A comparison of McGrath video laryngoscope and Macintosh laryngoscope during nasotracheal intubation: A randomised controlled study

被引:0
作者
Gangishetty, Alekhya [1 ]
Jonnavithula, Nirmala [1 ]
Geetha, Singam [1 ]
Muthyala, Harshini [1 ]
Peetha, Hareesh [1 ]
机构
[1] Nizams Inst Med Sci, Dept Anaesthesia & Crit Care, Hyderabad 500082, India
关键词
MacIntosh; Faciomaxillary; McGrath; Intubation; Laryngoscope; Airway; CONTROLLED-TRIAL; DIFFICULT; VIDEOLARYNGOSCOPE; MANAGEMENT;
D O I
10.1177/17504589241270202
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Nasotracheal intubation is challenging for anaesthesiologists in faciomaxillary injuries due to the anticipated difficult airways. The effectiveness of a non-channelled McGrath video laryngoscope was compared with a conventional Macintosh laryngoscope during nasotracheal intubation.Methods: Sixty American Society of Anaesthesiologists I-II patients aged between 18 and 60 years of both sexes undergoing elective faciomaxillary surgeries from September 2019 to February 2020 were prospectively randomised into two groups (Macintosh laryngoscope Group, McGrath video laryngoscope Group) of 30. The primary outcome was ease of intubation (Modified Intubation Difficulty Scale) and Nasotracheal intubation time (T1 time: from nostril to nasopharynx, T2 time: from nasopharynx until the first ETCO2, total time: T1 + T2). The secondary outcomes were Cormac Lehane grade, additional manoeuvres requirement, intubation failure, tracheostomy incidence and associated complications.Results: T1, T2 and total (T1 + T2) time (mean +/- SD) were statistically prolonged in the McGrath video laryngoscope than Macintosh laryngoscope group, with p = 0.044, p = 0.000 and p = 0.000, respectively. The McGrath video laryngoscope facilitated a better laryngoscopic view (p = 0.002), favourable intubation difficulty scale scores, less lifting force (p = 0.002), reduced lip trauma (p = 0.002) and decreased Magill's forceps use (p = 0.002) than the Macintosh laryngoscope group.Conclusion: Despite longer intubation time, the non-channelled McGrath video laryngoscope offered favourable intubating conditions with superior glottis view, less lifting force and reduced Magill's forceps requirement, causing decreased airway trauma, lower intubation difficulty scale scores than Macintosh laryngoscope for nasotracheal intubation.
引用
收藏
页码:378 / 383
页数:6
相关论文
共 50 条
[21]   Comparison of the time to successful endotracheal intubation using the Macintosh laryngoscope or KingVision video laryngoscope in the emergency department: A prospective observational study [J].
Mallick, Tanvi ;
Verma, Ankur ;
Jaiswal, Sanjay ;
Haldar, Meghna ;
Sheikh, Wasil Rasool ;
Vishen, Amit ;
Snehy, Abhishek ;
Ahuja, Rinkey .
TURKISH JOURNAL OF EMERGENCY MEDICINE, 2020, 20 (01) :22-27
[22]   Randomized comparison of McGrath MAC videolaryngoscope, Pentax Airway Scope, and Macintosh direct laryngoscope for nasotracheal intubation in patients with manual in-line stabilization [J].
Roh, Go Un ;
Kwak, Hyun Jeong ;
Lee, Kyung Cheon ;
Lee, Sun Young ;
Kim, Jong Yeop .
CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (10) :1213-1220
[23]   Intubation with King Vision® video laryngoscope and Macintosh laryngoscope in cervical spine injured: A randomized controlled trial [J].
Kumar, Mohit ;
Gupta, Abhinav ;
Mahajan, Harikishan ;
Dhanerwa, Ravinder ;
Chauhan, Parashuram .
INDIAN ANAESTHETISTS FORUM, 2019, 20 (02) :89-94
[24]   COMPARISON OF THE KING VISION VIDEO LARYNGOSCOPE WITH THE MACINTOSH LARYNGOSCOPE [J].
Murphy, Laurel D. ;
Kovacs, George J. ;
Reardon, Peter M. ;
Law, John Adam .
JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (02) :239-245
[25]   Comparison of Airtraq with Macintosh Laryngoscope for Endotracheal Intubation in Paediatric Patients: A Randomised Controlled Trial [J].
Dwivedi, Yogita ;
Jain, Ankit ;
Yadav, Vijay Pratap ;
Agarwal, Atiharsh Mohan .
JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (03) :UC16-UC18
[26]   The Accuracy of Tests Used to Predict Difficult Airway and a Comparison of Macintosh Laryngoscope to Video Laryngoscope for Intubation [J].
Mingir, Tarkan ;
Kitapcioglu, Dilek ;
Turgut, Namigar ;
Yumru, Cengiz .
KUWAIT MEDICAL JOURNAL, 2015, 47 (03) :201-209
[27]   McGRATH MAC video laryngoscope for insertion of a transoesophageal echocardiography probe A randomised controlled trial [J].
Ishida, Takashi ;
Kiuchi, Chiaki ;
Sekiguchi, Takemi ;
Tsujimoto, Takatoshi ;
Kawamata, Mikito .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (04) :263-268
[28]   Comparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics [J].
Piepho, Tim ;
Weinert, Kathrin ;
Heid, Florian M. ;
Werner, Christian ;
Noppens, Ruediger R. .
SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2011, 19 :4
[29]   IS AIRTRAQ VIDEO LARYNGOSCOPE A BETTER ALTERNATIVE TO CONVENTIONAL MACINTOSH DIRECT LARYNGOSCOPE DURING ROUTINE INTUBATION? A COMPARATIVE STUDY [J].
Mahmood, Syed Fazal ;
Padmanabha, S. .
JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (93) :15903-15904
[30]   Comparison of two different shapes of stylets for intubation with the McGrath MAC® video laryngoscope: a randomized controlled trial [J].
Lim, Hyunyoung ;
Cha, Yun-Byeong ;
Ryu, Kyoung-Ho ;
Lee, Sung Hyun ;
Cho, Eun-Ah .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (10)