Design and Validation of a Very Low-Power Phasor Measurement Unit for the Distribution System

被引:0
|
作者
Lythgoe, Zachary J. [1 ]
Long, Thomas F. [1 ]
Buchholz, Michael J. [1 ]
Livernois, Anthony R. [1 ,2 ]
Kanuteh, Kebba [1 ,3 ]
Allee, David R. [1 ]
Pal, Anamitra [1 ]
Graham, Ian R. [4 ]
Drummond, Zachary D. [5 ]
机构
[1] Arizona State Univ, Dept Elect Comp & Energy Engn, Tempe, AZ 85287 USA
[2] BG Prod Inc, Wichita, KS 67213 USA
[3] Naval Surface Warfare Ctr, Philadelphia, PA 19112 USA
[4] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[5] DEVCOM Army Res Lab, Adelphi, MD 20783 USA
关键词
Phasor measurement units; Sensors; Voltage measurement; Low-pass filters; Conductors; Power demand; Field programmable gate arrays; Batteries; Signal processing algorithms; Sensor arrays; Digital signal processing; distribution system; field-programmable gate array (FPGA); phasor measurement unit (PMU); smart grid;
D O I
10.1109/TIA.2024.3524494
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Phasor measurement units (PMUs) provide a high-resolution view of the power system at the locations where they are placed. As such, it is desirable to place them in bulk in low-voltage distribution circuits. However, the power consumption of a PMU/micro-PMU is on the order of Watts (W), requiring an external power supply, which both increases the overall cost as well as limits the locations where they can be placed. This work details the hardware design of a PMU capable of measuring and reporting voltage and current phasors for a single-phase system at an average power consumption of only 30.8 mW-one to two orders of magnitude lower than existing academic and commercial PMUs. This enables the proposed PMU to run for two weeks using an 11-Wh battery or indefinitely if paired with an inexpensive solar panel. A test bench developed in accordance with the 2018 IEC/IEEE 60255-118-1 PMU Standard confirms the accuracy of this PMU, and a Fluke 6135A PMU calibration system evaluates its performance under realistic conditions. Given its low power consumption, the proposed design is expected to accelerate adoption of PMUs in modern distribution grids.
引用
收藏
页码:3553 / 3562
页数:10
相关论文
共 50 条
  • [41] Power system responses to geomagnetic disturbances recognized using phasor measurement recordings
    Chen, Jian
    Liu, Chunming
    Wang, Maohai
    Wang, Tong
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 113 : 932 - 940
  • [42] A new design of low-power portable digital ionosonde
    Huang, Shuo
    Zhao, Zhengyu
    Yang, Guobing
    Chen, Gang
    Li, Ting
    Li, Ning
    Yang, Junjie
    ADVANCES IN SPACE RESEARCH, 2013, 51 (03) : 388 - 394
  • [43] Identification of Reduced Models of Power System Areas using Phasor Measurement Units
    Vahidnia, Arash
    Ledwich, Gerard
    Palmer, Edward
    Ghosh, Arindam
    2013 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2013,
  • [44] Low-Power SDR Design on an FPGA for Intersatellite Communications
    Cai, Xin
    Zhou, Mingda
    Xia, Tian
    Fong, Wai H.
    Lee, Wing-Tsz
    Huang, Xinming
    IEEE TRANSACTIONS ON VERY LARGE SCALE INTEGRATION (VLSI) SYSTEMS, 2018, 26 (11) : 2419 - 2430
  • [45] A Wireless Low-Power Single-Unit Wearable System for Continuous Early Warning Score Calculation
    Bellier, Pierre
    Wallant, Dorothee Coppieters't
    van den Bongarth, Henri
    Bijnens, Wouter
    Aarts, Jos
    Vandenryt, Thijs
    Thoelen, Ronald
    Duflot, Patrick
    Dupont, Francois
    Redoute, Jean-Michel
    IEEE SENSORS JOURNAL, 2023, 23 (11) : 12171 - 12180
  • [46] Automated measurement system for power distribution
    Marino, P
    Siguenza, C
    Poza, F
    Vazquez, F
    Machado, F
    2003 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 2003, : 329 - 332
  • [47] Review of the Techniques of the Data Analytics and Islanding Detection of Distribution Systems Using Phasor Measurement Unit Data
    Arefin, Ahmed Amirul
    Baba, Maveeya
    Singh, Narinderjit Singh Sawaran
    Nor, Nursyarizal Bin Mohd
    Sheikh, Muhammad Aman
    Kannan, Ramani
    Abro, Ghulam E. Mustafa
    Mathur, Nirbhay
    ELECTRONICS, 2022, 11 (18)
  • [48] Development and Implementation of a Phasor Measurement Unit for Real-Time Monitoring, Control and Protection of Power Systems
    Salehi, V.
    Mazloomzadeh, A.
    Mohammed, O.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [49] Resilient Frequency Estimation for Renewable Power Generation Against Phasor Measurement Unit and Communication Link Failures
    Hu, Zhijian
    Su, Rong
    Zhang, Kai
    Wang, Ruiping
    Ma, Renjie
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2025, 72 (01) : 233 - 237
  • [50] Design and Characterization of a Combined Low-Power Voltage and Current Instrument Transformer for Low-Voltage Applications
    Huangfu, Youpeng
    Faifer, Marco
    Ottoboni, Roberto
    Toscani, Sergio
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73