Retrospective analysis of treatment-positioning accuracy and dose error in boron neutron capture therapy using a sitting-position treatment system for head and neck cancer

被引:0
作者
Komori, Shinya [1 ]
Hirose, Katsumi [2 ]
Sato, Mariko [2 ]
Yamazaki, Yuhei [1 ]
Takeuchi, Akihiko [1 ]
Kato, Ryohei [1 ]
Motoyanagi, Tomoaki [1 ]
Narita, Yuki [1 ]
Kato, Takahiro [3 ]
Takai, Yoshihiro [4 ]
机构
[1] Southern Tohoku BNCT Res Ctr, Dept Radiat Phys & Technol, 7-10 Yatsuyamada, Koriyama, Fukushima 9638052, Japan
[2] Hirosaki Univ, Dept Radiat Oncol, Grad Sch Med, 5 Zaifu Cho, Hirosaki, Aomori 0368562, Japan
[3] Fukushima Med Univ, Sch Hlth Sci, 10-6 Sakaemachi, Fukushima, Fukushima 9608516, Japan
[4] Southern Tohoku BNCT Res Ctr, Dept Radiat Oncol, 7-10 Yatsuyamada, Koriyama, Fukushima 9638052, Japan
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2024年 / 126卷
关键词
Boron neutron capture therapy; Sitting position; Dose error; Head and neck cancer; RELATIVE BIOLOGICAL EFFECTIVENESS; SETUP ERRORS; PATIENT SETUP; RADIOTHERAPY; IRRADIATION; RECURRENT; VOLUME; IMRT; BNCT;
D O I
10.1016/j.ejmp.2024.104818
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The neutron beam in boron neutron capture therapy (BNCT) exhibits poor directionality and significantly decreasing neutron flux with increasing distance. Therefore, the treatment site must be close to the irradiation aperture. Some patients with head and neck cancer may benefit from a sitting-position setup. The study aim was to evaluate the treatment-positioning accuracy and dose error in sitting patients receiving BNCT. Thirty-two patients with head and neck cancer who underwent sitting-position BNCT at Southern Tohoku BNCT Research Center were included in the study. Horizontal (Delta X) and vertical (Delta Y) errors were defined as the displacement between the treatment planning system (TPS) digital reconstructed radiograph and the pre-treatment X-ray image. Using in-house software, image matching was performed. The beam-axial directional (Delta Z) error was compared with the parameters entered into the TPS and the actual pre-treatment measured values. The translational-position error was reflected in the TPS's patient coordinate system with respect to the reference plan. Re-dose calculations were performed to evaluate the effect of positional error on tumor and normal-tissue doses. The [Delta X, Delta Y, Delta Z] (DRR-CR) mean +/- 1SD were - 0.40 +/- 2.0, 0.30 +/- 2.3, and - 1.4 +/- 1.5 mm, respectively. The D-mean and D-98% tumor-dose errors were 1.22 % +/- 1.44 % and 0.99 % +/- 1.63 %, respectively. The D-2% pharyngeal and oral mucosal-dose errors were 0.98 % +/- 1.91 % and 1.21 % +/- 1.78 %, respectively. The tumor- and normal-tissue dose errors were typically < 5 %. High-precision treatment was feasible in sitting-positioned BNCT.
引用
收藏
页数:12
相关论文
共 46 条
  • [21] Effectiveness of BNCT for recurrent head and neck malignancies
    Kato, I
    Ono, K
    Sakurai, Y
    Ohmae, M
    Maruhashi, A
    Imahori, Y
    Kirihata, M
    Nakazawa, M
    Yura, Y
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (05) : 1069 - 1073
  • [22] Dosimetric effects of the ipsilateral shoulder position variations in the sitting-positioned boron neutron capture therapy for lower neck tumor
    Kato, Ryohei
    Hirose, Katsumi
    Kato, Takahiro
    Motoyanagi, Tomoaki
    Arai, Kazuhiro
    Harada, Takaomi
    Takeuchi, Akihiko
    Yamazaki, Yuhei
    Narita, Yuki
    Komori, Shinya
    Sato, Mariko
    Takai, Yoshihiro
    [J]. APPLIED RADIATION AND ISOTOPES, 2022, 188
  • [23] Design and construction of an accelerator-based boron neutron capture therapy (AB-BNCT) facility with multiple treatment rooms at the Southern Tohoku BNCT Research Center
    Kato, Takahiro
    Hirose, Katsumi
    Tanaka, Hiroki
    Mitsumoto, Toshinori
    Motoyanagi, Tomoaki
    Arai, Kazuhiro
    Harada, Takaomi
    Takeuchi, Akihiko
    Kato, Ryohei
    Yajima, Satoru
    Takai, Yoshihiro
    [J]. APPLIED RADIATION AND ISOTOPES, 2020, 156
  • [24] Dosimetric effect of set-up error in accelerator-based boron neutron capture therapy for head and neck cancer
    Komori, Shinya
    Hirose, Katsumi
    Sato, Mariko
    Takeuchi, Akihiko
    Kato, Ryohei
    Motoyanagi, Tomoaki
    Harada, Takaomi
    Yamazaki, Yuhei
    Harada, Mayumi
    Narita, Yuki
    Kato, Takahiro
    Takai, Yoshihiro
    [J]. JOURNAL OF RADIATION RESEARCH, 2022, 63 (04) : 684 - 695
  • [25] Posture-induced changes in the vessels of the head and neck: evaluation using conventional supine CT and upright CT
    Kosugi, Kenzo
    Yamada, Yoshitake
    Yamada, Minoru
    Yokoyama, Yoichi
    Fujiwara, Hirokazu
    Yoshida, Keisuke
    Yoshida, Kazunari
    Toda, Masahiro
    Jinzaki, Masahiro
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [26] Project for the development of the linac based NCT facility in University of Tsukuba
    Kumada, H.
    Matsumura, A.
    Sakurai, H.
    Sakae, T.
    Yoshioka, M.
    Kobayashi, H.
    Matsumoto, H.
    Kiyanagi, Y.
    Shibata, T.
    Nakashima, H.
    [J]. APPLIED RADIATION AND ISOTOPES, 2014, 88 : 211 - 215
  • [27] Leo Cancer Care, 2023, Leo Cancer Care website
  • [28] Locher GL, 1936, AM J ROENTGENOL RADI, V36, P1
  • [29] MANTLE IRRADIATION IN THE UPRIGHT POSITION - A TECHNIQUE TO REDUCE THE VOLUME OF LUNG IRRADIATED IN PATIENTS WITH BULKY MEDIASTINAL HODGKINS-DISEASE
    MARCUS, KC
    SVENSSON, G
    RHODES, LP
    MAUCH, PM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (02): : 443 - 447
  • [30] Reproducibility of patient setup in the seated treatment position: A novel treatment chair design
    McCarroll, Rachel E.
    Beadle, Beth M.
    Fullen, Danna
    Balter, Peter A.
    Followill, David S.
    Stingo, Francesco C.
    Yang, Jinzhong
    Court, Laurence E.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 223 - 229