Background and Objective: The current AMS 800 artificial urinary sphincter (AUS) device is designed to simulate the function of the biological urinary sphincter to prevent urinary flow through mucosal coaptation, compression, and pressure transmission. The challenges in designing the AMS 800 device involve not only the mechanical operation of the artificial sphincter device but also producing a device that is effective, safe, and durable for patients in the long term. The following article provides a narrative review regarding the evolution and development of the AMS 800 devices over the years and evaluates the advances in surgical techniques relating to AMS 800 implantation. Methods: Available literature pertaining to the AMS 800 device was reviewed from the MEDLINE and EMBASE databases between 1 January 2000 to 31 December 2022. Emphasis is placed on key scientific publications including previous reviews and clinical guidelines relevant to AMS 800 device(s) and surgical techniques. Key Content and Findings: From the engineering point of view, the current AMS 800 device is ingenious and has stood the test of time. The basic design of this modern AUS consists of 3 separate components namely a pressure regulating balloon (PRB), an inflatable cuff, and a control pump. Continued innovations in device design and technology, coupled with refinements in surgical techniques over the past 5 decades have ensured that the AMS 800 device is and remains the standard of care in male stress urinary incontinence. While the long-term AMS 800 efficacy, safety, and durability are well documented, it is not without its limitations and complications. Mechanical and non-mechanical complications can occur especially in high-risk populations (such as in radiated patients) despite strict adherence to surgical principles and manufacturer's guidelines. Conclusions: Continued innovations in device design, technology, and surgical techniques have ensured that the AMS 800 device is an effective and safe treatment for male stress urinary incontinence (SUI). Future directions in the treatment of male SUI likely reside in cellular regenerative therapy and nanotechnology to restore, replace, or simulate the damaged native urinary sphincter.
引用
收藏
页码:1657 / 1665
页数:9
相关论文
共 52 条
  • [1] Artificial Urinary Sphincter: Report of the 2015 Consensus Conference
    Biardeau, X.
    Aharony, S.
    Campeau, L.
    Corcos, J.
    [J]. NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S8 - S24
  • [2] Montreal electronic artificial urinary sphincters: Our futuristic alternatives to the AMS800™
    Biardeau, Xavier
    Hached, Sami
    Loutochin, Oleg
    Campeau, Lysanne
    Sawan, Mohamad
    Corcos, Jacques
    [J]. CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2017, 11 (10): : E396 - E404
  • [3] Robot-assisted Laparoscopic Approach for Artificial Urinary Sphincter Implantation in 11 Women with Urinary Stress Incontinence: Surgical Technique and Initial Experience
    Biardeau, Xavier
    Rizk, Jerome
    Marcelli, Francois
    Flamand, Vincent
    [J]. EUROPEAN UROLOGY, 2015, 67 (05) : 937 - 942
  • [4] Bostonscientific, About us
  • [5] Artificial urinary sphincter (AMS 800) implantation for women with intrinsic sphincter deficiency: a technique for insiders?
    Chartier-Kastler, Emmanuel
    Van Kerrebroeck, Philip
    Olianas, Roberto
    Cosson, Michel
    Mandron, Eric
    Delorme, Emmanuel
    Richard, Francois
    [J]. BJU INTERNATIONAL, 2011, 107 (10) : 1618 - 1626
  • [6] Choe JM, 1997, J LONG-TERM EFF MED, V7, P75
  • [7] The Asia-Pacific AMS800 artificial urinary sphincter consensus statement
    Chung, Eric
    Liao, Limin
    Kim, Jang Hwan
    Wang, Zhong
    Kitta, Takeya
    Lin, Alex Tong-Long
    Lee, Kyu-Sung
    Ye, Liefu
    Chu, Peggy
    Kaiho, Yasuhiro
    Takei, Mineo
    Jiang, Hai
    Lee, Joe
    Masuda, Hitoshi
    Tse, Vincent
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2023, 30 (02) : 128 - 138
  • [9] Chung E, 2017, AUST FAM PHYSICIAN, V46, P661