Cure Efficiency and Biocompatibility of an Iron-Based Coordination Complex as a Photoinitiator for Dental 3D-Printed Resins

被引:0
|
作者
Singh, Sharanya [1 ]
Rocha, Mateus Garcia [1 ]
Sinhoreti, Mario Alexandre Coelho [2 ]
Silvino, Alexandre Carneiro [3 ]
Oliveira, Dayane [1 ]
机构
[1] Univ Florida, Coll Dent, Ctr Dent Biomat, Dept Restorat Dent Sci, 1390 Ctr Dr, Gainesville, FL 32610 USA
[2] State Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Restorat Dent, Dent Mat Div, 901 Limeira Ave, BR-13414903 Piracicaba, SP, Brazil
[3] Univ Fed Rio de Janeiro, Prof Eloisa Mano Macromol Inst, 2030 Horacio Macedo Ave,Cidade Univ, BR-21941598 Rio De Janeiro, RJ, Brazil
来源
JOURNAL OF COMPOSITES SCIENCE | 2025年 / 9卷 / 01期
关键词
cytotoxicity; degree of conversion; dental photoinitiator;
D O I
10.3390/jcs9010026
中图分类号
TB33 [复合材料];
学科分类号
摘要
Objective: The aim of this study was to evaluate the cure efficiency and biocompatibility of a novel iron-based coordination complex used as a photoinitiator in comparison to conventional ethyl (2,4,6-trimethylbenzoyl) phenylphosphinate (TPO-L) and camphorquinone (CQ) as photoinitiators in dental 3D-printed resins. Materials and Methods: Experimental dental resin formulations were prepared by blending 1:1 ratio of Bis-GMA and TEGDMA, to which 0.2 wt% of either the iron-based coordination complex or CQ were added, along with 0.2 wt% EDAB and 0.4 wt% IOD, and the TPO-L. The degree of conversion (DC) was measured using Fourier transform infrared spectroscopy (FTIR). Biocompatibility was assessed by evaluating the viability of L929 fibroblast-like cells using the MTT assay 24 h post-exposure. Statistical analyses included a two-way ANOVA followed by Tukey's test for post hoc comparisons, with significance at p < 0.05. Results: The degree of conversion for the iron-based coordination complex (84.54% +/- 1.69%) was significantly higher than that for the TPO-L (78.77% +/- 1.25%) and CQ-based resins (73.21% +/- 0.47%) (p < 0.001). The iron-based coordination complex and TPO-L resins exhibited significantly higher conversion than CQ-based resins (p < 0.001). Regarding biocompatibility, the cell viability test revealed that the iron-based coordination complex demonstrated the highest cell viability at 86.5% +/- 10.24%, followed by TPO-L with 80.03% +/- 11.07%. CQ showed the lowest cell viability of 51.29% +/- 8.44% (p < 0.05). Tukey's test confirmed significant differences between CQ and other photointiators (p < 0.05), while no significant difference was found between TPO-L and the iron-based coordination complex. Conclusions: This study introduces a novel iron-based coordination complex photoinitiator that demonstrates enhanced cure efficiency and comparable biocompatibility to TPO-L, while significantly reducing the cytotoxicity associated with CQ. Its longer absorption wavelength supports deeper layer curing, making it a promising alternative for dental 3D printing, particularly in bioactive scaffold applications requiring minimized cytotoxicity.
引用
收藏
页数:10
相关论文
共 4 条
  • [1] Biocompatibility of 3D-Printed Dental Resins: A Systematic Review
    Prakash, Jayant
    Shenoy, Mahesh
    Alhasmi, Abdulmajeed
    Saleh, Azzam A. Al
    Shivakumar, G. C.
    Shivakumar, Sahana
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [2] 3D-printed resins for provisional dental restorations: Comparison of mechanical and biological properties
    Atria, Pablo J.
    Bordin, Dimorvan
    Marti, Felipe
    Nayak, Vasudev Vivekanand
    Conejo, Julian
    Jalkh, Ernesto Benalcazar
    Witek, Lukasz
    Sampaio, Camila S.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2022, 34 (05) : 804 - 815
  • [3] Mechanical and Biocompatibility Properties of 3D-Printed Dental Resin Reinforced with Glass Silica and Zirconia Nanoparticles: In Vitro Study
    Alshamrani, Abdullah
    Alhotan, Abdulaziz
    Kelly, Elizabeth
    Ellakwa, Ayman
    POLYMERS, 2023, 15 (11)
  • [4] Degree of conversion and residual monomer elution of 3D-printed, milled and self-cured resin-based composite materials for temporary dental crowns and bridges
    Berghaus, Eva
    Klocke, Thorsten
    Maletz, Reinhard
    Petersen, Svea
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2023, 34 (05)