This article presents for the first time a new working electrode with a long service life- the bismuth-plated array of carbon composite microelectrodes for the simple, fast and sensitive determination of quercetin by adsorptive stripping voltammetry. The main experimental conditions were selected. The calibration graph was linear from 1 x 10-9 to 2 x 10-8 mol L-1 with an accumulation time of 60 s. The detection limit was equal to 4.8 x 10-10 mol L-1. The relative standard deviation for 2 x 10-8 mol L-1 of quercetin was 4.4% (n = 7). Possible interference effects resulting from the presence of other organic and surface active compounds and interfering ions were studied. The developed procedure was successfully applied to determine quercetin in pharmaceutical preparations and the spiked urine samples.
引用
收藏
页数:14
相关论文
共 41 条
  • [1] Cathodic adsorptive stripping voltammetric determination of nalidixic acid in pharmaceuticals, human urine and serum
    Ibrahim, MS
    Shehatta, IS
    Sultan, MR
    TALANTA, 2002, 56 (03) : 471 - 479
  • [2] Cathodic adsorptive stripping voltammetric determination of the antitumor drug rutin in pharmaceuticals, human urine, and blood serum
    Temerk, YM
    Ibrahim, HSM
    Schuhmann, W
    MICROCHIMICA ACTA, 2006, 153 (1-2) : 7 - 13
  • [3] Sensitive adsorptive stripping voltammetric procedure of Imatinib determination in spiked urine samples using solid lead microelectrode
    Geca, Iwona
    Korolczuk, Mieczyslaw
    ELECTROANALYSIS, 2023, 35 (07)
  • [4] Adsorptive Stripping Voltammetric Determination of Imipramine and Amitriptiline at a Nanoclay Composite Carbon Ionic Liquid Electrode
    Eslami, E.
    Farjami, F.
    Azar, P. Aberoomand
    Tehrani, M. Saber
    ELECTROANALYSIS, 2014, 26 (02) : 424 - 431
  • [5] Voltammetric Behavior of Testosterone on Bismuth Film Electrode: Highly Sensitive Determination in Pharmaceuticals and Human Urine by Square-Wave Adsorptive Stripping Voltammetry
    Levent, Abdulkadir
    Altun, Ahmet
    Tas, Suleyman
    Yardim, Yavuz
    Senturk, Zuhre
    ELECTROANALYSIS, 2015, 27 (05) : 1219 - 1228
  • [6] Adsorptive stripping differential pulse voltammetric determination of venlafaxine and desvenlafaxine employing Nafion-carbon nanotube composite glassy carbon electrode
    Sanghavi, Bankim J.
    Srivastava, Ashwini K.
    ELECTROCHIMICA ACTA, 2011, 56 (11) : 4188 - 4196
  • [7] Adsorptive stripping voltammetric determination of chloramphenicol residues in milk samples using reduced graphene oxide sensor
    de Faria, Lucas Vinicius
    Lisboa, Thalles Pedrosa
    Alves, Guilherme Figueira
    Costa Matos, Maria Auxiliadora
    Abarza Munoz, Rodrigo Alejandro
    Matos, Renato Camargo
    ANALYTICAL METHODS, 2021, 13 (47) : 5711 - 5718
  • [8] Adsorptive Stripping Voltammetric Determination of Amaranth and Tartrazine in Drinks and Gelatins Using a Screen-Printed Carbon Electrode
    Perdomo, Yeny
    Arancibia, Veronica
    Garcia-Beltran, Olimpo
    Nagles, Edgar
    SENSORS, 2017, 17 (11)
  • [9] Adsorptive stripping voltammetry for simultaneous determination of hydrochlorothiazide and triamterene in hemodialysis samples using a multi-walled carbon nanotube-modified glassy carbon electrode
    Hudari, Felipe Fantinato
    Souza, Joao Carlos
    Boldrin Zanoni, Maria Valnice
    TALANTA, 2018, 179 : 652 - 657
  • [10] Using of multi-walled carbon nanotubes electrode for adsorptive stripping voltammetric determination of ultratrace levels of RDX explosive in the environmental samples
    Rezaei, Behzad
    Damiri, Sajjad
    JOURNAL OF HAZARDOUS MATERIALS, 2010, 183 (1-3) : 138 - 144