Raman Spectroscopy Combined with Partial Least Squares for Quantitative Analysis of Two Kinds of Microplastics in Water Samples

被引:0
|
作者
Ding, Jian-Ming [1 ,2 ]
Wang, Xin [1 ]
Zhang, Rong-Ling [1 ]
Zhou, Li-Yuan [1 ]
Zhang, Tian-Long [1 ]
Tang, Hong-Sheng [1 ]
Li, Hua [3 ]
机构
[1] Northwest Univ, Coll Chem & Mat Sci, Key Lab Synthet & Nat Funct Mol Chem, Minist Educ, Xian 710127, Peoples R China
[2] Inst Hyg Ordnance Ind, Xian 710065, Peoples R China
[3] Xian Shiyou Univ, Coll Chem & Chem Engn, Xian 710065, Peoples R China
基金
中国国家自然科学基金;
关键词
Microplastics; Partial least squares; Raman spectroscopy; Chemometrics; FEATURE-SELECTION; PARTICLES; PLS;
D O I
10.19756/j.issn.0253-3820.241260
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics (MPs) are emerging contaminants in aquatic environments characterized by their polar structure, small particle size (Typically less than 5 mm), large surface area, good stability, and resistance to biodegradation. They pose adverse effects on the normal physiological activities of aquatic organisms and can accumulate in biota, including humans. Therefore, there is an urgent need for rapid and accurate quantitative analysis of MPs in water environments. In this study, Raman spectroscopy combined with partial least squares (PLS) was employed for rapid and accurate quantitative analysis of polyethylene (PE) and polystyrene (PS) MPs in real water samples. Initially, 33 simulated water samples containing different concentrations of MPs were prepared, and their Raman spectra were collected. Six spectral preprocessing methods (Normalization, multiplicative scatter correction, standard normal variate transformation, first derivative, second derivative, and wavelet transform) were investigated for their impact on the predictive performance of PLS calibration models. Subsequently, three variable selection methods including synergy interval partial least squares (SiPLS), variable importance in projection (VIP) and mutual information (MI) were employed to optimize the input variables of the PLS calibration model. The predictive capability of the PLS calibration model was evaluated and validated using leave-one-out cross- validation. Under the optimal conditions of spectral preprocessing, variable selection, input variables and latent variables, the wavelet transform-partial least squares (WT-PLS) calibration model based on distilled water was established, and the contents of PE and PS in real water samples were predicted with prediction correlation coefficients (R2p) of 0.9540 and 0.8472 for PE and PS, respectively, and prediction errors (Errorp) of 0.0690 and 0.1126, respectively. Furthermore, a mixed sample MI-PLS calibration model was developed, demonstrating the best predictive performance in real water samples (With R 2 p values of 0.9776 and 0.9755 for PE and PS, respectively, and Errorp values of 0.0360 and 0.0392, respectively). This method provided a novel approach and new methodology for quantitative analysis of MPs and other organic pollutants in real water samples.
引用
收藏
页码:1581 / 1590
页数:10
相关论文
共 50 条
  • [31] Detection of the site of phosphorylation in a peptide using Raman spectroscopy and partial least squares discriminant analysis
    Zhang, DM
    Ortiz, C
    Xie, Y
    Davisson, VJ
    Ben-Amotz, D
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2005, 61 (03) : 471 - 475
  • [32] Differentiation of Gasoline Samples Using Flame Emission Spectroscopy and Partial Least Squares Discriminate Analysis
    de Paulo, Jaqueline M.
    Barros, Jose E. M.
    Barbeira, Paulo J. S.
    ENERGY & FUELS, 2014, 28 (07) : 4355 - 4361
  • [33] Quantitative analysis of polycyclic aromatic hydrocarbons in soil by infrared spectroscopy combined with hybrid variable selection strategy and partial least squares
    Li, Maogang
    Feng, Yaozhou
    Yu, Yan
    Zhang, Tianlong
    Yan, Chunhua
    Tang, Hongsheng
    Sheng, Qinglin
    Li, Hua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 257
  • [34] Raman spectroscopy combined with partial least squares (PLS) based on hybrid spectral preprocessing and backward interval PLS (biPLS) for quantitative analysis of four PAHs in oil sludge
    Ma, Changfei
    Zhai, Lulu
    Ding, Jianming
    Liu, Yanli
    Hu, Shunfan
    Zhang, Tianlong
    Tang, Hongsheng
    Li, Hua
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 310
  • [35] Simultaneous spectrophotometric determination of four metals by two kinds of partial least squares methods
    Gao, L
    Ren, SX
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2005, 61 (13-14) : 3013 - 3019
  • [36] Determination of florfenicol by Raman spectroscopy with principal component analysis (PCA) and partial least squares regression (PLSR)
    Ali, Zain
    Nawaz, Haq
    Majeed, Muhammad Irfan
    Rashid, Nosheen
    Mohsin, Mashkoor
    Raza, Ali
    Shakeel, Muhammad
    Ali, Muhammad Zeeshan
    Sabir, Amina
    Shahbaz, Muhammad
    Ehsan, Usama
    ul Hasan, Hafiz Mahmood
    ANALYTICAL LETTERS, 2024, 57 (01) : 30 - 40
  • [37] Artificial neural networks (ANNs) and partial least squares (PLS) regression in the quantitative analysis of cocrystal formulations by Raman and ATR-FTIR spectroscopy
    Barmpalexis, P.
    Karagianni, A.
    Nikolakakis, I.
    Kachrimanis, K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 214 - 224
  • [38] On the discrimination between facial creams of different brands using Raman Spectroscopy and partial least squares discriminant analysis for forensic application
    Asri, Muhammad Naeim Mohamad
    Verma, Rajesh
    Ibrahim, Muhammad Haffizzan
    Nor, Nor Azman Mohd
    Sharma, Vishal
    Ismail, Dzulkiflee
    SCIENCE & JUSTICE, 2021, 61 (06) : 687 - 696
  • [39] Probabilistic Partial Least Square Regression: A Robust Model for Quantitative Analysis of Raman Spectroscopy Data
    Li, Shuo
    Gao, Jean
    Nyagilo, James O.
    Dave, Digant P.
    2011 IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICINE (BIBM 2011), 2011, : 526 - 531
  • [40] Rapid identification of milk samples by high and low frequency unfolded partial least squares discriminant analysis combined with near-infrared spectroscopy
    Bian, Xihui
    Zhang, Caixia
    Liu, Peng
    Wei, Junfu
    Tan, Xiaoyao
    Lin, Ligang
    Chang, Na
    Guo, Yugao
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2017, 170 : 96 - 101