hrthm.2024.04.041
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Venous vascular access complications are usually nonfatal but are the most common complications after trans- venous catheter intervention. Vascular closure devices (VCDs) have recently become available for venous closure. OBJECTIVE This study aimed to evaluate the feasibility and efficacy of real-time ultrasound-guided venous closure with suture- mediated VCDs in patients who underwent catheter ablation. METHODS This single-center observational study enrolled 226 consecutive patients who underwent elective catheter ablation with femoral venipuncture. For hemostasis, vessel closure by VCD was performed with real-time ultrasound guidance after 2022 (n = 123) and without ultrasound guidance in 2021 (n = 103). The occurrence of venous access site-related complications (major, minor, or other) was compared. RESULTS The rate of device failure was significantly lower in patients with ultrasound guidance than in those without (1.6% vs 6.3%; P = . 048). The occurrence of all venous access site-related complications was significantly lower in patients with ultrasound guidance than in those without (4.9% vs 18.4%; P = . 001). Time to ambulation was shorter in patients with ultrasound guidance than in those without (2.0 +/- 0.1 hours vs 2.2 +/- 0.6 hours; P < .001). CONCLUSION Real-time ultrasound guidance can reduce device failure, access site-related complications, and time to ambulation in performing venous closure with a VCD.
引用
收藏
页码:2028 / 2036
页数:9
相关论文
共 50 条
  • [1] Real-time ultrasound-guided hemostasis using suture-mediated closure device
    Kwak, JungWon
    Bum Cho, Sung
    JOURNAL OF VASCULAR ACCESS, 2025, 26 (01) : 228 - 233
  • [2] Collagen-Based Vascular Closure Device Multicenter Italian Experience in Endovascular Aortic Aneurysm Repair Compared With Suture-Mediated Closure Vascular Device
    Panagrosso, Marco
    Cavallo, Eduardo
    Bracale, Umberto Marcello
    Peluso, Antonio
    Silvestri, Olga
    Intrieri, Francesco
    Molinari, Vincenzo
    Esposito, Antonio
    Trimarchi, Santi
    Settembrini, Alberto Maria
    Lomazzi, Chiara
    La Barbera, Gaetano
    Carbonari, Luciano
    Angelini, Andrea
    Morelli, Irene
    Centonza, Eleonora
    Berchiolli, Raffaella
    Troisi, Nicola
    Scarati, Valentina
    Artini, Valerio
    De Vivo, Salvatore
    Volpe, Pietro
    Massara, Mafalda
    Martelli, Eugenio
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [3] Iatrogenic stenosis following suture-mediated closure device
    Tam, J.
    Given, M.
    Lutjen, P.
    Thomson, K.
    Lyon, S.
    AUSTRALASIAN RADIOLOGY, 2007, 51 : B319 - B323
  • [4] Analysis of Determinants for Suture-mediated Closure Device Failure During EVAR Procedures
    Garabet, W.
    Arnautovic, A.
    Meurer, L.
    Mulorz, J.
    Rembe, J. D.
    Duran, M.
    Suess, J. D.
    Schelzig, H.
    Wagenhaeuser, M. U.
    VASCULAR AND ENDOVASCULAR SURGERY, 2024, 58 (02) : 129 - 135
  • [5] Ultrasonographic assessment and clinical outcomes after deployment of a suture-mediated femoral vascular closure device
    Papoutsis, Dimitrios
    Mourouzis, Konstantinos
    Bozini, Nikoleta
    Aznaouridis, Konstantinos
    Oikonomou, Evangelos
    Chatzimichael, Katerina
    Brountzos, Elias
    Vavuranakis, Manolis
    Tsioufis, Costas
    Lekakis, John
    Siasos, Gerasimos
    Tousoulis, Dimitris
    CARDIOVASCULAR JOURNAL OF AFRICA, 2023,
  • [6] Safety and efficacy of suture-mediated closure after percutaneous coronary interventions
    Rinder, MR
    Tamirisa, PK
    Taniuchi, M
    Kurz, HI
    Mumm, K
    Lasala, JM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (02) : 146 - 151
  • [7] Infected pseudoaneurysm caused by suture-mediated vascular closure after ablation of atrial fibrillation: A case report
    Sakamoto, Yusuke
    Hiroyuki, Osanai
    Yoshida, Eiji
    Arai, Kenji
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2025, 127
  • [8] Comparison of manual compression, Z-stitch, and suture-mediated vascular closure device techniques in dogs undergoing percutaneous transvenous intervention
    Fabella, A.
    Markovic, L. E.
    Coleman, A. E.
    JOURNAL OF VETERINARY CARDIOLOGY, 2024, 51 : 124 - 137
  • [9] Feasibility and clinical benefit of a suture-mediated closure device for femoral vein access after percutaneous edge-to-edge mitral valve repair
    Geis, Nicolas A.
    Pleger, Sven T.
    Chorianopoulos, Emmanuel
    Mueller, Oliver J.
    Katus, Hugo A.
    Bekeredjian, Raffi
    EUROINTERVENTION, 2015, 10 (11) : 1346 - 1353
  • [10] Ultrasound-Guided Versus Conventional MANTA Vascular Closure Device Deployment After Transcatheter Aortic Valve Implantation
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Dahlbacka, Sebastian
    Vahasilta, Tommi
    Vainikka, Tiina
    Jalanko, Mikko
    Viikila, Juho
    Laine, Mika
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 180 : 116 - 123