Comparative Investigating of Absorption and Sensitivity Parameters in Ammonia Gas Sensors Based on Conducting Polymers

被引:0
|
作者
Aarabi, Mokhtar [1 ]
Kashaninia, Alireza [1 ]
Sarbazi, Hamed [2 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Cent Tehran Branch, Tehran, Iran
[2] Islamic Azad Univ, Islamshahr Branch, Dept Elect Engn, Islamshahr, Iran
关键词
Gas sensor; conductive polymer; adsorption; sensitivity; Langmuir adsorption model;
D O I
10.1142/S0219581X24500297
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In this work, we have investigated and compared three important parameters: resistance, absorbance, and sensitivity of the sensitive layer in the ammonia gas sensor made of conductive polymers. Using a simulation based on the Langmuir absorption model, we have examined the changes in resistance, absorbance, and sensitivity of both the pure conducting polymer and the layer doped with carbon nanotubes. We analyzed the results using Matlab software. The findings demonstrate that the addition of carbon nanotubes reduces the resistance and enhances the absorbance and sensitivity.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Enhanced sensitivity of graphene ammonia gas sensors using molecular doping
    Zanjani, Seyedeh Maryam Mortazavi
    Sadeghi, Mir Mohammad
    Holt, Milo
    Chowdhury, Sk. Fahad
    Tao, Li
    Akinwande, Deji
    APPLIED PHYSICS LETTERS, 2016, 108 (03)
  • [22] Chemical Biological Sensors Based on Advances in Conducting Electroactive Polymers
    Omowunmi A. Sadik
    Miriam Ngundi
    Adam Wanekaya
    Microchimica Acta, 2003, 143 : 187 - 194
  • [23] Biomimetic quartz crystal sensors for caffeine based on conducting polymers
    Ebarvia, Benilda S.
    Sevilla, Fortunato, III
    2005 Asian Conference on Sensors and the International Conference on New Techniques in Pharmaceutical and Biomedical Research, Proceedings, 2005, : 34 - 38
  • [24] Chemical biological sensors based on advances in conducting electroactive polymers
    Sadik, OA
    Ngundi, M
    Wanekaya, A
    MICROCHIMICA ACTA, 2003, 143 (2-3) : 187 - 194
  • [25] MWCNT-conducting polymer composite based ammonia gas sensors: A new approach for complete recovery process
    Sharma, Sakshi
    Hussain, Shahir
    Singh, Sukhvir
    Islam, S. S.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 : 213 - 219
  • [26] Novel array-type gas sensors using conducting polymers, and their performance for gas identification
    Sakurai, Y
    Jung, HS
    Shimanouchi, T
    Inoguchi, T
    Morita, S
    Kuboi, R
    Natsukawa, K
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 83 (1-3): : 270 - 275
  • [27] INTEGRATED ARRAYS OF GAS SENSORS USING CONDUCTING POLYMERS WITH MOLECULAR-SIEVES
    SHURMER, HV
    CORCORAN, P
    GARDNER, JW
    SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (1-2) : 29 - 33
  • [28] Conducting polymer-based nanostructures for gas sensors
    Liu, Xianghong
    Zheng, Wei
    Kumar, Rahul
    Kumar, Mahesh
    Zhang, Jun
    COORDINATION CHEMISTRY REVIEWS, 2022, 462
  • [29] Ammonia sensors manufactured by plasma enhanced grafting of conducting polymers on nylon-6 fabrics
    Nimbekar, Ashish A.
    Bhatia, Pushpinder G.
    Deshmukh, Rajendrasing R.
    SYNTHETIC METALS, 2021, 279
  • [30] Bibliometric analysis on conducting polymer sensors for ammonia gas detection using Scopus database
    Baharin, Siti Nor Atika
    Zain, Zainiharyati Mohd
    Zolekafeli, Zulhatiqah
    Mehmood, Shahid
    Sambasevam, Kavirajaa Pandian
    VIETNAM JOURNAL OF CHEMISTRY, 2024, 62 (03) : 399 - 411