Incidence and risk factors of medical adhesive-related skin injuries in outpatients with peripherally inserted central catheters

被引:0
|
作者
Xia, Qi [1 ]
Chen, Xin [2 ]
Ma, Qinghua [3 ]
Zhang, Dingding [4 ]
机构
[1] Sichuan Acad Med Sci & Sichuan Prov Peoples Hosp, Dept PICC, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Resp & Crit Illness, Chengdu, Peoples R China
[3] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Nursing, Chengdu, Peoples R China
[4] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Sichuan Prov Key Lab Genet Dis, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
MARSI; PICC; Tension injury; Outpatient; PREVENTION; GUIDELINES; DAMAGE;
D O I
10.1016/j.jtv.2025.100875
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Aims: Skin exposed to the adhesives to protect catheters is prone to Medical Adhesive-Related Skin Injuries (MARSI). Occurrence of these injuries and the risk factors have not been estimated previously in outpatients with peripherally inserted central catheters. The primary aim of this study was to delineate the characteristics of MARSI and quantify 3 types of incidence rates of MARSI among outpatients with PICC placements. Methods: The study sample included 299 outpatients with PICC placements from October to December 2020. The data were collected at the Sichuan Academy of Medical Sciences&Sichuan Provincial People's Hospital in Chengdu, China.A three-month cross-sectional survey was conducted at the PICC center of a tertiary general hospital in Western China to analyze the occurrence of MARSI at the catheterization site and related factors. Professional nurses observed and assessed skin conditions during catheter maintenance and collected patient data that could be associated with MARSI occurrence. The relationship between independent variables and MARSI was statistically analyzed using multivariate analysis. Results: Among outpatients with peripherally inserted central catheters,the incidence rate of MARSI was 14.7 %. Statistical analysis revealed that maintenance personnel (chi 2 = 8.683, P = 0.003), MARSI history (chi 2 = 4.332, P = 0.037), external fixation devices (chi 2 = 4.227, P = 0.04) were significantly associated with the occurrence of MARSI. Moreover, patients over the age of 50 (chi 2 = 4.183, P = 0.041) and the use of transparent dressing (chi 2 = 6.782, P = 0.009) were found to be associated with tension injuries. A multivariate analysis showed that the use of external fixation devices (OR, 2.987; 95 % CI, 1.044 to 8.547; P = 0.041) was an independent risk factor for MARSI. Conclusions: Patients with PICC in the outpatient department are at a high risk of developing MARSI. To prevent and control MARSI,it is essential to enhance the professional skills of maintenance staff and to pay special attention to patients with a history of MARSI and those over the age of 50. Additionally,the use of external fixation devices and transparent dressings should also be considered.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Exchange of Peripherally Inserted Central Catheters is Associated with an Increased Risk for Bloodstream Infection
    McCoy, Michael
    Bedwell, Susan
    Noori, Shahab
    AMERICAN JOURNAL OF PERINATOLOGY, 2011, 28 (06) : 419 - 423
  • [32] Complications with peripherally inserted central catheters (PICCs) used in hospitalized patients and outpatients: a prospective cohort study
    Grau, Delphine
    Clarivet, Beatrice
    Lotthe, Anne
    Bommart, Sebastien
    Parer, Sylvie
    ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2017, 6
  • [33] Lower risk of bloodstream infections for peripherally inserted central catheters compared to central venous catheters in critically ill patients
    Pitiriga, Vassiliki
    Bakalis, John
    Theodoridou, Kalliopi
    Kanellopoulos, Petros
    Saroglou, George
    Tsakris, Athanasios
    ANTIMICROBIAL RESISTANCE AND INFECTION CONTROL, 2022, 11 (01)
  • [34] Pediatric peripherally inserted central catheters: Complication rates related to catheter tip location
    Racadio, JM
    Doellman, DA
    Johnson, ND
    Bean, JA
    Jacobs, BR
    PEDIATRICS, 2001, 107 (02) : art. no. - e28
  • [35] Incidence and risk factors of neonatal peripherally inserted central catheter-related thrombosis: A systematic review and meta-analysis
    Chen, Xiuwen
    Yue, Liqing
    Liao, Peng
    Li, Bingyu
    NURSING IN CRITICAL CARE, 2025, 30 (02)
  • [36] Incidence of Deep Vein Thrombosis Associated with Peripherally Inserted Central Catheters in Adults with Cystic Fibrosis
    Nash, Edward F.
    Helm, Emma J.
    Stephenson, Anne
    Tullis, Elizabeth
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (03) : 347 - 351
  • [37] The Risk of Bloodstream Infection Associated with Peripherally Inserted Central Catheters Compared with Central Venous Catheters in Adults: A Systematic Review and Meta-Analysis
    Chopra, Vineet
    O'Horo, John C.
    Rogers, Mary A. M.
    Maki, Dennis G.
    Safdar, Nasia
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2013, 34 (09) : 908 - 918
  • [38] Risk factors for peripherally inserted central venous catheter-related complications in children: A retrospective cohort study
    Wang, Fang
    Wang, Yu
    Liu, Jingzhen
    MEDICINE, 2023, 102 (39) : E34924
  • [39] Risk factors and clinical analysis of peripherally inserted central catheter-related fungal colonization in premature infants
    Zhang, Lingping
    Yang, Liu
    Dong, Wenbin
    Liu, Xingling
    Lei, Xiaoping
    Zhang, Lianyu
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] High risk of deep vein thrombosis associated with peripherally inserted central catheters in lymphoma
    Zhang, Xi
    Huang, Jia-Jia
    Xia, Yi
    Li, Chao-Feng
    Wang, Yu
    Liu, Pan-Pan
    Bi, Xi-Wen
    Sun, Peng
    Lin, Tong-Yu
    Jiang, Wen-Qi
    Li, Zhi-Ming
    ONCOTARGET, 2016, 7 (23) : 35404 - 35411