Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

被引:1
|
作者
Keliskova, Pavlina [1 ]
Matvieiev, Oleksandr [1 ]
Jirouskova, Eliska [2 ]
Sokolova, Romana [2 ]
Janikova, Lenka [1 ]
Behul, Miroslav [3 ]
Selesovska, Renata [1 ]
机构
[1] Univ Pardubice, Inst Environm & Chem Engn, Fac Chem Technol, Studentska 573, Pardubice 53210, Czech Republic
[2] Czech Acad Sci, J Heyrovsky Inst Phys Chem, Dolejskova 3, Prague 18223, Czech Republic
[3] Slovak Univ Technol Bratislava, Inst Elect & Photon, Fac Elect Engn & Informat Technol, Ilkovicova 3, Bratislava 81219, Slovakia
关键词
Guaifenesin; Screen-printed sensor; Boron-doped diamond electrode; Voltammetry; Flow injection analysis with electrochemical detection; Spectroelectrochemistry; MULTIWALLED CARBON NANOTUBE; MASS-SPECTROMETRY METHOD; GAS-CHROMATOGRAPHY; PARACETAMOL; PHENYLEPHRINE; HYDROCHLORIDE; SULFATE; COUGH; SERUM; CELL;
D O I
10.1016/j.talanta.2024.126809
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton- Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L-1), a wide linear dynamic range (LDR = 0.1-155 mu mol L-1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 mu L) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L-1, LDR = 0.1-50 mu mol L-1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Voltammetric and flow amperometric determination of fungicide cyprodinil in environmental samples using screen-printed sensor with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Borovská, Lucie
    Vagenknecht, Gabriela
    Dušek, Libor
    Behul, Miroslav
    Janíková, Lenka
    Šelešovská, Renáta
    Journal of Environmental Chemical Engineering, 2025, 13 (02):
  • [2] Voltammetric analysis of mephenoxalone drug in pharmaceutical and biological samples using novel screen-printed sensor with boron-doped diamond electrode
    Matvieiev, Oleksandr
    Selesovska, Renata
    Sokolova, Romana
    Jerga, Radek
    Skopalova, Jana
    Bartak, Petr
    Chylkova, Jaromira
    Vojs, Marian
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 397
  • [3] Sensitive Voltammetric Sensor Based on Boron-Doped Diamond Electrode for Determination of the Chemotherapeutic Drug Methotrexate in Pharmaceutical and Biological Samples
    Selesovska, Renata
    Janikova-Bandzuchova, Lenka
    Chylkova, Jaromira
    ELECTROANALYSIS, 2015, 27 (01) : 42 - 51
  • [4] Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode
    Michaela Štěpánková
    Renáta Šelešovská
    Lenka Janíková
    Jaromíra Chýlková
    Chemical Papers, 2017, 71 : 1419 - 1427
  • [5] Voltammetric determination of mesalazine in pharmaceutical preparations and biological samples using boron-doped diamond electrode
    Stepankova, Michaela
    Selesovska, Renata
    Janikova, Lenka
    Chylkova, Jaromira
    CHEMICAL PAPERS, 2017, 71 (08) : 1419 - 1427
  • [6] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Selesovska, Renata
    Krankova, Barbora
    Stepankova, Michaela
    Martinkova, Pavlina
    Janikova, Lenka
    Chylkova, Jaromira
    Navratil, Tomas
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1701 - 1708
  • [7] Sensitive and eco-friendly voltammetric detection of galantamine using a screen-printed sensor with a functional boron-doped diamond electrode
    Dushna, Olha
    Dubenska, Liliya
    Panas, Krystyna
    Gawor, Andrzej
    Marton, Marian
    Vojs, Marian
    Matvieiev, Oleksandr
    Bulska, Ewa
    TALANTA, 2025, 284
  • [8] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Renáta Šelešovská
    Barbora Kränková
    Michaela Štěpánková
    Pavlína Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Tomáš Navrátil
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1701 - 1708
  • [9] Voltammetric Determination of Active Pharmaceutical Ingredients Using Screen-Printed Electrodes
    Clares, Paula
    Perez-Rafols, Clara
    Serrano, Nuria
    Manuel Diaz-Cruz, Jose
    CHEMOSENSORS, 2022, 10 (03)
  • [10] Flow injection simultaneous determination of acetaminophen and tramadol in pharmaceutical and biological samples using multiple pulse amperometric detection with a boron-doped diamond electrode
    Santos, Anderson M.
    Vicentini, Fernando C.
    Figueiredo-Filho, Luiz C. S.
    Deroco, Patricia B.
    Fatibello-Filho, Orlando
    DIAMOND AND RELATED MATERIALS, 2015, 60 : 1 - 8