Benchmarking of a new integrated 3D dosimetry system against Monte Carlo calculations and an established optical CT scanner

被引:0
作者
Lakrad, Kawtar [1 ,2 ]
Oldham, Mark [1 ]
Quinn, Benjamin [3 ]
Adamson, Justus [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27710 USA
[2] Hassan II Univ, Dept Phys, Casablanca, Morocco
[3] Modus Med Devices Inc IBA QUASAR, London, ON, Canada
关键词
3D dosimetry; 3D gamma analysis; optical scanner; radiochromic dosimeters; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; GEL; VERIFICATION; DELIVERY;
D O I
10.1002/mp.17773
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundAdvanced radiation therapy techniques, including intensity-modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS), adaptive therapy, and proton therapy, offer high precision in delivering radiation doses to tumors while minimizing exposure to surrounding healthy tissues. These sophisticated methods necessitate stringent quality assurance (QA) measures to ensure their accuracy and safety. Three-dimensional (3D) dosimetry systems have the potential to play an important role in this context for verifying dose distributions in a comprehensive manner but have not been widely implemented partially due to a lack of streamlined systems that include dosimeter, readout, and analysis.PurposeThe ClearView radiochromic dosimeter, the Vista 16 Optical CT scanner, and the VistaAce analysis software have the potential as a fully integrated 3D dosimetry tool for commissioning and verifying complex radiotherapy treatment plans. We aim to benchmark this integrated 3D dosimetry system and investigate its clinical utility.MethodsThe performance of this system was benchmarked against an independent Monte Carlo dose calculation software, the Duke Large Field of View Optical CT Scanner (DLOS), and an open-source analysis software (3D Slicer v4.13). We measured two simple radiotherapy plans and a selection from the AAPM (American Association of Physicists in Medicine) Task Group 119 IMRT commissioning tests. Treatment plans were prepared within the Eclipse planning system (AAA v15.6.03) after which a Varian Truebeam linac was used to deliver the treatment plans. Vista 16 was used to reconstruct the measured 3D dose distribution which was compared to the dose distribution obtained from an independent Monte Carlo-based dose calculation algorithm, as well as the 3D dose distribution reconstructed using the well-established DLOS. Image registration, conversion from optical density to dose, and comparative analysis were done using the VistaAce software and validated against results obtained using 3D Slicer for a subset of tests.ResultsClearView dosimeters exhibited a linear dose-response up to 60 Gy. For the 3-field benchmarking irradiation, the agreement (2%/2 mm 3D global gamma Index, 10% threshold) between ClearView/VistaAce versus the TPS and Monte Carlo was 97.8% and 98.8%, respectively. For the AAPM TG119 mock head and neck plan, the agreement (2%/2 mm) with the treatment planning system and Monte Carlo was 99.1% and 95.1%, respectively. For the TG119 mock prostate, the agreement was 99.7% and 98.9%, respectively. Agreement for the ClearView/ Vista 16 dose reconstruction was equivalent or superior to that of the ClearView/DLOS reconstruction for the benchmarking irradiations.ConclusionThe ClearView/Vista 3D dosimetry system demonstrated robust performance in measuring and verifying realistic clinical dose distributions, with good agreement with an independent Monte Carlo algorithm and equivalent or better agreement than DLOS. The system's integrated approach, combining dosimetry, scanning, and analysis, streamlines QA processes in advanced radiation therapy, potentially enhancing clinical practice by providing consistent and accurate dosimetric verification.
引用
收藏
页码:3377 / 3390
页数:14
相关论文
共 35 条
[1]   Characterisation of PRESAGE™:: A new 3-D radiochromic solid polymer dosemeter for ionising radiation [J].
Adamovics, J. ;
Maryanski, M. J. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :107-112
[2]   Towards comprehensive characterization of Cs-137 Seeds using PRESAGE® dosimetry with optical tomography [J].
Adamson, J. ;
Yang, Y. ;
Rankine, L. ;
Newton, J. ;
Adamovics, J. ;
Craciunescu, O. ;
Oldham, M. .
7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
[3]  
Adamson Justus, 2023, Z Med Phys, DOI 10.1016/j.zemedi.2023.08.004
[4]   Streamlined open-source gel dosimetry analysis in 3D slicer [J].
Alexander, K. M. ;
Pinter, C. ;
Fichtinger, G. ;
Olding, T. ;
Schreiner, L. J. .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (04)
[5]   Cross-Validation of 3D Gamma Comparison Tools [J].
Alexander, K. M. ;
Jechel, C. ;
Pinter, C. ;
Salomons, G. ;
Lasso, A. ;
Fichtinger, G. ;
Schreiner, L. J. .
MEDICAL PHYSICS, 2015, 42 (06) :3385-3385
[6]  
[Anonymous], CLEARVIEW 3D DOSIMET
[7]   Tetrazolium salt monomers for gel dosimetry II: Dosimetric characterization of the ClearView™ 3D dosimeter [J].
Ascencion, Yudy ;
Dietrich, Jennifer ;
Mequanint, Kibret ;
Penev, Kalin I. .
9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
[8]   Three-dimensional dose verification for intensity-modulated radiation therapy in the radiological physics centre head-and-neck phantom using optical computed tomography scans of ferrous xylenol-orange gel dosimeters [J].
Babic, Steven ;
Battista, Jerry ;
Jordan, Kevin .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1281-1291
[9]   Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study [J].
Colnot, J. ;
Huet, C. ;
Gschwind, R. ;
Clairand, I .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 :154-164
[10]   Three-Dimensional Dosimetry by Optical-CT and Radiochromic Gel Dosimeter of a Multiple Isocenter Craniospinal Radiation Therapy Procedure [J].
da Silveira, Matheus Antonio ;
Pavoni, Juliana Fernandes ;
Bruno, Alexandre Colello ;
Arruda, Gustavo Viani ;
Baffa, Oswaldo .
GELS, 2022, 8 (09)