Ungated, plug-and-play preclinical cardiac CEST-MRI using radial FLASH with segmented saturation

被引:0
|
作者
Weigand-Whittier, Jonah [1 ]
Wendland, Michael [2 ]
Lam, Bonnie [1 ]
Velasquez, Mark [1 ]
Vandsburger, Moriel H. [1 ]
机构
[1] Univ Calif Berkeley, Dept Bioengn, 284 Hearst Mem Min, Berkeley, CA 94270 USA
[2] Univ Calif Berkeley, Berkeley Preclin Imaging Core, Berkeley, CA USA
关键词
cardiac imaging; chemical exchange saturation transfer; preclinical imaging; sequence design; MAGNETIZATION-TRANSFER; IN-VIVO; QUANTITATIVE DESCRIPTION; CONTRAST AGENTS; HEART-FAILURE; RESONANCE; SPECTROSCOPY; ASYMMETRY; CREATINE; ORIGINS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeElectrocardiography (ECG) and respiratory-gated preclinical cardiac CEST-MRI acquisitions are difficult because of variable saturation recovery with T1, RF interference in the ECG signal, and offset-to-offset variation in Z-magnetization and cardiac phase introduced by changes in cardiac frequency and trigger delays.MethodsThe proposed method consists of segmented saturation modules with radial FLASH readouts and golden angle progression. The segmented saturation blocks drive the system to steady-state, and because center k-space is sampled repeatedly, steady-state saturation dominates contrast during gridding and reconstruction. Ten complete Z-spectra were acquired in healthy mice using both ECG and respiratory-gated and ungated methods. Z-spectra were also acquired at multiple saturation B1 values to optimize for amide and Cr contrasts.ResultsThere was no significant difference between CEST contrasts (amide, Cr, magnetization transfer) calculated from images acquired using ECG and respiratory-gated and ungated methods (p = 0.27, 0.11, 0.47). A saturation power of 1.8 mu T provides optimal contrast amplitudes for both amide and total Cr contrast without significantly complicating CEST contrast quantification because of water direct saturation, magnetization transfer, and RF spillover between amide and Cr pools. Further, variability in CEST contrast measurements was significantly reduced using the ungated radial FLASH acquisition (p = 0.002, 0.006 for amide and Cr, respectively).ConclusionThis method enables CEST mapping in the murine myocardium without the need for cardiac or respiratory gating. Quantitative CEST contrasts are consistent with those obtained using gated sequences, and per-contrast variance is significantly reduced. This approach makes preclinical cardiac CEST-MRI easily accessible, even for investigators without prior experience in cardiac imaging.
引用
收藏
页数:14
相关论文
共 2 条
  • [1] Ungated, plug-and-play preclinical cardiac CEST-MRI using radial FLASH with segmented saturation
    Weigand-Whittier, Jonah
    Wendland, Michael
    Lam, Bonnie
    Velasquez, Mark
    Vandsburger, Moriel H.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1793 - 1806
  • [2] Segmented radial cardiac MRI during arrhythmia using retrospective electrocardiogram and respiratory gating
    Chava, Raghuram
    Assis, Fabrizio
    Herzka, Daniel
    Kolandaivelu, Aravindan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (03) : 1726 - 1738