The downstream purification of bispecific antibodies

被引:1
作者
Li, Qian [1 ]
Zhao, Hongyang [1 ]
Liang, Xiaoying [1 ]
He, Qingquan [1 ]
Wang, Zicheng [1 ]
Qin, Guohong [1 ]
Li, Guozhu [1 ]
Xu, Dan [1 ]
机构
[1] Nanjing Chia Tai Tianqing Pharmaceut Co Ltd, Fanghua Res Inst, Inst Biol, Nanjing 210046, Peoples R China
关键词
Bispecific antibody (bsAb); Capture chromatography; Product-related impurities; Process-related impurities; Removal strategies; MIXED-MODE CHROMATOGRAPHY; CELL PROTEIN CLEARANCE; ENDOTOXIN REMOVAL; EXCHANGE CHROMATOGRAPHY; CHROMATIN; IMPACT;
D O I
10.1016/j.ab.2024.115692
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bispecific antibodies, a class of therapeutic antibodies, can simultaneously bind to two distinct targets. Compared with monospecific antibodies, bispecific antibodies offer advantages, including superior efficacy and reduced side effects. However, because of their structural complexity, the purification of bispecific antibodies is highly challenging. The purification process must strike a delicate balance between purity and productivity, eliminating a broad spectrum of contaminants, including product-related and process-related impurities, while also maximizing the yield wherever feasible. This review systematically describes the strategies for bispecific antibody capture, the elimination of product-related impurities, and the mitigation of the formation of process-related impurities, thereby, providing guidance for the development of downstream purification processes for bispecific antibodies.
引用
收藏
页数:12
相关论文
共 80 条
  • [1] Capto MMC mixed-mode chromatography of murine and rabbit antibodies
    Arakawa, Tsutomu
    Kurosawa, Yasunori
    Storms, Michael
    Maruyama, Toshiaki
    Okumura, C. J.
    Kita, Yoshiko
    [J]. PROTEIN EXPRESSION AND PURIFICATION, 2016, 127 : 105 - 110
  • [2] Affinity chromatography: A versatile technique for antibody purification
    Arora, Sushrut
    Saxena, Vikas
    Ayyar, B. Vijayalakshmi
    [J]. METHODS, 2017, 116 : 84 - 94
  • [3] Clearance of the Rodent Retrovirus, XMuLV, by Protein A Chromatography
    Bach, Julia
    Connell-Crowley, Lisa
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 2015, 112 (04) : 743 - 750
  • [4] A short peptide fragment of the vascular endothelial growth factor as a novel ligand for bevacizumab purification
    Barredo, Gabriela R.
    Giudicessi, Silvana L.
    Martinez Ceron, Maria C.
    Saavedra, Soledad L.
    Rodriguez, Santiago
    Risso Lucas, Filgueira
    Erra-Balsells, Rosa
    Mahler, Gustavo
    Albericio, Fernando
    Cascone, Osvaldo
    Camperi, Silvia A.
    [J]. PROTEIN EXPRESSION AND PURIFICATION, 2020, 165
  • [5] Membrane Adsorber for the Fast Purification of a Monoclonal Antibody Using Protein A Chromatography
    Braemer, Chantal
    Tuennermann, Lisa
    Salcedo, Alina Gonzalez
    Reif, Oscar-Werner
    Solle, Doerte
    Scheper, Thomas
    Beutel, Sascha
    [J]. MEMBRANES, 2019, 9 (12)
  • [6] Monoclonal antibody purification and its progression to commercial scale
    Chahar, Digamber Singh
    Ravindran, Selvan
    Pisal, S. S.
    [J]. BIOLOGICALS, 2020, 63 : 1 - 13
  • [7] Chen Dayue, 2016, PDA J Pharm Sci Technol, V70, P443
  • [8] Recent development and application of membrane chromatography
    Chen, Jing
    Yu, Bing
    Cong, Hailin
    Shen, Youqing
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2023, 415 (01) : 45 - 65
  • [9] Effective flow-through polishing strategies for knob-into-hole bispecific antibodies
    Chen, Serene W.
    Hoi, Kong Meng
    Bin Mahfut, Farouq
    Yang, Yuansheng
    Zhang, Wei
    [J]. BIORESOURCES AND BIOPROCESSING, 2022, 9 (01)
  • [10] Excellent removal of knob-into-hole bispecific antibody byproducts and impurities in a single-capture chromatography
    Chen, Serene W.
    Hoi, Kong Meng
    Bin Mahfut, Farouq
    Yang, Yuansheng
    Zhang, Wei
    [J]. BIORESOURCES AND BIOPROCESSING, 2022, 9 (01)