Accuracy of intraocular lens power calculation in patients with endothelial dystrophy without edema

被引:0
|
作者
Shemer, Asaf [1 ,2 ]
Fradkin, Maayan [1 ,2 ]
Dubinsky-Pertzov, Biana [1 ,2 ]
Reitblat, Olga [2 ,3 ]
Simaan, Francis [1 ,2 ]
Sella, Ruti [2 ,3 ]
Pras, Eran [1 ,2 ,4 ]
Einan-Lifshitz, Adi [1 ,2 ]
机构
[1] Shamir Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
[2] Tel Aviv Univ, Fac Med, Tel Aviv, Israel
[3] Rabin Med Ctr, Dept Ophthalmol, Petah Tiqwa, Israel
[4] Shamir Med Ctr, Dept Ophthalmol, Matlows Ophthalmo Genet Lab, Zerifin, Israel
来源
关键词
REFRACTIVE OUTCOMES; CATARACT-SURGERY; KERATOPLASTY;
D O I
10.1097/j.jcrs.0000000000001578
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the accuracy of several intraocular lens (IOL) formulas for patients with endothelial dystrophy (ED) without edema treated with cataract surgery alone. Setting: 1 academic, tertiary referral center. Design: Comparative retrospective cohort study. Methods: The predicted refractive results of patients with ED who underwent cataract surgery were assessed and compared with a matched control group. The accuracy of 5 different IOL formulas, Haigis, Holladay 1, Barrett Universal II (BUII), SRK/T, and Kane, was evaluated and compared between the groups. The SDs of the prediction error (PE) of all formulas were compared. Results:221 eyes were included in this study. 50 (23%) eyes of patients with ED and 171 (77%) control eyes. There was no significant difference between the 2 groups in clinical and demographical characteristics (P > .05). The postoperative spherical equivalent was -0.37 diopters (D) in the ED group and -0.30 D in the control group (P = .8). Overall, both groups had a comparable SD of the PE and absolute PE in all formulas (P > .05). In the ED group, absolute PE was 0.34 D for Haigis, 0.32 D for Holladay 1, 0.32 D for BUII, 0.38 D for SRK/T, and 0.32 D for Kane formulas. No statistically significant difference between formulas was found. Conclusions: The prediction accuracy of IOL power calculation in patients with ED was found comparable both between formulas and in comparison with healthy controls. This suggests that in patients with guttate without edema, the IOL power calculations are as effective and accurate as in healthy eyes.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [1] Accuracy of lens power calculation and centration of an aspheric intraocular lens
    Becker, K. A.
    Holzer, M. P.
    Reuland, A. J.
    Auffarth, G. U.
    OPHTHALMOLOGE, 2006, 103 (10): : 873 - 876
  • [2] Accuracy of intraocular lens power calculation in eyes with keratoconus
    Kojima, Takashi
    Horai, Rie
    Isogai, Naoki
    Nakamura, Tomoaki
    Tamaoki, Akeno
    Ichikawa, Kazuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [3] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Zhao, Jing
    Liu, Liang-Ping
    Cheng, Huan-Huan
    Li, Jian-Bing
    Han, Xiao-Tong
    Liu, Yu
    Wu, Ming-Xing
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1378 - 1384
  • [4] Intraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy
    Alnawaiseh, Maged
    Zumhagen, Lars
    Rosentreter, Andre
    Eter, Nicole
    BMC OPHTHALMOLOGY, 2017, 17
  • [5] Accuracy of eight intraocular lens power calculation formulas for segmented multifocal intraocular lens
    Jing Zhao
    Liang-Ping Liu
    Huan-Huan Cheng
    Jian-Bing Li
    Xiao-Tong Han
    Yu Liu
    Ming-Xing Wu
    International Journal of Ophthalmology, 2020, (09) : 1378 - 1384
  • [6] Intraocular lens power calculation using standard formulas and ray tracing after DMEK in patients with Fuchs endothelial dystrophy
    Maged Alnawaiseh
    Lars Zumhagen
    André Rosentreter
    Nicole Eter
    BMC Ophthalmology, 17
  • [7] Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients
    Pingjun Chang
    Lei Lin
    Zhangliang Li
    Li Wang
    Jinhai Huang
    Yun-e Zhao
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1123 - 1131
  • [8] Accuracy of 8 intraocular lens power calculation formulas in pediatric cataract patients
    Chang, Pingjun
    Lin, Lei
    Li, Zhangliang
    Wang, Li
    Huang, Jinhai
    Zhao, Yun-e
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (05) : 1123 - 1131
  • [9] Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
    Savini, Giacomo
    Barboni, Piero
    Carbonelli, Michele
    Hoffer, Kenneth J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (07): : 1193 - 1197
  • [10] Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation
    Jingyi Shi
    Zehui Zhu
    Bin Hu
    Shuyi Qian
    Yalan Wang
    Pingjun Chang
    Yun-e Zhao
    Ophthalmology and Therapy, 2024, 13 : 1321 - 1342