Diagnostic accuracy of strain cervical elastography as a predictor for preterm delivery: A single tertiary care centre study

被引:0
|
作者
Sharma, Abhinash [1 ]
Thakur, Shruti [1 ]
Tomar, Ashwani [1 ]
Mittal, Rita [2 ]
Surya, Mukesh [1 ]
机构
[1] IGMC, Dept Radiodiag, Shimla 171001, Himachal Prades, India
[2] IGMC, Dept Obstet & Gynecol, KNHM&C, Shimla, India
关键词
Preterm delivery; cervical ripening; elastography; colour code; strain ratio; UTERINE CERVIX; BIRTH; PREGNANCY; LENGTH; RISK; INDUCTION; SUCCESS; WOMEN;
D O I
10.1177/1742271X241277448
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Preterm delivery is a grave and demanding problem that accounts for the major cause of neonatal deaths and long-term morbidities. It remains an unresolved health issue of global dimensions. Cervical elastography is evolving as a useful diagnostic tool for its timely prediction so that individualised management can be done. Aim: To assess the diagnostic accuracy of transvaginal strain cervical elastography in prediction of preterm delivery. Methods: This prospective observational study was conducted from June 2021 to August 2022 in a tertiary care institute of North India. A total of 75 low-risk asymptomatic women were included. Transvaginal ultrasound was performed for the cervical length in the second and third trimesters. In addition, we collected strain elastography data such as colour codes from six regions of the cervix, that is, at the anterior and posterior lips of internal os, middle one-third of the cervix and the external os, and the strain ratios from these three cervical levels were also calculated. Then these parameters were compared with cervical length, second and third trimester groups and also with preterm and term delivery groups. Result: The red colour (soft colour) at the anterior lip of internal os was the best predictor of preterm delivery in our study with a sensitivity and specificity of 63.64% and 96.87%, respectively. The elastography strain ratio of >2 at the internal os and cervical length <= 2.8 cm were the additional predictors for the same. Conclusion: Cervical elastography can serve as a potential and reliable predictor for preterm delivery.
引用
收藏
页码:35 / 47
页数:14
相关论文
共 27 条
  • [1] Diagnostic accuracy of cervical elastography for predicting preterm delivery: Systematic review and meta-analysis
    Sun, Hui
    Lv, Qifeng
    Liu, Tingting
    Zhang, Nan
    Shi, Fengfeng
    SCOTTISH MEDICAL JOURNAL, 2023, 68 (03) : 110 - 120
  • [2] Value of cervical strain in ultrasound elastography as a predictor of spontaneous preterm delivery
    Abdallah, Yasmin Essam E. L. Din Mohamed
    Mostafa, Yassmen Hassan Ahmed
    Gaafar, Hassan Moustafa Ismaeil
    Hegazy, Rania Mohamed Abbas
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01)
  • [3] Diagnostic accuracy of cervical elastography in predicting preterm delivery A systematic review and meta-analysis
    Wang, Bo
    Zhang, Yong
    Chen, Shuangshuang
    Xiang, Xiaowei
    Wen, Juan
    Yi, Mei
    He, Baiyun
    Hu, Bing
    MEDICINE, 2019, 98 (29)
  • [4] Value of cervical strain in ultrasound elastography as a predictor of spontaneous preterm delivery
    Yasmin Essam EL Din Mohamed Abdallah
    Yassmen Hassan Ahmed Mostafa
    Hassan Moustafa Ismaeil Gaafar
    Rania Mohamed Abbas Hegazy
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [5] Addition of Cervical Elastography May Increase Preterm Delivery Prediction Performance in Pregnant Women with Short Cervix: a Prospective Study
    Park, Hyun Soo
    Kwon, Hayan
    Kwak, Dong Wook
    Kim, Moon Young
    Seol, Hyun-Joo
    Hong, Joon-Seok
    Shim, Jae-Yoon
    Choi, Sae-Kyung
    Hwang, Han-Sung
    Oh, Min Jeong
    Cho, Geum Joon
    Kim, Kunwoo
    Oh, Soo-young
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2019, 34 (09)
  • [6] Elastography for predicting preterm delivery in patients with short cervical length at 18-22 weeks of gestation: a prospective observational study
    Wozniak, Slawomir
    Czuczwar, Piotr
    Szkodziak, Piotr
    Wrona, Wojciech
    Paszkowski, Tomasz
    GINEKOLOGIA POLSKA, 2015, 86 (06) : 442 - 447
  • [7] Cervical shear wave elastography as a predictor of preterm delivery during 18-24 weeks of pregnancy
    Suthasmalee, Sasiwan
    Moungmaithong, Sakita
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2019, 45 (11) : 2158 - 2168
  • [8] Factors Leading to Early Preterm Premature Rupture of Membranes in a Tertiary Care Centre in Eastern India: A Prospective Study
    Sahu, Manisha
    Panda, Ritimukta
    Das, Sasmita
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2020, 14 (06) : QC01 - QC05
  • [9] Second-trimester transvaginal ultrasound measurement of cervical length for prediction of preterm birth: a blinded prospective multicentre diagnostic accuracy study
    Kuusela, P.
    Jacobsson, B.
    Hagberg, H.
    Fadl, H.
    Lindgren, P.
    Wesstrom, J.
    Wennerholm, U-B
    Valentin, L.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2021, 128 (02) : 195 - 206
  • [10] Mode of delivery for singleton extreme preterm breech fetuses: A 10year retrospective review from a single tertiary obstetric centre
    Hills, Frances
    Way, Mandy
    Sekar, Renuka
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 2018, 58 (02) : 178 - 184