Morphometric Analysis of the Neural Arch of C2 Vertebra in Indian Population

被引:0
作者
Varghese, Jija E. [1 ]
Rabi, Suganthy [1 ]
Joseph, Vivek [2 ]
Jeyaseelan, Lakshmanan [3 ]
Prithishkumar, Ivan J. [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Anat, Vellore 632004, Tamil Nadu, India
[2] Christian Med Coll & Hosp, Dept Neurosurg, Vellore, Tamil Nadu, India
[3] Christian Med Coll & Hosp, Dept Biostat, Vellore, Tamil Nadu, India
关键词
Lamina; pedicle screw; pediculoisthmic component; vertebral artery foramen; SCREW PLACEMENT; AXIS; FRACTURES; DIMENSIONS; ANATOMY;
D O I
10.4103/ni.ni_1033_22
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background and Objective: The most common injuries to upper cervical spine are fractures of the second cervical vertebrae. The study aims to evaluate the morphometry of the neural arch of the second cervical vertebrae in the South Indian population. Materials and Methods: Sixty-three second cervical vertebrae of undetermined gender and age without any gross defect were used for the study. The dimensions of neural arch, including superior articular facet, inferior articular facet, pediculoisthmic component, lamina, spinous process, foramen transversarium, and vertebral foramen, were measured by two independent observers using digital vernier caliper accurate to 0.1 mm and the data was analyzed. Descriptive statistics were obtained for the variables. Paired t-test was done to compare the measurements between right and left sides. Results: There was no statistical difference between the right and left sides of the dimensions of superior articular facets, foramen transversarium, and the transverse diameter of inferior articular facet. The anteroposterior diameter of the inferior articular facets was more on the right side (P = 0.009). The width of the pediculoisthmic component in both the superior and inferior aspects was found to be less on the right side than that of the left (P = 0.006 and P = 0.031, respectively). The thickness in the middle one-third of laminae was optimum for bilateral safe screw insertion (>= 4.0 mm) in 77% specimens. Conclusion: In summary, measurements of the transverse diameter of superior articular facet and thickness of lamina differed significantly from those reported in literature. This should be kept in mind while doing neurosurgery procedures in the Indian population.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
[31]   3D-printed Titanium Prosthetic Reconstruction of the C2 Vertebra Techniques and Outcomes of Three Consecutive Cases [J].
Hunn, Samuel A. M. ;
Koefman, Alex J. ;
Hunn, Andrew W. M. .
SPINE, 2020, 45 (10) :667-672
[32]   Computed tomography morphometric analysis of C2 translaminar screw fixation of Wright's technique and a modified technique in the pediatric cervical spine [J].
Xia, Dong-Dong ;
Lin, Sheng-Lei ;
Chen, Wei ;
Shen, Zhong-Hai ;
Li, Yao ;
Wang, Xiang-Yang ;
Xu, Hua-Zi ;
Chi, Yong-Long .
EUROPEAN SPINE JOURNAL, 2014, 23 (03) :606-612
[33]   Feasibility of C2 Lamina Screw Placement in a New Zealand Cohort: Computed Tomography Analysis According to Ethnicity and Gender [J].
Storey, Richard N. ;
Baker, Joseph F. .
INTERNATIONAL JOURNAL OF SPINE SURGERY, 2024, 18 (05) :471-476
[34]   C2-fractures: part I. Quantitative morphology of the C2 vertebra is a prerequisite for the radiographic assessment of posttraumatic C2-alignment and the investigation of clinical outcomes [J].
Heiko Koller ;
Frank Acosta ;
Mark Tauber ;
Elisabeth Komarek ;
Michael Fox ;
Mido Moursy ;
Wolfgang Hitzl ;
Herbert Resch .
European Spine Journal, 2009, 18 :978-991
[35]   Anatomical analysis of the C2 pedicle in patients with basilar invagination [J].
Ruipei Xiao ;
Juedong Hou ;
Yang Zhou ;
Jintao Zheng ;
Xiaobao Zou ;
Yongjian Zhu ;
Ling Yao ;
Xiangyang Ma ;
Jianting Chen ;
Jincheng Yang .
European Spine Journal, 2022, 31 :2684-2692
[36]   CT-guided vertebroplasty of first (C1) or second (C2) cervical vertebra using an electromagnetic navigation system and a transoral approach [J].
Moulin, Benjamin ;
Brisse, Herve ;
Dutertre, Guillaume ;
Brenet, Olivier ;
Queinnec, Marie ;
Cottu, Paul ;
Zadegan, Frederic ;
Moreau, Sebastien ;
Benchimol, Raphael ;
Cao, Kim ;
Servois, Vincent .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2021, 102 (09) :571-575
[37]   Anatomical analysis of the C2 pedicle in patients with basilar invagination [J].
Xiao, Ruipei ;
Hou, Juedong ;
Zhou, Yang ;
Zheng, Jintao ;
Zou, Xiaobao ;
Zhu, Yongjian ;
Yao, Ling ;
Ma, Xiangyang ;
Chen, Jianting ;
Yang, Jincheng .
EUROPEAN SPINE JOURNAL, 2022, 31 (10) :2684-2692
[38]   Spinal Cord Medial Safe Zone for C2 Pedicle Instrumentation An MRI Measurement Analysis [J].
Chiapparelli, Erika ;
Bowen, Edward ;
Okano, Ichiro ;
Salzmann, Stephan N. ;
Reisener, Marie-Jacqueline ;
Shue, Jennifer ;
Sama, Andrew A. ;
Cammisa, Frank P. ;
Girardi, Federico P. ;
Hughes, Alexander P. .
SPINE, 2022, 47 (03) :E101-E106
[39]   Surgical outcomes of traumatic C2 body fractures: a retrospective analysis [J].
Pasham, Amarendra ;
Mudumba, Vijaya S. ;
Alugolu, Rajesh .
JOURNAL OF NEUROSURGICAL SCIENCES, 2023, 67 (02) :150-156
[40]   Anterior pedicle screw fixation of C2: an anatomic analysis of axis morphology and simulated surgical fixation [J].
Zeng-Hui Wu ;
Yi Zheng ;
Qing-Shui Yin ;
Xiang-Yang Ma ;
Yi-Hong Yin .
European Spine Journal, 2014, 23 :356-361