An Energy-Efficient Real-Time Wearable ECG Acquisition System With Near-Data Prediagnosis for Mobile Applications

被引:0
作者
Choi, Seung Hun [1 ]
Kang, Minil [1 ]
Kwon, Kon-Woo [2 ]
Seok Kim, Jin Seok [3 ]
Jung, Jin-Man [4 ]
Lee, Hyung-Min [1 ]
机构
[1] Korea Univ, Sch Elect Engn, Seoul 02841, South Korea
[2] Hongik Univ, Dept Comp Engn, Seoul 04066, South Korea
[3] Korea Univ, Ansan Hosp, Coll Med, Dept Cardiol, Ansan 15355, South Korea
[4] Korea Univ, Ansan Hosp, Coll Med, Dept Neurol, Ansan 15355, South Korea
基金
新加坡国家研究基金会;
关键词
Electrocardiography; Monitoring; Wearable devices; Electrodes; Real-time systems; Batteries; Prototypes; Biomedical monitoring; Battery charge measurement; Arrhythmia; 3-lead electrocardiogram (ECG); battery lifetime; Bluetooth low energy (BLE); near-data processing; prediagnosis; real-time ECG acquisition system; telemedicine; wearable ECG device; CLASSIFICATION;
D O I
10.1109/TIM.2025.3547110
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we present an energy-efficient real-time electrocardiogram (ECG) acquisition system that utilizes near-data processing for prediagnosis and controls the frequency of wireless communication to reduce power consumption. The system consists of a wearable ECG monitoring device, an Android-based smartphone application, and a database server, which mitigate the inconvenience of the periodical visit to the hospital. To maximize the battery lifetime, the prototype wearable device adopted algorithms with near-data processing to enable prediagnosis, which was verified using the MIT-BIH arrhythmia database. Also, the real-time acquisition is available by the data transmission between the wearable device and the smartphone utilizing Bluetooth low energy (BLE) when the device starts collecting the patient's ECG data. The wearable device cannot only acquire the raw ECG waveform data but also provide an energy-saving option to send only feature data, which is processed within the device for near-data prediagnosis. The overall power consumption of the device was reduced because the power consumption by communication was greatly reduced. Measured results verified that the feature data transmission with near-data processing can increase the battery lifetime by 15.9% compared to the conventional raw ECG data transmission.
引用
收藏
页数:11
相关论文
共 42 条
  • [11] On the Einthoven Triangle: A Critical Analysis of the Single Rotating Dipole Hypothesis
    Gargiulo, Gaetano D.
    Bifulco, Paolo
    Cesarelli, Mario
    McEwan, Alistair L.
    Moeinzadeh, Hossein
    O'Loughlin, Aiden
    Shugman, Ibrahim M.
    Tapson, Jonathan C.
    Thiagalingam, Aravinda
    [J]. SENSORS, 2018, 18 (07)
  • [12] Gifari MW, 2015, 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS 2015, P371, DOI 10.1109/ICEEI.2015.7352529
  • [13] Gradl S, 2012, IEEE ENG MED BIO, P2452, DOI 10.1109/EMBC.2012.6346460
  • [14] Hargittai S, 2005, COMPUT CARDIOL, V32, P763
  • [16] Ioannou K., 2014, Bcmj, V56, P86
  • [17] How useful is the smartwatch ECG?
    Isakadze, Nino
    Martin, Seth S.
    [J]. TRENDS IN CARDIOVASCULAR MEDICINE, 2020, 30 (07) : 442 - 448
  • [18] Wearable Devices in Clinical Trials: Hype and Hypothesis
    Izmailova, Elena S.
    Wagner, John A.
    Perakslis, Eric D.
    [J]. CLINICAL PHARMACOLOGY & THERAPEUTICS, 2018, 104 (01) : 42 - 52
  • [19] Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
    Kiranyaz, Serkan
    Ince, Turker
    Gabbouj, Moncef
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (03) : 664 - 675
  • [20] Laudato G., 2021, Frontiers Hum. Dyn., V3, P1