Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema

被引:0
|
作者
Shemer, Asaf [1 ,2 ]
Fradkin, Maayan [1 ,2 ]
Dubinsky-Pertzov, Biana [1 ,2 ]
Reitblat, Olga [2 ,3 ]
Simaan, Francis [1 ,2 ]
Sella, Ruti [2 ,3 ]
Pras, Eran [1 ,2 ,4 ]
Einan-Lifshitz, Adi [1 ,2 ]
机构
[1] Shamir Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
[2] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[3] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[4] Shamir Med Ctr, Dept Ophthalmol, Matlows Ophthalmo Genet Lab, Zerifin, Israel
来源
关键词
REFRACTIVE OUTCOMES; CATARACT-SURGERY; KERATOPLASTY;
D O I
10.1097/j.jcrs.0000000000001578
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of several intraocular lens (IOL) formulas for patients with endothelial dystrophy (ED) without edema treated with cataract surgery alone. Setting: 1 academic, tertiary referral center. Design: Comparative retrospective cohort study. Methods: The predicted refractive results of patients with ED who underwent cataract surgery were assessed and compared with a matched control group. The accuracy of 5 different IOL formulas, Haigis, Holladay 1, Barrett Universal II (BUII), SRK/T, and Kane, was evaluated and compared between the groups. The SDs of the prediction error (PE) of all formulas were compared. Results:221 eyes were included in this study. 50 (23%) eyes of patients with ED and 171 (77%) control eyes. There was no significant difference between the 2 groups in clinical and demographical characteristics (P > .05). The postoperative spherical equivalent was -0.37 diopters (D) in the ED group and -0.30 D in the control group (P = .8). Overall, both groups had a comparable SD of the PE and absolute PE in all formulas (P > .05). In the ED group, absolute PE was 0.34 D for Haigis, 0.32 D for Holladay 1, 0.32 D for BUII, 0.38 D for SRK/T, and 0.32 D for Kane formulas. No statistically significant difference between formulas was found. Conclusions: The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [41] Accuracy of biometry using automated and manual keratometry for intraocular lens power calculation
    Khan, Lubna
    Sharma, Babita
    Gupta, Harshal
    Rana, Rimpi
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2018, 8 (02) : 93 - 98
  • [42] Accuracy of a universal theoretical formula for power calculation in pediatric intraocular lens implantation
    Eppley, Sarah E.
    Arnold, Benjamin F.
    Tadros, Dina
    Pasricha, Neel
    Campomanes, Alejandra G. de Alba
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 599 - 605
  • [43] Accuracy of a new intraocular lens power calculation method based on artificial intelligence
    David Carmona González
    Carlos Palomino Bautista
    Eye, 2021, 35 : 517 - 522
  • [44] Accuracy of 14 intraocular lens power calculation formulas in extremely long eyes
    Li, Xinxin
    Song, Chunyuan
    Wang, Yong
    Wang, Jing
    Tang, Qiongyan
    Wu, Zheming
    Zhou, Yanwen
    Sun, Juan
    Jia, Yanhong
    Lin, Zhenlin
    Li, Shaowei
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (11) : 3619 - 3628
  • [45] Accuracy of a new intraocular lens power calculation method based on artificial intelligence
    Carmona Gonzalez, David
    Palomino Bautista, Carlos
    EYE, 2021, 35 (02) : 517 - 522
  • [46] Accuracy and predictability of intraocular lens power calculation after laser in situ keratomileusis
    Gimbel, HV
    Sun, R
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 571 - 576
  • [47] Comparative accuracy of intraocular lens power calculation formulas when targeting myopia
    Yang, Soonwon
    Park, Chanjoon
    Byun, Yong-Soo
    Chung, So-Hyang
    Kim, Hyun Seung
    HELIYON, 2024, 10 (13)
  • [48] FACTORS INFLUENCING THE ACCURACY OF THE SRK FORMULA IN THE INTRAOCULAR-LENS POWER CALCULATION
    KALOGEROPOULOS, C
    ASPIOTIS, M
    STEFANIOTOU, M
    PSILAS, K
    DOCUMENTA OPHTHALMOLOGICA, 1994, 85 (03) : 223 - 242
  • [49] Accuracy of Formulas for Intraocular Lens Power Calculation After Myopic Refractive Surgery
    Lanza, Michele
    Ruggiero, Adriano
    Ha, Jason
    Simonelli, Francesca
    Kane, Jack X.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (07) : 443 - 449
  • [50] Accuracy of Intraocular Lens Calculation Formulas in Patients Undergoing Combined Phakic Intraocular Lens Removal and Cataract Surgery
    Zhang, Jiaqing
    Xia, Zhaoxia
    Han, Xiaotong
    Liu, Zhenzhen
    Lin, Haowen
    Qiu, Xiaozhang
    Zhang, Miao
    Ruan, Xiaoting
    Chen, Xiaoyun
    Jin, Guangming
    Gu, Xiaoxun
    Tan, Xuhua
    Luo, Lixia
    Liu, Yizhi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 234 : 241 - 249