Single-Slab 3D Fast Spin Echo and Its Variants With Very Long Echo Trains for Clinical T2-Weighted Contrast

被引:0
|
作者
Park, Jaeseok [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Dept Biomed Engn, 2066 Seobu Ro, Suwon 16419, South Korea
[2] Sungkyunkwan Univ, Dept Intelligent Precis Healthcare Convergence, 2066 Seobu Ro, Suwon 16419, South Korea
关键词
Magnetic resonance imaging; Single-slab; 3D; Fast spin echo; Long echo train; Variable flip angle; GRASE; MULTIPLE-SCLEROSIS; GRADIENT-ECHO; INVERSION-RECOVERY; DUAL-ACQUISITION; GRAY-MATTER; FAST FLAIR; FAST MRI; BRAIN; SEQUENCE; DECOMPOSITION;
D O I
10.13104/imri.2023.0033
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single-slab three-dimensional (3D) fast spin echo (FSE) imaging with very long echo trains and its variants are used for producing clinical T2-weighted image contrast. Singleslab 3D FSE imaging with variable refocusing flip angle management strategies permit very long echo trains and, thus, can highly enhance 3D encoding efficiencies. For the flexible control of imaging slabs, both nonselective and selective types of T2-weighted single-slab 3D FSE imaging are described in this review. For clinical applications requiring high lesion sensitivity, the single-slab 3D FSE can be modified to accommodate phasesensitive dual acquisition to enable the attenuation of cerebrospinal fluid (CSF) signals without using conventional long inversion recovery. This approach can be further extended to suppress both CSF and white matter signals for high resolution gray matter-only imaging. Lastly, the single-slab 3D gradient and spin echo (GRASE), which incorporates multiple echoes with phase encoding blips between neighboring refocusing pulses in single-slab 3D FSE imaging, is presented as an effective means for minimizing energy deposition on human tissues and enhancing imaging efficiency. Chemical shift encoding can be applied with single-slab 3D GRASE imaging to efficiently differentiate between fat and water in the presence of magnetic field inhomogeneities.
引用
收藏
页码:167 / 181
页数:15
相关论文
共 50 条
  • [31] Fast Spin-Echo Triple-Echo Dixon: Initial Clinical Experience With A Novel Pulse Sequence for Fat-Suppressed T2-Weighted Abdominal MR Imaging
    Low, Russell N.
    Ma, Jingfei
    Panchal, Neeraj
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 569 - 577
  • [32] CLINICAL UTILITY OF PARTIAL FLIP ANGLE T2-WEIGHTED SPIN-ECHO IMAGING OF THE BRAIN
    CHANG, KH
    YI, JG
    HAN, MH
    CHO, MH
    HAN, MC
    CHO, ZH
    KIM, CW
    NEURORADIOLOGY, 1990, 32 (04) : 255 - 260
  • [33] MRI of acute cerebral infarction: A comparison of FLAIR and T2-weighted fast spin-echo imaging
    Noguchi, K
    Ogawa, T
    Inugami, A
    Fujita, H
    Hatazawa, J
    Shimosegawa, E
    Okudera, T
    Uemura, K
    Seto, H
    NEURORADIOLOGY, 1997, 39 (06) : 406 - 410
  • [34] An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping
    Keerthivasan, Mahesh Bharath
    Saranathan, Manojkumar
    Johnson, Kevin
    Fu, Zhiyang
    Weinkauf, Craig C.
    Martin, Diego R.
    Bilgin, Ali
    Altbach, Maria I.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 326 - 341
  • [35] Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
    Jung, Jee Young
    Yoon, Young Cheol
    Jung, Jin Young
    Choe, Bong-Keun
    ACTA RADIOLOGICA, 2013, 54 (03) : 284 - 291
  • [36] MR Imaging of the Spine at 3.0T with T2-Weighted IDEAL Fast Recovery Fast Spin-Echo Technique
    Ren, Ai-Jun
    Guo, Yong
    Tian, Shu-Ping
    Shi, Li-Jing
    Huang, Min-Hua
    KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) : 44 - 52
  • [37] Differentiation between hepatic cavernous hemangioma and malignant tumor with T2-weighted MRI: Comparison of fast spin-echo and breathhold fast spin-echo pulse sequences
    Soyer, P
    Dufresne, AC
    Somveille, E
    Lenormand, S
    Scherrer, A
    Rymer, R
    CLINICAL IMAGING, 1998, 22 (03) : 200 - 210
  • [38] REDUCTION OF MRT TIMING FOR EXAMINATION OF THE FEMALE PELVIS USING T2-WEIGHTED FAST SPIN-ECHO (FSE) TECHNIQUES - QUANTITATIVE AND QUALITATIVE COMPARISON OF CONVENTIONAL SPIN-ECHO (SE) AND FAST SPIN-ECHO (FSE)
    HALDEMANN, RC
    KRESTIN, GP
    DUEWELL, S
    MARINCEK, B
    VONSCHULTHESS, GK
    SAADIELMANDJRA, M
    FUCHS, WA
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 127 - 132
  • [39] Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI
    de Panafieu, Ariane
    Lecler, Augustin
    Goujon, Adrien
    Krystal, Sidney
    Gueguen, Antoine
    Sadik, Jean-Claude
    Savatovsky, Julien
    Duron, Loic
    INVESTIGATIVE RADIOLOGY, 2023, 58 (05) : 314 - 319
  • [40] Comparing lesion detection of infratentorial multiple sclerosis lesions between T2-weighted spin-echo, 2D-FLAIR, and 3D-FLAIR sequences
    Wang, Kevin Y.
    Uribe, Tomas A.
    Lincoln, Christie M.
    CLINICAL IMAGING, 2018, 51 : 229 - 234