Narrative review: evolution in device technology and advances in surgical techniques on AMS 800 device in the last 50 years

被引:0
作者
Chung, Eric [1 ,2 ,3 ]
机构
[1] Univ Queensland, Princess Alexandra Hosp, Dept Urol, Brisbane, Qld, Australia
[2] Macquarie Univ Hosp, Dept Urol, Sydney, Australia
[3] AndroUrol Ctr, Suite 3,530 Boundary St, Brisbane, Qld 4000, Australia
关键词
Artificial urinary sphincter (AUS); stress incontinence; surgical techniques; technology advances; ARTIFICIAL URINARY SPHINCTER; FUNCTIONAL OUTCOMES; MALE STRESS; INCONTINENCE; IMPLANTATION; WOMEN; EXPERIENCE; MEN; PLACEMENT; REVISION;
D O I
10.21037/tau-23-10
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
Background and Objective: The current AMS 800 artificial urinary sphincter (AUS) device is designed to simulate the function of the biological urinary sphincter to prevent urinary flow through mucosal coaptation, compression, and pressure transmission. The challenges in designing the AMS 800 device involve not only the mechanical operation of the artificial sphincter device but also producing a device that is effective, safe, and durable for patients in the long term. The following article provides a narrative review regarding the evolution and development of the AMS 800 devices over the years and evaluates the advances in surgical techniques relating to AMS 800 implantation. Methods: Available literature pertaining to the AMS 800 device was reviewed from the MEDLINE and EMBASE databases between 1 January 2000 to 31 December 2022. Emphasis is placed on key scientific publications including previous reviews and clinical guidelines relevant to AMS 800 device(s) and surgical techniques. Key Content and Findings: From the engineering point of view, the current AMS 800 device is ingenious and has stood the test of time. The basic design of this modern AUS consists of 3 separate components namely a pressure regulating balloon (PRB), an inflatable cuff, and a control pump. Continued innovations in device design and technology, coupled with refinements in surgical techniques over the past 5 decades have ensured that the AMS 800 device is and remains the standard of care in male stress urinary incontinence. While the long-term AMS 800 efficacy, safety, and durability are well documented, it is not without its limitations and complications. Mechanical and non-mechanical complications can occur especially in high-risk populations (such as in radiated patients) despite strict adherence to surgical principles and manufacturer's guidelines. Conclusions: Continued innovations in device design, technology, and surgical techniques have ensured that the AMS 800 device is an effective and safe treatment for male stress urinary incontinence (SUI). Future directions in the treatment of male SUI likely reside in cellular regenerative therapy and nanotechnology to restore, replace, or simulate the damaged native urinary sphincter.
引用
收藏
页码:1657 / 1665
页数:9
相关论文
共 52 条
  • [51] Robot-assisted laparoscopic artificial urinary sphincter insertion in men with neurogenic stress urinary incontinence
    Yates, David R.
    Phe, Veronique
    Roupret, Morgan
    Vaessen, Christophe
    Parra, Jerome
    Mozer, Pierre
    Chartier-Kastler, Emmanuel
    [J]. BJU INTERNATIONAL, 2013, 111 (07) : 1175 - 1179
  • [52] zsimplants, About us