Experimental and numerical studies on fire resistance of damaged traditional mortise-tenon jointed timber frames

被引:0
|
作者
Lu, Yu [1 ,3 ]
Song, Xiaobin [1 ,2 ]
Peng, Yiqing [1 ]
Zhang, Baozhuang [1 ,2 ]
Chen, Yunxiao [1 ]
机构
[1] Tongji Univ, Coll Civil Engn, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Tongji Univ, Key Lab Performance Evolut & Control Engn Struct, Minist Educ, Shanghai 200092, Peoples R China
[3] Minist Housing & Urban Rural Dev Republ China, Beijing 100835, Peoples R China
来源
JOURNAL OF BUILDING ENGINEERING | 2025年 / 103卷
基金
中国国家自然科学基金; 中国博士后科学基金; 上海市自然科学基金;
关键词
Traditional timber structures; Mortise-tenon jointed timber frame; Looseness; Decay; Fire resistance; Sequentially coupled thermo-mechanical anal-ysis; Degradation mechanism; BEHAVIOR;
D O I
10.1016/j.jobe.2025.112213
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The looseness and decay damage in mortise-tenon (M&T) joints are commonly seen in the traditional timber frame, severely threatening the safety and fire resistance of traditional timber structures. To study the influence of deterioration to M&T joint on the fire resistance of traditional timber frame, we fabricated four 1/1.14-scaled traditional M&T jointed timber frame specimens, two without damage, one considering the looseness to joint, and one considering the decay of joint. The static loading test for one intact timber frame was carried out at normal temperature. Based on this, fire resistance tests of the specimens with different types of damage and 30 % fire load ratio were conducted under ISO 834 fire exposure. The failure mode, section temperature distribution, and wood charring rate of the frames after being exposed to fire were obtained, and the influence mechanism of damage to M&T joint on the fire resistance was revealed. The results indicated that the joint damage would remarkably change the failure mode and reduce the fire endurance; The non-damaged specimen experienced the joint failure after being exposed to fire for 55.5 min, while the specimens with the looseness and decay of joint suffered the bending failure at the mid span of the beam after being exposed to fire for 28.3 and 33.2 min, respectively. Furthermore, the heat transfer and sequentially coupled thermomechanical analysis models of the traditional timber frames consider the joint's damage were developed and verified using the test results. The parametric analyses were also performed to analyze the effects of different fire load ratios, loose and decay degree of the joint on the fire resistance of the timber frame. It is found that the model predictions were in good agreement with the test results. When the fire exposure time was constant, with an increase in the fire load ratio and the joint's looseness degree, the bending stiffness of the beam and joint's rotational stiffness of the timber frame significantly decreased. With an increase in the fire load ratio and the degree of looseness and decay, and the fire endurance of the frame decreased. When the fire load ratio decreased from 30 % to 10 %, the fire endurance of the frame increased by 26 %; Conversely, when the fire load ratio increased to 60 %, the fire endurance reduced by 48 %. Compared to non- damaged condition, when the looseness degree of joint in the frame was 22 %, the fire endurance of the frame reduced by up to 70 %; With a decay degree of joint in the frame of 22 %, the fire endurance of the frame reduced by up to 60 %.
引用
收藏
页数:22
相关论文
共 23 条
  • [1] Experimental study on fire resistance of traditional timber mortise-tenon joints with damages
    Song, Xiao-bin
    Zhang, Yu
    Lu, Yu
    Peng, Yi-qing
    Zhou, Haizhu
    FIRE SAFETY JOURNAL, 2023, 138
  • [2] Experimental study on fire resistance of post-beam timber frames with traditional mortise-tenon joints with damage
    Gao, Yuan
    Song, Xiao-bin
    Peng, Yi-qing
    ENGINEERING STRUCTURES, 2025, 333
  • [3] Experimental Study on the Traditional Timber Mortise-Tenon Joints
    Li, Xiaowei
    Zhao, Junhai
    Ma, Guowei
    Huang, Shuanghua
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (12) : 2089 - 2102
  • [4] Experimental Study on Wooden Pin Reinforcement of the Typical Mortise-Tenon Joints of Ancient Timber Frames
    Ren, Quanchang
    Liang, Bin
    Zhou, Yan
    Liu, Ge
    Yang, Yanan
    Lu, Liqiang
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024,
  • [5] Sequentially coupled thermal-stress analysis of traditional timber mortise-tenon joints with damage
    Song, Xiaobin
    Lu, Yu
    Peng, Yiqing
    Zhang, Yu
    Zhou, Haizhu
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [6] Lateral Performance of Traditional Heavy Timber Frames with Mortise-Tenon Joints Retrofitted Using Self-Tapping Screws
    Song, Xiaobin
    Li, Kai
    Crayssac, Emile
    Wu, Yajie
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (10)
  • [7] Analysis on mechanical behavior of dovetail mortise-tenon joints with looseness in traditional timber buildings
    Li, Yizhu
    Cao, Shuangyin
    Xue, Jianyang
    STRUCTURAL ENGINEERING AND MECHANICS, 2016, 60 (05) : 903 - 921
  • [8] Effects of gaps on the seismic performance of traditional timber frames with straight mortise-tenon joint: Experimental tests, energy dissipation mechanism and hysteretic model
    Zhang, Baozhuang
    Xie, Qifang
    Liu, Yijin
    Zhang, Lipeng
    Li, Shengying
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [9] Experimental and numerical studies on influences of wedge reinforcement on seismic performance of loose penetrated mortise-tenon joints
    He, Junxiao
    Liu, Ke
    Xie, Linlin
    Wang, Xiangjin
    Yang, Wenyi
    Zhao, Wenlong
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [10] The Influence of the Damage of Mortise-Tenon Joint on the Cyclic Performance of the Traditional Chinese Timber Frame
    Sha, Ben
    Wang, Hao
    Li, Aiqun
    APPLIED SCIENCES-BASEL, 2019, 9 (16):