Diagnostic accuracy of two-dimensional shear wave elastography and point shear wave elastography in identifying different stages of liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease: A meta-analysis

被引:0
|
作者
Xu, Xiangyi [1 ]
Zhang, Yiqing [1 ]
Zhu, Qiwei [1 ]
Xie, Yuchen [1 ]
Zhou, Yuanyuan [1 ]
Dong, Bingtian [1 ]
Zhang, Chaoxue [1 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Ultrasound, Hefei, Anhui, Peoples R China
来源
BIOMOLECULES AND BIOMEDICINE | 2025年
关键词
Two-dimensional shear wave elastography; 2-D SWE; point shear wave elastography; pSWE; metabolic dysfunction-associated steatotic liver disease; MASLD; liver fibrosis; GLOBAL EPIDEMIOLOGY; WFUMB GUIDELINES; CLINICAL-USE; RECOMMENDATIONS; PREVALENCE; OUTCOMES; BIOPSY;
D O I
10.17305/bb.2024.11577
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
To assess the diagnostic accuracy of two-dimensional shear wave elastography (2-D SWE) and point shear wave elastography (pSWE) in detecting liver fibrosis stages in patients with metabolic dysfunction-associated steatotic liver disease (MASLD), a comprehensive search was conducted across four databases up to February 9, 2024. A bivariate random-effects model was used to analyze the diagnostic accuracy of the methods. After screening, 13 studies involving pSWE included 1527 patients, while nine studies involving 2-D SWE included 1088 patients. The areas under the summary receiver operating characteristic (SROC) curves for diagnosing significant fibrosis (F >= 2), advanced fibrosis (F >= 3), and cirrhosis (F = 4) using pSWE and 2-D SWE were as follows: 0.84 (95% CI 0.80-0.87), 0.91 (95% CI 0.88-0.93), and 0.94 (95% CI 0.91-0.95) for pSWE; 0.83 (95% CI 0.79-0.86) 0.85 (95% CI 0.82-0.88), and 0.89 (95% CI 0.86-0.91) for 2-D SWE, respectively. The pooled sensitivity for pSWE and 2-D SWE for stages F >= 2, F >= 3, and F = 4 were 0.71 (95% CI 0.63-0.78), 0.81 (95% CI 0.72-0.88), and 0.81 (95% CI 0.63-0.91) for pSWE, and 0.77 (95% CI 0.68-0.84), 0.80 (95% CI 0.72-0.87), and 0.92 (95% CI 0.75-0.98) for 2-D SWE, respectively. The pooled specificity of pSWE and 2-D SWE for these stages were 0.83 (95% CI 0.76-0.88), 0.87 (95% Cl: 0.81-0.92), and 0.91 (95% CI 0.86-0.94) for pSWE, and 0.76 (95% CI 0.66-0.84), 0.76 (95% CI 0.69-0.82), and 0.83 (95% CI 0.78-0.85) for 2-D SWE, respectively. In conclusion, both 2-D SWE and pSWE demonstrated high diagnostic performance in identifying various stages of liver fibrosis in MASLD patients.
引用
收藏
页数:32
相关论文
共 50 条
  • [31] Diagnostic value of two dimensional shear wave elastography combined with texture analysis in early liver fibrosis
    Zhao-Cheng Jian
    Jin-Feng Long
    Yu-Jiang Liu
    Xiang-Dong Hu
    Ji-Bin Liu
    Xian-Quan Shi
    Wei-Sheng Li
    Lin-Xue Qian
    World Journal of Clinical Cases, 2019, (10) : 1122 - 1132
  • [32] Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
    Lee, Sang Min
    Kim, Min-Jeong
    Yoon, Jeong Hee
    Hong, Wonju
    Ha, Hong Il
    Lee, Kwanseop
    Choe, Ji-Young
    Lee, Jung Woo
    Yoon, Sam-Youl
    Han, Junhee
    ULTRASONOGRAPHY, 2020, 39 (03) : 288 - 297
  • [33] Performance and cutoffs for liver fibrosis staging of a two-dimensional shear wave elastography technique
    Ferraioli, Giovanna
    Maiocchi, Laura
    Dellafiore, Carolina
    Tinelli, Carmine
    Above, Elisabetta
    Filice, Carlo
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2021, 33 (01) : 89 - 95
  • [34] The diagnostic performance of shear-wave elastography for liver fibrosis in children and adolescents: A systematic review and diagnostic meta-analysis
    Kim, Jeong Rye
    Suh, Chong Hyun
    Yoon, Hee Mang
    Lee, Jin Seong
    Cho, Young Ah
    Jung, Ah Young
    EUROPEAN RADIOLOGY, 2018, 28 (03) : 1175 - 1186
  • [35] Diagnostic performance of two-dimensional shear wave elastography and attenuation imaging for fibrosis and steatosis assessment in chronic liver disease
    Kobayashi, Tamaki
    Nakatsuka, Takuma
    Sato, Masaya
    Soroida, Yoko
    Hikita, Hiromi
    Gotoh, Hiroaki
    Iwai, Tomomi
    Tateishi, Ryosuke
    Kurano, Makoto
    Fujishiro, Mitsuhiro
    JOURNAL OF MEDICAL ULTRASONICS, 2025, 52 (01) : 95 - 103
  • [36] Reliability and applicability of two-dimensional shear-wave elastography for the evaluation of liver stiffness
    Varbobitis, Ioannis C.
    Siakavellas, Spyros I.
    Koutsounas, Ioannis S.
    Karagiannakis, Dimitrios S.
    Ioannidou, Panagiota
    Papageorgiou, Maria-Vasiliki
    Pavlopoulou, Ioanna D.
    Schizas, Dimitrios
    Bamias, Giorgos
    Vlachogiannakos, Ioannis
    Ladas, Spyros D.
    Papatheodoridis, George V.
    EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2016, 28 (10) : 1204 - 1209
  • [37] Assessment of biopsy proven liver fibrosis by two-dimensional shear wave elastography in patients with primary biliary cholangitis
    Yan, Yuling
    Xing, Xian
    Lu, Qiang
    Wang, Xiaoze
    Luo, Xuefeng
    Yang, Li
    DIGESTIVE AND LIVER DISEASE, 2020, 52 (05) : 555 - 560
  • [38] Two-dimensional ultrasound shear wave elastography for identifying and staging liver fibrosis in pediatric patients with known or suspected liver disease: a clinical effectiveness study
    Alhashmi, Ghufran H.
    Gupta, Anita
    Trout, Andrew T.
    Dillman, Jonathan R.
    PEDIATRIC RADIOLOGY, 2020, 50 (09) : 1255 - 1262
  • [39] Two-dimensional ultrasound shear wave elastography for identifying and staging liver fibrosis in pediatric patients with known or suspected liver disease: a clinical effectiveness study
    Ghufran H. Alhashmi
    Anita Gupta
    Andrew T. Trout
    Jonathan R. Dillman
    Pediatric Radiology, 2020, 50 : 1255 - 1262
  • [40] Two-Dimensional Shear Wave Elastography versus Transient Elastography: A Non-Invasive Comparison for the Assessment of Liver Fibrosis in Patients with Chronic Hepatitis C
    Villani, Rosanna
    Cavallone, Francesco
    Romano, Antonino Davide
    Bellanti, Francesco
    Serviddio, Gaetano
    DIAGNOSTICS, 2020, 10 (05)