Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

被引:1
|
作者
Keliskova, Pavlina [1 ]
Matvieiev, Oleksandr [1 ]
Jirouskova, Eliska [2 ]
Sokolova, Romana [2 ]
Janikova, Lenka [1 ]
Behul, Miroslav [3 ]
Selesovska, Renata [1 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Guaifenesin; Screen-printed sensor; Boron-doped diamond electrode; Voltammetry; Flow injection analysis with electrochemical detection; Spectroelectrochemistry; MULTIWALLED CARBON NANOTUBE; MASS-SPECTROMETRY METHOD; GAS-CHROMATOGRAPHY; PARACETAMOL; PHENYLEPHRINE; HYDROCHLORIDE; SULFATE; COUGH; SERUM; CELL;
D O I
10.1016/j.talanta.2024.126809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton- Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L-1), a wide linear dynamic range (LDR = 0.1-155 mu mol L-1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 mu L) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L-1, LDR = 0.1-50 mu mol L-1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF SILDENAFIL CITRATE (VIAGRA®) IN PHARMACEUTICAL FORMULATIONS USING A BORON-DOPED DIAMOND ELECTRODE
    Batista, Erica Ferreira
    Sartori, Elen Romao
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ANALYTICAL LETTERS, 2010, 43 (06) : 1046 - 1054
  • [42] Electrochemical Behaviour of Ofloxacin in Pharmaceutical and Biological Samples Using a Boron-Doped Diamond Electrode in Using Anionic Surfactant
    Talay Pinar, Pinar
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2018, 31 (01): : 66 - 80
  • [43] Evaluation of boron-doped diamond electrode for simultaneous voltammetric determination of hydrochlorothiazide and losartan in pharmaceutical formulations
    Gardenal Santos, Michely Cristina
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrique
    Sartori, Elen Romao
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 263 - 270
  • [44] Voltammetric Behaviour of Rhodamine B at a Screen-Printed Carbon Electrode and Its Trace Determination in Environmental Water Samples
    Honeychurch, Kevin C.
    SENSORS, 2022, 22 (12)
  • [45] Electrochemical evaluation and voltammetric determination of laxative drug bisacodyl on boron-doped diamond electrode
    Falone, Max Fabricio
    Rossi Salamanca-Neto, Carlos Alberto
    Moraes, Jaqueline Tobias
    Sartori, Elen Romao
    MEASUREMENT, 2019, 137 : 464 - 469
  • [46] Simple and rapid voltammetric determination of cephalosporin drug cefixime on boron-doped diamond electrode
    Ertuğrul Keskin
    Shabnam Allahverdiyeva
    Hamza Seker
    Yavuz Yardım
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 1895 - 1902
  • [47] A New Electrochemical Sensor for the Detection of Azithromycin using Screen-Printed Carbon Electrode Modified with Boron-Doped Diamond Nanoparticles and Reduced-Graphene Oxide
    Jiwanti, Prastika K.
    Insani, Shafa A.
    Sari, Anis P.
    Wafiroh, Siti
    CHEMISTRYSELECT, 2024, 9 (21):
  • [48] Determination of Colchicine in Pharmaceutical Formulations and Urine by Multiple-Pulse Amperometric Detection in an FIA System Using Boron-Doped Diamond Electrode
    Moreira, Debora A. R.
    de Oliveira, Fernando M.
    Pimentel, Dilton M.
    Guedes, Tiago J.
    Luz, Rita C. S.
    Damos, Flavio S.
    Pereira, Arnaldo C.
    da Silva, Rodrigo A. B.
    dos Santos, Wallans T. P.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2018, 29 (09) : 1796 - 1802
  • [49] Voltammetric quantification of the anesthetic drug propofol (2,6-diisopropylphenol) in pharmaceutical formulations on a boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Ozok, Hande Izem
    Yunusoglu, Oruc
    Yardim, Yavuz
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2021, 86 (7-8) : 711 - 724
  • [50] Voltammetric behavior of rutin at a boron-doped diamond electrode. Its electroanalytical determination in a pharmaceutical formulation
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (10): : 1674 - 1681