Sensitive and Fast Simultaneous Voltammetric Determination of Dopamine and Uric Acid Using Simple Screen-Printed Carbon Electrode Without Pretreatment and Modification

被引:0
|
作者
Niaz, Abdul [1 ,2 ]
Arain, Muhammad Balal [1 ,3 ]
Soylak, Mustafa [1 ,4 ,5 ]
机构
[1] Erciyes Univ, Fac Sci, Dept Chem, Kayseri, Turkiye
[2] Univ Sci & Technol, Dept Chem, Bannu, Kpk, Pakistan
[3] Univ Karachi, Dept Chem, Karachi, Pakistan
[4] Erciyes Univ, Technol Res & Applicat Ctr ERU TAUM, Kayseri, Turkiye
[5] Turkish Acad Sci TUBA, Ankara, Turkiye
关键词
dopamine; lower electrolyte concentration; simultaneous determination; unmodified screen-printed carbon electrode; uric acid; urine sample; ASCORBIC-ACID; ELECTROCHEMICAL DETECTION; NANOTUBES; SENSORS;
D O I
10.1002/elan.12001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple, commercially available, unmodified screen-printed carbon electrode (SPCE) was investigated for the simultaneous voltammetric determination of dopamine (D/A) and uric acid (U/A) in a medium of very low concentration of supporting electrolyte for the first time. The ordinary, simple SPCE from DropSens (DS-SPCE) was found to be able to separate the overlapping peaks of D/A and U/A with a wide peak potential separation of 300 mV in a medium of very low concentration (0.001 M) of NaH2PO4 as supporting electrolyte (buffer of low capacity) at pH 8.0. Medium of low concentration of electrolyte made it possible to expose the bare electrode surface for its high catalytic activity which resulted into a high peak current signals, particularly for D/A. The DS-SPCE showed excellent electrocatalytic performance than the other SPCE. The effect of electrolyte concentration and pH on the electrocatalytic behavior of electrode were thoroughly discussed. The DS-SPCE displayed a sensitive results in good linear ranges from 0.1-5 to 6-20 mu M for D/A and 0.5-41.5 mu M for U/A. The disposable electrode demonstrated better discrimination ability toward the detection of D/A and U/A over ascorbic acid and other potential interfering species. Moreover, the sensor presented sensitive and highly accurate results in human urine samples without preliminary treatment. The DS-SPCE sensor was found to be simple, efficient, fast, low cost, and greener than the other reported modified sensors, while providing better sensitivities to detect D/A and U/A simultaneously. Thus, the bare, unmodified DS-SPCE can be a convenient sensing device for the routine analysis of D/A and U/A, without requiring any complex pretreatment and modification steps of the electrode.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Voltammetric behavior and trace determination of cadmium at a calixarene modified screen-printed carbon electrode
    Honeychurch, KC
    Hart, JP
    Cowell, DC
    Arrigan, DWM
    ELECTROANALYSIS, 2002, 14 (03) : 177 - 185
  • [32] Simple and Sensitive Determination of Sibutramine in Slimming Tea Beverages Using a Carbon Screen-printed Electrode with Adsorptive Stripping Voltammetry
    Lima, Amanda B.
    dos Santos, Wallans T. P.
    Compton, Richard G.
    ELECTROANALYSIS, 2019, 31 (05) : 975 - 980
  • [33] Simultaneous determination of maltose and glucose using a screen-printed electrode system
    Ge, F
    Zhang, XE
    Zhang, ZP
    Zhang, XM
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4): : 333 - 339
  • [34] Voltammetric determination of uric acid using a miniaturized platform based on screen-printed electrodes modified with platinum nanoparticles
    Gomes-Junior, Paulo Cardoso
    Nascimento, Evair Dias
    Augusto, Karen Kenlderi de Lima
    Longatto, Gustavo Patelli
    Faria, Ronaldo Censi
    Piccin, Evandro
    Fatibello-Filho, Orlando
    MICROCHEMICAL JOURNAL, 2024, 207
  • [35] Simultaneous electrochemical detection of ascorbic acid, dopamine and uric acid using Au decorated carbon nanofibers modified screen printed electrode
    Sakthivel, P.
    Ramachandran, K.
    Maheshvaran, K.
    Senthil, T. S.
    Manivel, P.
    CARBON LETTERS, 2024, 34 (09) : 2325 - 2341
  • [36] Laser-activated screen-printed carbon electrodes for enhanced dopamine determination in the presence of ascorbic and uric acid
    Alba, Alejandro Fidel
    Totoricaguena-Gorriño, Joseba
    Sánchez-Ilárduya, María Belén
    Ruiz-Rubio, Leire
    Vilas-Vilela, José Luis
    Lanceros-Méndez, Senentxu
    del Campo, Francisco Javier
    del Campo, Francisco Javier (Javier.delcampo@bcmaterials.net), 1600, Elsevier Ltd (399):
  • [37] Laser-activated screen-printed carbon electrodes for enhanced dopamine determination in the presence of ascorbic and uric acid
    Fidel Alba, Alejandro
    Totoricaguena-Gorrino, Joseba
    Belen Sanchez-Ilarduya, Maria
    Ruiz-Rubio, Leire
    Luis Vilas-Vilela, Jose
    Lanceros-Mendez, Senentxu
    Javier del Campo, Francisco
    ELECTROCHIMICA ACTA, 2021, 399
  • [38] Single-Drop Analysis of Epinephrine and Uric Acid on a Screen-Printed Carbon Electrode
    Majer, David
    Finsgar, Matjaz
    BIOSENSORS-BASEL, 2021, 11 (08):
  • [39] Fabrication of a fast, simple and sensitive voltammetric sensor for the simultaneous determination of 4-aminohippuric acid and uric acid using a functionalized multi-walled carbon nanotube modified glassy carbon electrode
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    Ahmadi, Farzaneh
    ANALYTICAL METHODS, 2012, 4 (06) : 1825 - 1832
  • [40] Amperometric Determination of Dopamine Using Activated Screen-Printed Carbon Electrodes
    Pan, Deng
    Rong, Shengzhong
    Zhang, Guangteng
    Zhang, Yannan
    Zhou, Qiang
    Liu, Fenghai
    Li, Miaojing
    Chang, Dong
    Pan, Hongzhi
    ELECTROCHEMISTRY, 2015, 83 (09) : 725 - 729