Acoustics; Tomography; Imaging; Metals; Reflection; Liquids; Ultrasonic transducer arrays; Ultrasonic imaging; Attenuation; Impedance; Electromagnetic acoustic transducer (EMAT) array; full matrix capture (FMC); guided wave; total focusing method (TFM); ultrasonic tomography (UT) system; NEUTRON-RADIOGRAPHY; FULL MATRIX;
D O I
10.1109/TIM.2025.3527608
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The gas-liquid two-phase flow tomography technique has significant value for industrial process monitoring. However, the harsh environment and metal pipes present a challenge that limits the applicability of existing techniques. To address the challenge of gas-liquid two-phase flow tomography in metal pipes, an ultrasonic tomography (UT) system based on electromagnetic acoustic transducer (EMAT) technology was designed and developed to effectively realize process tomography. By considering the installation distance, guided wave mode, and transducer coil proportion of the EMAT array, the optimal overall scheme of the EMAT array can be obtained through finite element (FE) simulation. Through experimental tests, the consistency of each channel of the EMAT array is evaluated and normalized in order to reduce the artifacts that are caused by channel inconsistency. In order to achieve tomography in metal pipes in static experiments, a revised total focusing method (TFM) algorithm has been developed within the UT system, utilizing the EMAT guided wave. The analysis of the imaging effect and the sensitivity distribution in the imaging region has led to the formulation of proposals regarding the limitations of the system and potential improvement methods.
引用
收藏
页数:9
相关论文
共 18 条
  • [1] Review of ultrasonic measurement methods for two-phase flow
    Fan, Jinhui
    Wang, Fei
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (09)
  • [2] Flow noise characterization of gas-liquid two-phase flow based on acoustic emission
    Fang, Lide
    Liang, Yujiao
    Lu, Qinghua
    Li, Xiaoting
    Liu, Ran
    Wang, Xiaojie
    [J]. MEASUREMENT, 2013, 46 (10) : 3887 - 3897
  • [3] Simulative and Experimental Studies: Void Fraction Detection in a Bubble Column of a Conducting Pipe
    Goh, Chiew Loon
    Ruzairi, Abdul Rahim
    Hafiz, Fazalul Rahiman
    Tee, Zhen Cong
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (12) : 9636 - 9645
  • [4] Cross-sectional void fraction distribution measurements in a vertical annulus two-phase flow by high speed X-ray computed tomography and real-time neutron radiography techniques
    Harvel, GD
    Hori, K
    Kawanishi, K
    Chang, JS
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 1999, 10 (04) : 259 - 266
  • [5] Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation
    Holmes, C
    Drinkwater, BW
    Wilcox, PD
    [J]. NDT & E INTERNATIONAL, 2005, 38 (08) : 701 - 711
  • [6] A Sensitivity Map Deformation Method for Image Quality Improvement of Ultrasonic Tomography
    Hu, Jingyi
    Qin, Yixin
    Li, Nan
    Wang, Lina
    Jia, Jiabin
    Yang, Yunjie
    [J]. IEEE SENSORS JOURNAL, 2024, 24 (08) : 12632 - 12641
  • [7] Khairi M. T. M., A review on applications of optical tomography in industrial process
  • [8] A real-time ultrasound process tomography system using a reflection-mode reconstruction technique
    Langener, Sascha
    Vogt, Michael
    Ermert, Helmut
    Musch, Thomas
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 107 - 115
  • [9] A Novel Method for the Image Quality Improvement of Ultrasonic Tomography
    Li, Nan
    Wang, Lina
    Jia, Jiabin
    Yang, Yunjie
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
  • [10] Li Z., 2006, IEEE Sensors J., V6, P1706, DOI [10.1109/JSEN.2006.884549, DOI 10.1109/JSEN.2006.884549]