Diagnostic accuracy of two-dimensional shear wave elastography and point shear wave elastography in identifying different stages of liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease: A meta-analysis

被引:0
|
作者
Xu, Xiangyi [1 ]
Zhang, Yiqing [1 ]
Zhu, Qiwei [1 ]
Xie, Yuchen [1 ]
Zhou, Yuanyuan [1 ]
Dong, Bingtian [1 ]
Zhang, Chaoxue [1 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Ultrasound, Hefei, Anhui, Peoples R China
来源
BIOMOLECULES AND BIOMEDICINE | 2025年
关键词
Two-dimensional shear wave elastography; 2-D SWE; point shear wave elastography; pSWE; metabolic dysfunction-associated steatotic liver disease; MASLD; liver fibrosis; GLOBAL EPIDEMIOLOGY; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS; PREVALENCE; OUTCOMES; BIOPSY;
D O I
10.17305/bb.2024.11577
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
To assess the diagnostic accuracy of two-dimensional shear wave elastography (2-D SWE) and point shear wave elastography (pSWE) in detecting liver fibrosis stages in patients with metabolic dysfunction-associated steatotic liver disease (MASLD), a comprehensive search was conducted across four databases up to February 9, 2024. A bivariate random-effects model was used to analyze the diagnostic accuracy of the methods. After screening, 13 studies involving pSWE included 1527 patients, while nine studies involving 2-D SWE included 1088 patients. The areas under the summary receiver operating characteristic (SROC) curves for diagnosing significant fibrosis (F >= 2), advanced fibrosis (F >= 3), and cirrhosis (F = 4) using pSWE and 2-D SWE were as follows: 0.84 (95% CI 0.80-0.87), 0.91 (95% CI 0.88-0.93), and 0.94 (95% CI 0.91-0.95) for pSWE; 0.83 (95% CI 0.79-0.86) 0.85 (95% CI 0.82-0.88), and 0.89 (95% CI 0.86-0.91) for 2-D SWE, respectively. The pooled sensitivity for pSWE and 2-D SWE for stages F >= 2, F >= 3, and F = 4 were 0.71 (95% CI 0.63-0.78), 0.81 (95% CI 0.72-0.88), and 0.81 (95% CI 0.63-0.91) for pSWE, and 0.77 (95% CI 0.68-0.84), 0.80 (95% CI 0.72-0.87), and 0.92 (95% CI 0.75-0.98) for 2-D SWE, respectively. The pooled specificity of pSWE and 2-D SWE for these stages were 0.83 (95% CI 0.76-0.88), 0.87 (95% Cl: 0.81-0.92), and 0.91 (95% CI 0.86-0.94) for pSWE, and 0.76 (95% CI 0.66-0.84), 0.76 (95% CI 0.69-0.82), and 0.83 (95% CI 0.78-0.85) for 2-D SWE, respectively. In conclusion, both 2-D SWE and pSWE demonstrated high diagnostic performance in identifying various stages of liver fibrosis in MASLD patients.
引用
收藏
页数:32
相关论文
共 50 条
  • [41] Diagnostic effect of shear wave elastography imaging for differentiation of malignant liver lesions: a meta-analysis
    Hu, Xing
    Huang, Xiaojie
    Chen, Hui
    Zhang, Tong
    Hou, Jianhua
    Song, Aixin
    Ding, Lei
    Liu, Weiyuan
    Wu, Hao
    Meng, Fankun
    BMC GASTROENTEROLOGY, 2019, 19 (1)
  • [42] Technical Performance of Two-Dimensional Shear Wave Elastography for Measuring Liver Stiffness: A Systematic Review and Meta-Analysis
    Kim, Dong Wook
    Suh, Chong Hyun
    Kim, Kyung Won
    Pyo, Junhee
    Park, Chan
    Jung, Seung Chai
    KOREAN JOURNAL OF RADIOLOGY, 2019, 20 (06) : 880 - 893
  • [43] Shear wave elastography correlates with liver fibrosis scores in pediatric patients with liver disease
    Shannon G. Farmakis
    Paula M. Buchanan
    Miguel A. Guzman
    Anna K. Hardy
    Ajay K. Jain
    Jeffrey H. Teckman
    Pediatric Radiology, 2019, 49 : 1742 - 1753
  • [44] Performance of two-dimensional shear wave elastography for detecting advanced liver fibrosis and cirrhosis in patients with biliary atresia: a systematic review and meta-analysis
    Dong, Bingtian
    Duan, Yayang
    Wang, Huaming
    Chen, Yongjian
    Lyu, Guorong
    PEDIATRIC RADIOLOGY, 2023, 53 (13) : 2642 - 2650
  • [45] Performance of two-dimensional shear wave elastography for detecting advanced liver fibrosis and cirrhosis in patients with biliary atresia: a systematic review and meta-analysis
    Bingtian Dong
    Yayang Duan
    Huaming Wang
    Yongjian Chen
    Guorong Lyu
    Pediatric Radiology, 2023, 53 : 2642 - 2650
  • [46] Comparison of the diagnostic accuracy of shear wave elastography with transient elastography in adult nonalcoholic fatty liver disease: a systematic review and network meta-analysis of diagnostic test accuracy
    Yamaguchi, Ruri
    Oda, Tetsuro
    Nagashima, Kengo
    ABDOMINAL RADIOLOGY, 2025, 50 (02) : 734 - 746
  • [47] Clinical application of two dimensional shear wave elastography with a propagation map in evaluating liver fibrosis in patients with liver tumors
    Wang, Kun
    Han, Hong
    Cao, Jiaying
    Bao, Jingwen
    Wang, Wen-Ping
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2023, 85 (02) : 93 - 104
  • [48] Diagnostic Accuracy Evaluation of Two-Dimensional Shear Wave Elastography in the Differentiation Between Benign and Malignant Thyroid Nodules Systematic Review and Meta-analysis
    Filho, Raimundo Holanda Carneiro
    Pereira, Fernando Linhares
    Iared, Wagner
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (09) : 1729 - 1741
  • [49] The diagnostic performance of shear-wave elastography for liver fibrosis in children and adolescents: A systematic review and diagnostic meta-analysis
    Jeong Rye Kim
    Chong Hyun Suh
    Hee Mang Yoon
    Jin Seong Lee
    Young Ah Cho
    Ah Young Jung
    European Radiology, 2018, 28 : 1175 - 1186
  • [50] Effects of Confounding Factors on Liver Stiffness in Two-Dimensional Shear Wave Elastography in Beagle Dogs
    Cha, Jinwoo
    Kim, Jayon
    Ko, Jaeeun
    Kim, Jaehwan
    Eom, Kidong
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9