Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema

被引:0
|
作者
Shemer, Asaf [1 ,2 ]
Fradkin, Maayan [1 ,2 ]
Dubinsky-Pertzov, Biana [1 ,2 ]
Reitblat, Olga [2 ,3 ]
Simaan, Francis [1 ,2 ]
Sella, Ruti [2 ,3 ]
Pras, Eran [1 ,2 ,4 ]
Einan-Lifshitz, Adi [1 ,2 ]
机构
[1] Shamir Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
[2] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[3] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[4] Shamir Med Ctr, Dept Ophthalmol, Matlows Ophthalmo Genet Lab, Zerifin, Israel
来源
关键词
REFRACTIVE OUTCOMES; CATARACT-SURGERY; KERATOPLASTY;
D O I
10.1097/j.jcrs.0000000000001578
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of several intraocular lens (IOL) formulas for patients with endothelial dystrophy (ED) without edema treated with cataract surgery alone. Setting: 1 academic, tertiary referral center. Design: Comparative retrospective cohort study. Methods: The predicted refractive results of patients with ED who underwent cataract surgery were assessed and compared with a matched control group. The accuracy of 5 different IOL formulas, Haigis, Holladay 1, Barrett Universal II (BUII), SRK/T, and Kane, was evaluated and compared between the groups. The SDs of the prediction error (PE) of all formulas were compared. Results:221 eyes were included in this study. 50 (23%) eyes of patients with ED and 171 (77%) control eyes. There was no significant difference between the 2 groups in clinical and demographical characteristics (P > .05). The postoperative spherical equivalent was -0.37 diopters (D) in the ED group and -0.30 D in the control group (P = .8). Overall, both groups had a comparable SD of the PE and absolute PE in all formulas (P > .05). In the ED group, absolute PE was 0.34 D for Haigis, 0.32 D for Holladay 1, 0.32 D for BUII, 0.38 D for SRK/T, and 0.32 D for Kane formulas. No statistically significant difference between formulas was found. Conclusions: The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [21] Intraocular lens power calculation formula accuracy: Comparison of 12 formulas for a trifocal hydrophilic intraocular lens
    Rocha-de-Lossada, Carlos
    Colmenero-Reina, Elvira
    Flikier, David
    Castro-Alonso, Francisco-Javier
    Rodriguez-Raton, Alvaro
    Garcia-Madrona, Jose-Luis
    Peraza-Nieves, Jorge
    Sanchez-Gonzalez, Jose-Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 2981 - 2988
  • [22] Accuracy of Intraocular Lens Calculation Formulas
    Melles, Ronald B.
    Holladay, Jack T.
    Chang, William J.
    OPHTHALMOLOGY, 2018, 125 (02) : 169 - 178
  • [23] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [24] Accuracy of Intraocular Lens Power Calculation in Eyes Filled with Silicone Oil
    Kanclerz, Piotr
    Grzybowski, Andrzej
    SEMINARS IN OPHTHALMOLOGY, 2019, 34 (05) : 392 - 397
  • [25] Accuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [26] Accuracy of Intraocular Lens Power Calculation Formulas in Patients With Multifocal Intraocular Lens Implantation With Optic Capture in Berger Space for Pediatric Cataract
    Wang, Menghan
    Li, Dongfang
    Fan, Zheng
    Zhang, Jing
    Zhou, Jinyan
    Huang, Yusen
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2023, 60 (02) : 139 - +
  • [27] Accuracy of biometric formulae for intraocular lens power calculation in a teaching hospital
    Tang, Kevin S.
    Tran, Elaine M.
    Chen, Allison J.
    Rivera, David R.
    Rivera, Jorge J.
    Greenberg, Paul B.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (01) : 61 - 65
  • [28] Accuracy of intraocular lens power calculation formulas for highly myopic eyes
    Zhang, Yichi
    Liang, Xiao Ying
    Liu, Shu
    Lee, Jacky W. Y.
    Bhaskar, Srinivasan
    Lam, Dennis S. C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [29] Accuracy of biometric formulae for intraocular lens power calculation in a teaching hospital
    Kevin S Tang
    Elaine M Tran
    Allison J Chen
    David R Rivera
    Jorge J Rivera
    Paul B Greenberg
    International Journal of Ophthalmology, 2020, 13 (01) : 61 - 65
  • [30] Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy
    Gimbel, HV
    Sun, R
    Furlong, MT
    van Westenbrugge, JA
    Kassab, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08): : 1147 - 1151