Interobserver reliability of sonographic measurement of inferior vena cava and aorta parameters in fasting children in the perioperative period: A prospective observational study

被引:0
|
作者
Thaware, Pooja [1 ]
Choudhary, Pooja [2 ]
Ahmad, Zainab [3 ]
Jangid, Surendra [4 ]
Ahmad, Reyaz [5 ]
Kumar, Amber [6 ]
Waindeskar, Vaishali [3 ]
机构
[1] All India Inst Med Sci, Dept Trauma & Emergency Med, Bhopal, Madhya Pradesh, India
[2] All India Inst Med Sci, Dept Anesthesiol & Crit Care, New Delhi, India
[3] All India Inst Med Sci, Dept Anesthesiol & Crit Care, Bhopal, Madhya Pradesh, India
[4] All India Inst Med Sci, Dept Anesthesiol & Crit Care, Raebareli, Uttar Pradesh, India
[5] All India Inst Med Sci, Dept Pediat Surg, Bhopal, Madhya Pradesh, India
[6] All India Inst Med Sci, Dept Pediat, Bhopal, Madhya Pradesh, India
关键词
Aorta; child; inferiorvena cava; observer variation; sonography; ultrasonographic measurements; INTERRATER RELIABILITY; ULTRASOUND;
D O I
10.4103/joacp.joacp_121_24
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background and Aims:Point-of-care ultrasound conducted by anesthesiologists plays a crucial role in ensuring the safety of anesthesia. This study aims to evaluate the interobserver reliability of ultrasound measurements of the inferior vena cava (IVC) and aorta diameters in fasting pediatric patients undergoing spontaneous and controlled ventilation. Despite the prevalent use of indices for intravascular volume assessment, their accuracy varies depending on the observer's expertise, particularly in pediatric cases. This research seeks to provide valuable insights into the interobserver reliability of ultrasound measurements in pediatric patients. Material and Methods:A single-center prospective observational study was conducted involving pediatric patients aged 1-12 years undergoing elective surgery. Ethical approval and written consent were obtained, with exclusions for major cardiovascular issues. Ultrasound measurements of IVC and aorta were performed by two observers during spontaneous and controlled ventilation in the subxiphoid transabdominal long-axis view. Reliability was assessed through statistical analyses, including the intraclass correlation coefficient and Bland-Altman analysis. Results:Mean values of IVC and aorta diameters were summarized for both observers during different ventilation modes. The intraclass correlation coefficient indicated excellent to good agreement between the observers for both spontaneous and controlled ventilation scenarios. Bland-Altman analysis revealed no fixed or proportional errors, confirming the reliability of the measurements. Conclusions:This study establishes the reliability of ultrasound measurements for assessing IVC and aorta in subxiphoid transabdominal long-axis view. The findings highlight the potential of this technique in pediatric anesthesia, even after brief training, providing valuable insights for clinical practice.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 17 条
  • [1] Sonographic Measurements of Inferior Vena Cava, Aorta, and IVC/Aorta Ratio in Healthy Children
    Horoz, O. Ozgur
    Yildizdas, D.
    Aslan, N.
    Coban, Y.
    Misirlioglu, M.
    Haytoglu, Z.
    Sertdemir, Y.
    Gundeslioglu, O. O.
    Soyupak, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2022, 25 (06) : 825 - 832
  • [2] Comparison of sonographic inferior vena cava and aorta indexes during fluid administered in children
    Choi, Yun Ang
    Kwon, Hyuksool
    Lee, Jin Hee
    Jung, Jae Yun
    Choi, Yoo Jin
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2018, 36 (09) : 1529 - 1533
  • [3] Preoperative and Postoperative Assessment of Ultrasonographic Measurement of Inferior Vena Cava: A Prospective, Observational Study
    Kaydu, Ayhan
    Gokcek, Erhan
    JOURNAL OF CLINICAL MEDICINE, 2018, 7 (06):
  • [4] Correlation of sonographic inferior vena cava and aorta diameter ratio with dehydration in Nigerian children
    Adewumi, A. A.
    Braimoh, K. T.
    Adesiyun, O. A. M.
    Ololu-Zubair, H. T.
    Idowu, B. M.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2019, 22 (07) : 950 - 956
  • [5] Central Venous Pressure Estimation by Ultrasound Measurement of Inferior Vena Cava and Aorta Diameters in Pediatric Critical Patients: An Observational Study
    Mercolini, Federico
    Di Leo, Valentina
    Bordin, Giulia
    Melotti, Roberto
    Sperotto, Francesca
    Pettenazzo, Andrea
    Amigoni, Angela
    Tosoni, Alvise
    PEDIATRIC CRITICAL CARE MEDICINE, 2021, 22 (01) : E1 - E9
  • [6] Role of Inferior Vena Cava Parameters as Predictors of Fluid Responsiveness in Pediatric Septic Shock: A Prospective Study
    EL-Nawawy, Ahmed Ahmed
    Omar, Omneya Magdy
    Hassouna, Hadir Mohamed
    JOURNAL OF CHILD SCIENCE, 2021, 11 (01): : E49 - E54
  • [7] Accuracy of preoperative evaluation of inferior vena cava collapsibility index and caval aorta index for prediction of hypotension after induction of general anesthesia: a prospective observational study
    Omar, Heba
    Moamen, Ahmed
    Abdelhamid, Bassant Mohamed
    Rady, Ashraf
    Farouk, Inas
    ANAESTHESIA PAIN & INTENSIVE CARE, 2023, 27 (04) : 449 - 455
  • [8] Efficacy of inferior vena cava collapsibility index and caval aorta index in predicting the incidence of hypotension after spinal anaesthesia- A prospective, blinded, observational study
    Lal, Jatin
    Jain, Mamta
    Rahul
    Singh, Anish Kumar
    Bansal, Teena
    Vashisth, Sumedha
    INDIAN JOURNAL OF ANAESTHESIA, 2023, 67 (06) : 523 - 529
  • [9] Inferior vena cava collapsibility index for the assessment of fluid responsiveness among spontaneously breathing preoperative fasting patients-An observational study
    Kalshetty, Kiran
    Jahan, Nikahat
    Setlur, Rangraj
    Jaiswal, Alok
    Dwivedi, Deepak
    JOURNAL OF MARINE MEDICAL SOCIETY, 2020, 22 (02) : 151 - 155
  • [10] Does Bedside Sonographic Measurement of the Inferior Vena Cava Diameter Correlate With Central Venous Pressure in the Assessment of Intravascular Volume in Children?
    Ng, Lorraine
    Khine, Hnin
    Taragin, Benjamin H.
    Avner, Jeffrey R.
    Ushay, Michael
    Nunez, Denise
    PEDIATRIC EMERGENCY CARE, 2013, 29 (03) : 337 - 341