Development of a multiresidue quantitative screening method based on pulsed amperometric detection at a glassy carbon electrode for sulfonamides monitoring in foodstuffs of animal origin

被引:0
|
作者
Croce, Lucia [1 ]
Palermo, Carmen [2 ]
Centonze, Diego [1 ]
机构
[1] Univ Foggia, Dept Med & Surg Sci, Via Napoli 25, I-71122 Foggia, Italy
[2] Univ Foggia, Dept Clin & Expt Med, Via Napoli 25, I-71122 Foggia, Italy
关键词
Sulfa drugs; Cyclic voltammetry; PAD; Bare glassy carbon electrode; RP-HPLC; Milk; PERFORMANCE LIQUID-CHROMATOGRAPHY; DIAMOND ELECTRODES; FOOD ANIMALS; SAMPLES; RESIDUES; HPLC; SULFADIAZINE; VALIDATION; PHARMACEUTICALS; SULFAMERAZINE;
D O I
10.1016/j.talanta.2025.127800
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new effective quantitative screening method was developed to detect sulfonamides (SAs) in foodstuffs of animal origin. The method was based on pulsed amperometric detection (PAD) at a glassy carbon electrode (GCE) coupled with a reversed-phase high performance liquid chromatographic separation (RP-HPLC). First, SAs electrochemical behaviour at GCE was investigated by cyclic voltammetry (CV) experiments. In the light of the CV results, a new three-step waveform for pulsed amperometric detection of SAs was designed and optimized by performing flow injection analysis (FIA) of SAs standard solutions. The optimized PAD waveform ensured an excellent response stability and sensitivity with respect to the direct current detection at constant potential. PAD was then applied to detect SAs after RP-HPLC in gradient mode by using a typical organic mobile phase containing acetate buffer, acetonitrile and methanol. The developed method showed, for all the SAs investigated, very low limits of detection and quantification, in the range 2.1-2.7 mu g L- 1 and 6.9-9.0 mu g L- 1, respectively, and a wide linear range (up to 0.5 mg L- 1). Method selectivity was tested by comparing the chromatograms of SAs mix standard solutions, blank purified milk samples (without SAs) and spiked purified milk samples. Excellent values of precision under repeatability (1.0-5.0 %, n = 6) and within-laboratory reproducibility (11.2-18.6 %, n = 18) conditions, and recoveries (94-105 %) were obtained.
引用
收藏
页数:9
相关论文
共 9 条
  • [1] Determination of sulfonamides in milk samples by HPLC with amperometric detection using a glassy carbon electrode modified with multiwalled carbon nanotubes
    Maria Bueno, Ana
    Maria Contento, Ana
    Rios, Angel
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (04) : 382 - 389
  • [2] A Simple and Sensitive Method for the Amperometric Detection of Trace Chromium(VI) Based on Prussian Blue Modified Glassy Carbon Electrode
    Xing, Sujie
    Xu, He
    Shi, Guoyue
    Chen, Junshui
    Zeng, Liping
    Jin, Litong
    ELECTROANALYSIS, 2009, 21 (15) : 1678 - 1684
  • [3] Development of a Liquid Chromatography/Amperometric Detection Method for the Determination of Multiresidue Sulfonamide Antibiotics in Meat-Based Baby Foods
    Casella, Innocenzo G.
    Contursi, Michela
    Gioia, Daniele
    ELECTROANALYSIS, 2012, 24 (11) : 2125 - 2133
  • [4] A Flow Injection Amperometric Sensor for Nitrate Detection Based on Cu Foam/Ordered Mesoporous Carbon Modified Glassy Carbon Electrode
    Junlapak, Nuttakorn
    Numnuam, Apon
    Nontipichet, Natha
    Kangkamano, Tawatchai
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    Khumngern, Suntisak
    CHEMNANOMAT, 2024, 10 (06)
  • [5] Determination of β-Agonists in Urine Samples at Low μg/kg Levels by Means of Pulsed Amperometric Detection at a Glassy Carbon Electrode Coupled with RP-LC
    Mentana, Annalisa
    Palermo, Carmen
    Centonze, Diego
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [6] A Simple Flow Amperometric Electrochemical Biosensor Based on Chitosan Scaffolds and Gold Nanowires Modified on a Glassy Carbon Electrode for Detection of Glutamate in Food Products
    Kitikul, Jiraporn
    Satienperakul, Sakchai
    Preechaworapun, Anchana
    Pookmanee, Pusit
    Tangkuaram, Tanin
    ELECTROANALYSIS, 2017, 29 (01) : 264 - 271
  • [7] Development of Electrochemical Sensor Based on Glassy Carbon Electrode Modified with a Molecularly Imprinted Copolymer and its Application for Detection of Repaglinide
    Roushani, Mahmoud
    Jalilian, Zeynab
    ELECTROANALYSIS, 2018, 30 (11) : 2712 - 2718
  • [8] Validation of a screening method for the rapid control of sulfonamide residues based on electrochemical detection using multiwalled carbon nanotubes-glassy carbon electrodes
    Maria Bueno, Ana
    Maria Contento, Ana
    Rios, Angel
    ANALYTICAL METHODS, 2013, 5 (23) : 6821 - 6829
  • [9] Development of a new electrochemical sensor based on nafion/cobalt doped bismuth ferrite nanoparticle modified glassy carbon electrode for detection of hydrogen peroxide
    Alemayehu, Dagim
    Bitew, Zelalem
    Yohannes, Yonas Beyene
    SENSING AND BIO-SENSING RESEARCH, 2023, 42