Raman Spectroscopy Combined with Partial Least Squares for Quantitative Analysis of Two Kinds of Microplastics in Water Samples

被引:0
|
作者
Ding, Jian-Ming [1 ,2 ]
Wang, Xin [1 ]
Zhang, Rong-Ling [1 ]
Zhou, Li-Yuan [1 ]
Zhang, Tian-Long [1 ]
Tang, Hong-Sheng [1 ]
Li, Hua [3 ]
机构
[1] Northwest Univ, Coll Chem & Mat Sci, Key Lab Synthet & Nat Funct Mol Chem, Minist Educ, Xian 710127, Peoples R China
[2] Inst Hyg Ordnance Ind, Xian 710065, Peoples R China
[3] Xian Shiyou Univ, Coll Chem & Chem Engn, Xian 710065, Peoples R China
基金
中国国家自然科学基金;
关键词
Microplastics; Partial least squares; Raman spectroscopy; Chemometrics; FEATURE-SELECTION; PARTICLES; PLS;
D O I
10.19756/j.issn.0253-3820.241260
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microplastics (MPs) are emerging contaminants in aquatic environments characterized by their polar structure, small particle size (Typically less than 5 mm), large surface area, good stability, and resistance to biodegradation. They pose adverse effects on the normal physiological activities of aquatic organisms and can accumulate in biota, including humans. Therefore, there is an urgent need for rapid and accurate quantitative analysis of MPs in water environments. In this study, Raman spectroscopy combined with partial least squares (PLS) was employed for rapid and accurate quantitative analysis of polyethylene (PE) and polystyrene (PS) MPs in real water samples. Initially, 33 simulated water samples containing different concentrations of MPs were prepared, and their Raman spectra were collected. Six spectral preprocessing methods (Normalization, multiplicative scatter correction, standard normal variate transformation, first derivative, second derivative, and wavelet transform) were investigated for their impact on the predictive performance of PLS calibration models. Subsequently, three variable selection methods including synergy interval partial least squares (SiPLS), variable importance in projection (VIP) and mutual information (MI) were employed to optimize the input variables of the PLS calibration model. The predictive capability of the PLS calibration model was evaluated and validated using leave-one-out cross- validation. Under the optimal conditions of spectral preprocessing, variable selection, input variables and latent variables, the wavelet transform-partial least squares (WT-PLS) calibration model based on distilled water was established, and the contents of PE and PS in real water samples were predicted with prediction correlation coefficients (R2p) of 0.9540 and 0.8472 for PE and PS, respectively, and prediction errors (Errorp) of 0.0690 and 0.1126, respectively. Furthermore, a mixed sample MI-PLS calibration model was developed, demonstrating the best predictive performance in real water samples (With R 2 p values of 0.9776 and 0.9755 for PE and PS, respectively, and Errorp values of 0.0360 and 0.0392, respectively). This method provided a novel approach and new methodology for quantitative analysis of MPs and other organic pollutants in real water samples.
引用
收藏
页码:1581 / 1590
页数:10
相关论文
共 50 条
  • [1] Probabilistic partial least squares regression for quantitative analysis of Raman spectra
    Li, Shuo
    Nyagilo, James O.
    Dave, Digant P.
    Wang, Wei
    Zhang, Baoju
    Gao, Jean
    INTERNATIONAL JOURNAL OF DATA MINING AND BIOINFORMATICS, 2015, 11 (02) : 223 - 243
  • [2] Application of Raman Spectroscopy Combined With Partial Least Squares Method in Rapid Quantitative Analysis of Diesel n-Butanol
    Ma Zhong-kai
    Li Mao-gang
    Yan Chun-hua
    Liu Hao-sen
    Tao Shu-hao
    Tang Hong-sheng
    Zhang Tian-long
    Li Hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2023, 43 (07) : 2153 - 2157
  • [3] Quantitative Analysis of Simulated Illicit Street-Drug Samples Using Raman Spectroscopy and Partial Least Squares Regression
    Fenton, Owen S.
    Tonge, Lindsey A.
    Moot, Taylor H.
    Frederick, Kimberley A.
    SPECTROSCOPY LETTERS, 2011, 44 (04) : 229 - 234
  • [4] Quantification of polydimethylsiloxane concentration in turbid samples using raman spectroscopy and the method of partial least squares
    A. J. Durkin
    M. N. Ediger
    G. H. Pettit
    Lasers in Medical Science, 1998, 13 : 32 - 41
  • [5] Simultaneous Detection of Lutein and β-Carotene in Tobacco by Using Raman Spectroscopy Combined with Partial Least Squares
    Ge Jiong
    Sun Lin
    Shen Xiao-jie
    Sha Yun-fei
    HuangT ian-xiong
    Du Yi-ping
    Zhang Wei-bing
    Xie Wen-yan
    Yao He-ming
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2019, 39 (11) : 3519 - 3524
  • [6] Quantitative analysis of mixed hydrofluoric and nitric acids using Raman spectroscopy with partial least squares regression
    Kang, Gumin
    Lee, Kwangchil
    Park, Haesung
    Lee, Jinho
    Jung, Youngjean
    Kim, Kyoungsik
    Son, Boongho
    Park, Hyoungkuk
    TALANTA, 2010, 81 (4-5) : 1413 - 1417
  • [7] A Modified Least-Squares Method for Quantitative Analysis in Raman Spectroscopy
    Bai, Yanru
    Yuen, Clement
    Liu, Quan
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2021, 27 (04)
  • [8] An improved partial least-squares regression method for Raman spectroscopy
    Monfared, Ali Momenpour Tehran
    Anis, Hanan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 185 : 98 - 103
  • [9] The quality control of two Pueraria species using Raman spectroscopy coupled with partial least squares analysis
    Wong, Ka H.
    Razmovski-Naumovski, Valentina
    Li, Kong M.
    Li, George Q.
    Chan, Kelvin
    JOURNAL OF RAMAN SPECTROSCOPY, 2015, 46 (04) : 361 - 368
  • [10] Study on Rapid Quantitative Analysis Method of Methanol Content in Methanol Gasoline by Raman Spectroscopy and Partial Least Squares
    Li Mao-gang
    Yan Chun-hua
    Du Yao
    Zhang Tian-long
    Li Hua
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2021, 41 (07) : 2099 - 2104