Comparative treatment planning of very high-energy electrons and photon volumetric modulated arc therapy: Optimising energy and beam parameters

被引:0
|
作者
D'Andrea, Fabio S. [1 ,2 ,3 ]
Chuter, Robert [3 ,4 ]
Aitkenhead, Adam H. [3 ,4 ]
Mackay, Ranald I. [3 ,4 ]
Jones, Roger M. [1 ,2 ]
机构
[1] Univ Manchester, Phys & Astron, Manchester, England
[2] Cockcroft Inst, Accelerator Sci & Technol, Daresbury, England
[3] Christie NHS Fdn Trust, Christie Med Phys & Engn, Manchester, England
[4] Univ Manchester, Div Canc Sci, Manchester, England
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2025年 / 33卷
关键词
VHEE; TPS; Treatment planning; Monte Carlo; Very high-energy electron; Radiotherapy; matRad; VMAT; FLASH; RADIOTHERAPY; VHEE; OPTIMIZATION; VMAT;
D O I
10.1016/j.phro.2025.100732
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Very High-Energy Electron (VHEE) beams offer potential advantages over current clinical radiotherapy modalities due to their precise dose targeting and minimal peripheral dose spread, which is ideal for treating deep-seated tumours. To aid the development of clinical VHEE machines, this study adressed the need to identify optimum VHEE beam characteristics for tumours across various anatomical sites.<br /> Materials and methods: VHEE treatment planning employed matRad, an open-source treatment planning system, by adapting its proton pencil beam scanning implementation. VHEE beam characteristics were generated using TOPAS Monte Carlo simulations. A total of 820 plans were retrospectively created and analysed across 10 pelvic and 12 thoracic cases and compared against clinical photon VMAT plans to identify the most optimal VHEE beam configuration and energy requirement.<br /> Results: VHEE plans outperformed photon VMAT in sparing organs-at-risk (OARs) while maintaining or improving target coverage. While 150 MeV served as the threshold for effectively treating deep-seated sites, 200 MeV was identified as a more optimal energy in the pelvis for achieving the best balance of penetration and sparing abutting OARs. Lower energies (70-110 MeV) also benefitted mid-to-superficial disease in the lung cohort. Typically, VHEE plans required 3-5 fields, and resulted in notable dose reductions to OARs across treatment sites, including: 22.5% reduction in rectal Dmean; 13.8% decrease in bladder Dmean; 8.2% reduction in heart Dmean; and a 24.4% decrease in lung V20Gy.<br /> Conclusion: The study reinforces VHEE's potential in clinical settings, emphasising the need for varied energy ranges to enhance treatment flexibility and effectiveness.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Considerations in Bilateral Lung Treatment Planning With Volumetric Modulated Arc Therapy
    Song, Y.
    Mueller, B. A.
    Laguna, J.
    Obcemea, C. H.
    Saleh, Z.
    Tang, X.
    Both, S.
    Mychalczak, B. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E684 - E684
  • [32] A fast optimization approach for treatment planning of volumetric modulated arc therapy
    Yan, Hui
    Dai, Jian-Rong
    Li, Ye-Xiong
    RADIATION ONCOLOGY, 2018, 13
  • [33] A fast optimization approach for treatment planning of volumetric modulated arc therapy
    Hui Yan
    Jian-Rong Dai
    Ye-Xiong Li
    Radiation Oncology, 13
  • [34] CHARACTERISTICS OF CONTAMINATION ELECTRONS IN HIGH-ENERGY PHOTON BEAMS
    BEAUVAIS, H
    BRIDIER, A
    DUTREIX, A
    RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) : 308 - 316
  • [35] Treatment-Planning Study for Very High-Energy Electron Beam Radiation Therapy: Integral Dose Reduction for Pediatric Patients
    Bazalova, M.
    Qu, B.
    Palma, B.
    Hynning, E.
    Hardemark, B.
    Maxim, P. G.
    Loo, B. W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S935 - S936
  • [36] Treatment planning consideration for very high-energy electron FLASH radiotherapy
    Zhang, Guoliang
    Zhang, Zhengzhao
    Gao, Wenchao
    Quan, Hong
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 107
  • [37] Radiosurgery treatment planning using conformal arc informed volumetric modulated arc therapy
    Giles, William M.
    Cullom, Edward T.
    Laryea, Obed A. -O.
    Nobah, Ahmad
    Alves, Victor G. L.
    Yin, Fang-Fang
    Kirkpatrick, John P.
    Adamson, Justus D.
    MEDICAL DOSIMETRY, 2021, 46 (01) : 3 - 12
  • [38] CALCULATION OF THE DOSE IN THE BUILDUP REGION FOR HIGH-ENERGY PHOTON-BEAM - TREATMENT PLANNING WHEN BEAM SPOILERS ARE EMPLOYED
    MCKENNA, MG
    CHEN, XG
    ALTSCHULER, MD
    BLOCH, P
    RADIOTHERAPY AND ONCOLOGY, 1995, 34 (01) : 63 - 68
  • [39] Very High Energy Electrons (VHEE): Treatment planning comparison and machine design
    D'Andrea, Fabio S.
    Jones, Roger M.
    MacKay, Ranald
    Chuter, Robert
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3593 - S3596
  • [40] Treatment planning for very high energy electrons: Studies that indicate the potential of the modality
    Bedford, James L.
    Oelfke, Uwe
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32