A Multivariable Sensing System for Condition Monitoring of Oil-Immersed Transformers

被引:0
|
作者
Wani, Shufali Ashraf [1 ]
Sarathi, Ramanujam [1 ]
Subramanian, Venkatachalam [2 ]
机构
[1] IIT Madras, Dept Elect Engn, Chennai 600036, India
[2] IIT Madras, Dept Phys, Chennai 600036, India
关键词
Sensors; Oils; Oil insulation; Power transformer insulation; Sensor arrays; Moisture; Chemical sensors; Capacitive sensors; Optical fiber sensors; Monitoring; Calibration; insulation degradation; multivariable sensing; real-time condition monitoring; selectivity; simultaneous quantification; SENSORS;
D O I
10.1109/JSEN.2025.3538157
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transformers are critical to electrical grids, making continuous monitoring of their condition essential. Transformer health is conventionally monitored through oil quality. Advances in monitoring can be achieved by focusing on quantifying species released during oil degradation. However, no existing technology quantifies these degradation markers simultaneously. Our goal was to develop sensing technology for these markers that meets key criteria: coexistent quantification and compatibility with transformer systems. We present a high-performance microwave sensor designed for efficient oil quality signal acquisition, coupled with a novel computational model for simultaneous quantification of degradation markers. Modified coaxial cable-based resonator working on multivariable response principles acts as a sensing device. It guarantees concurrent information about the oil and paper insulation conditions by quantifying moisture and 2-furfuraldehyde (2-FAL) simultaneously. Sensor performance is realized in terms of sensitivity, selectivity, repeatability, and limit of detection studies. Multivariable sensors are compact alternative to sensor arrays with reduced drift, minimized size, and lower costs. The use of microwave sensors for multivariable sensing is novelly reported, and their application in a transformer monitoring scenario is paramount owing to high stability. The proposed computational model can significantly facilitate the discriminative power of physical multivariable sensors by mitigating their selectivity issue.
引用
收藏
页码:9708 / 9717
页数:10
相关论文
共 50 条
  • [1] A study on deterioration evaluation method by condition monitoring and diagnosis for aging oil-immersed power transformers
    Chang, Jeong-Ho
    Lee, Sung-Hun
    Lee, Heung-Ho
    Transactions of the Korean Institute of Electrical Engineers, 2014, 63 (02): : 297 - 305
  • [2] Implementation of a Condition Monitoring Software for Mineral Oil-Immersed Transformers via Dissolved Gas In-Oil Analysis
    Torres, Jorge
    Guerrero, Jose M.
    Leones, Wilson
    Platero, Carlos A.
    2021 21ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2021 5TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC/I&CPS EUROPE), 2021,
  • [3] Fiber Bragg Grating Sensors for Temperature monitoring in Oil-Immersed Transformers
    Jiang, Yi
    Liu, Shuang
    Xiao, Li
    Li, Wei
    2016 15TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS AND NETWORKS (ICOCN), 2016,
  • [4] Evaluation of the Cooling System Calculation Technique for Oil-Immersed Transformers
    Dmitrieva, O. S.
    Patrakova, G. R.
    Dmitriev, A., V
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [5] Oil-Immersed Power Transformer Condition Monitoring Methodologies: A Review
    Jin, Lan
    Kim, Dowon
    Abu-Siada, Ahmed
    Kumar, Shantanu
    ENERGIES, 2022, 15 (09)
  • [6] Condition Monitoring of Oil-immersed Transformers Using AI Edge Inference for Incipient Fault Prediction: A case study
    Odongo, George Yogo
    Musabe, Richard
    Hanyurwimfura, Damien
    Diwani, Abubakar
    2022 IEEE PES/IAS POWERAFRICA CONFERENCE, 2022, : 540 - 544
  • [7] Cooling System Oil-Immersed Transformers with the Use of a Circulating Sulfur Hexafluoride
    Bashirov, M. G.
    Khismatullin, A. S.
    Sirotina, E., V
    ADVANCES IN AUTOMATION, 2020, 641 : 613 - 621
  • [8] Assessment of the Health Condition of Oil-Immersed Transformers Using Logistic Regression and Poisson Distribution
    Areffin, Sultanul
    Bhuiyan, Mohammed Imamul Hasan
    Chowdhury, Aongti
    2017 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL INFORMATION AND COMMUNICATION TECHNOLOGY (EICT 2017), 2017,
  • [9] THE DEVELOPMENT OF AN OIL-IMMERSED SURGE ARRESTER FOR DISTRIBUTION TRANSFORMERS
    MCMILLEN, CJ
    COMBER, MG
    HOPKINSON, RH
    SCHOENDUBE, CW
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (09): : 2482 - 2491