Fault Detection and Fault Location in a Grid-Connected Microgrid Using Optimized Deep Learning Neural Network

被引:0
作者
Karthick, R. [1 ]
Saravanan, R. [2 ]
Arulkumar, P. [3 ]
机构
[1] SNS Coll Technol, Dept Elect & Elect Engn, Coimbatore, Tamilnadu, India
[2] Balaji Inst Technol & Sci, Dept Elect & Elect Engn, Warangal, Telangana, India
[3] VSB Engn Coll, Dept Elect & Elect Engn, Karur, Tamil Nadu, India
关键词
data processing; data set; deep learning; fault detection; microgrid; microgrid infrastructure; STRATEGY;
D O I
10.1002/oca.3237
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The significant prevalence of distributed energy resources in microgrids due to their unique characteristics and activities creates protection issues. This paper introduces fault detection and its location in an MG. The aim of the investigation is to enhance the system's efficiency and dependability, and fault detection and prediction are employed. Data are gathered from the operational Microgrid (MG) infrastructure dataset, and the data are fed to the Newton Time-Extracting Wavelet Transform (NTEWT). It cleanses the data and enhances the input data's quality. After the preprocessed data are fed to the feature extraction by using Distorted Gaussian Matched Filtering (DGMF), it extracts the five statistical features from the voltage signal. The optimal features are fed to the Deep Attention Dilated Residual Convolutional Neural Network (DADRCNN), which predicts the faults in the microgrid. The Dung Beetle Optimization (DBO) is utilized to optimize the weight parameter of DADRCNN. The MATLAB platform is utilized to implement the proposed method. The proposed method is contrasted with various existing approaches like Graph Convolutional Network and Graph Fourier Transform (GCN-GFT), Feed-Forward Neural Network and Back-Propagation Algorithm (FFNN-BPA), and Discrete Wavelet Transform and Radial Basis Function Neural Network (DWT-RBFN). The existing method shows a fault detection rate of 91.12, 88.80, and 84.239, and the proposed technique illustrates a fault detection rate of 99.9640, which is higher than other existing approaches. The existing method shows a false alarm rate of 0.758, 1.028, and 1.564, and the proposed technique shows a false alarm rate of 0.2519, which is lower than other existing methods. The proposed approach exhibits a reduced false alarm rate and a greater fault detection rate, it is concluded.
引用
收藏
页数:16
相关论文
共 22 条
  • [1] AlvaradoCarrillo D. E., 2021, Geometry and Vision, P378, DOI DOI 10.1007/978-3-030-72073-5_29
  • [2] Artificial Intelligence-Based Protection for Smart Grids
    Bakkar, Mostafa
    Bogarra, Santiago
    Corcoles, Felipe
    Aboelhassan, Ahmed
    Wang, Shuo
    Iglesias, Javier
    [J]. ENERGIES, 2022, 15 (13)
  • [3] An Intelligent Data Mining-Based Fault Detection and Classification Strategy for Microgrid
    Baloch, Shazia
    Muhammad, Mannan Saeed
    [J]. IEEE ACCESS, 2021, 9 : 22470 - 22479
  • [4] Integrating discrete wavelet transform with neural networks and machine learning for fault detection in microgrids
    Cano, Antonio
    Arevalo, Paul
    Benavides, Dario
    Jurado, Francisco
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 155
  • [5] A robust transient and sustainable faults location approach for AC microgrid based on voltage and current difference measurements
    Daisy, Mohammad
    Aliabadi, Mahmood Hosseini
    Javadi, Shahram
    Naimi, H. Meyar
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 153
  • [6] Espinoza JL, 2017, IEEE INT AUT MEET
  • [7] Fault Detection and Classification for Wide Area Backup Protection of Power Transmission Lines Using Weighted Extreme Learning Machine
    Harish, Ani
    Prince, A.
    Jayan, M., V
    [J]. IEEE ACCESS, 2022, 10 : 82407 - 82417
  • [8] Islanding detection and classification of non-islanding disturbance in multi-distributed generation power system using deep neural networks
    Hussain, Arif
    Mirza, Shakil
    Kim, Chul-Hwan
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2023, 224
  • [9] Newton time-extracting wavelet transform: An effective tool for characterizing frequency-varying signals with weakly-separated components and theoretical analysis
    Li, Wenting
    Auger, Francois
    Zhang, Zhuosheng
    Zhu, Xiangxiang
    [J]. SIGNAL PROCESSING, 2023, 209
  • [10] Fault logic and data-driven model for operation reliability analysis of the flap deflection angle
    Liu, Wan-Yi
    Feng, Yun-Wen
    Teng, Da
    Lu, Cheng
    Chen, Jun-Yu
    [J]. PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2023, 381 (2260):