Multi-resonant current controller for grid-tied inverters with LCL filters based on pole placement under robustness constraints

被引:0
|
作者
Stojic, Djordje M. [1 ]
Sekara, Tomislav B. [2 ]
机构
[1] Univ Belgrade, Nikola Tesla Inst, Belgrade, Serbia
[2] Univ Belgrade, Sch Elect Engn, Belgrade, Serbia
关键词
Anti-windup algorithm; Digital multi-resonant current controller; LCL-filtered grid-tied inverter; Pole placement; Reference response forming; Robust design; CONNECTED CONVERTERS; ANTIWINDUP;
D O I
10.1007/s43236-025-01016-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, a multi-resonant current controller for grid-connected inverters with LCL filters is presented with the aim of improving the dynamic performance and robustness of inverter systems. A pole placement technique is used to calculate the controller parameters, allowing the closed-loop poles to be precisely placed to achieve the required performance and robustness. A new feedforward reference response forming method is also proposed to improve the reference tracking capabilities of the controller, and a new anti-windup algorithm is proposed to avoid the performance deterioration caused by the saturation of the multi-resonant controller. The effectiveness of the proposed controller is demonstrated using simulation results that confirm its robustness to parameter changes and disturbances, as well as its effectiveness in terms of current tracking. The functionality of the controller is also tested with a prototype inverter system, and the test results are presented to confirm the effectiveness of the controller.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] New robust resonant current controller design for grid-tied inverters with LLCL filters
    Stojic, Djordje M.
    Sekara, Tomislav B.
    JOURNAL OF POWER ELECTRONICS, 2025,
  • [2] An Improved Observer-Based State Feedback Controller for Grid-Tied Inverters with LCL filters
    Benrabah, Abdeldjabar
    Khoucha, Farid
    Kheloui, Abdelaziz
    Raza, Ali
    Xu, Dianguo
    2019 INTERNATIONAL CONFERENCE ON ADVANCED ELECTRICAL ENGINEERING (ICAEE), 2019,
  • [3] Constraints on the Controller Bandwidth of Grid-tied Inverters
    du Plessis, Francois
    Beukes, Johan
    2023 25TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, EPE'23 ECCE EUROPE, 2023,
  • [4] Resonant Current Controller With Enhanced Transient Response for Grid-Tied Inverters
    Busada, Claudio A.
    Gomez Jorge, Sebastian
    Solsona, Jorge A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (04) : 2935 - 2944
  • [5] Current control strategy based on pole placement for grid-connected inverters with LCL filters
    Xu, J. (xjinming01@163.com), 1600, Automation of Electric Power Systems Press (38):
  • [6] An Adaptive Multi-Resonant Current Controller for a Single-Phase Grid-Tied Converter With Grid Disturbance Rejection Capability
    Kumar, Anup
    Aware, Mohan V.
    Umre, Bhimrao S.
    Waghmare, Manoj A.
    IEEE ACCESS, 2022, 10 : 28053 - 28065
  • [7] Damping for Multi - paralleled Grid Tied Inverters with LCL Filters
    Liang, Jiazhi
    Jiang, Jiuchun
    Ojo, Olorunfemi
    Haruna, Josiah
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 5879 - 5886
  • [8] UDE-Based Current Controller With Enhanced Grid Frequency Fluctuation Adaptability for LCL-Type Grid-Tied Inverters
    Xiong, Yongkang
    Ye, Yongqiang
    Zhu, Mingzhe
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (02) : 1683 - 1691
  • [9] Improved Resonant Current Controller for Grid-Tied Converters
    Perez-Estevez, Diego
    Doval-Gandoy, Jesus
    Yepes, Alejandro G.
    Lopez, Oscar
    Baneira, Fernando
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 3877 - 3884
  • [10] A Proportional plus Multi-Resonant Current Controller for Grid-connected Inverters under Unbalanced Grid Voltage
    Pan, Jiajin
    Liu, Yancheng
    Zhang, Qinjin
    Wang, Ning
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL WORKSHOP ON MATERIALS ENGINEERING AND COMPUTER SCIENCES (IWMECS 2015), 2015, 33 : 527 - 532