Diagnostic Performance of Visionix VX120+ Platform for Dry Eye Screening

被引:0
作者
Martinez-Plaza, Elena [1 ,2 ]
Barberan-Bernardos, Laura [1 ]
Molina-Martin, Ainhoa [1 ]
Pinero, David P. [1 ,3 ]
机构
[1] Univ Alicante, Dept Opt Pharmacol & Anat, Grp Opt & Visual Percept, Alicante 03690, Spain
[2] Univ Valladolid, Valladolid 47001, Spain
[3] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante 03016, Spain
关键词
tear meniscus height; TMH; tear break-up time; NIBUT; accuracy; Visionix; dry eye; screening; TEAR FILM STABILITY; BREAK-UP TIME; FLUORESCEIN; CORNEAL; DISEASE; VOLUME;
D O I
10.3390/diagnostics14202276
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the accuracy of diagnosing dry eye disease (DED) by using the Visionix VX120+, to establish reference values for tear meniscus height (TMH) and non-invasive break-up time (NIBUT), and to compare the NIBUT measurements with the fluorescein tear break-up time (FBUT), Methods: fifty-eight subjects (34 dry eye and 24 control) were enrolled. The TMH, first NIBUT, and NIBUT50% were evaluated with the Visionix VX120+, and the FBUT was measured with a slit-lamp. The Receiver Operating Characteristic (ROC) curve was used to evaluate the diagnostic performance, and the Bland-Altman method was performed to analyze the agreement. Results: The areas under the curve were 0.62, 0.60, and 0.70 for the TMH, first NIBUT, and NIBUT50%, respectively. The optimal cut-off values (sensitivity, specificity) were 0.29 (0.62, 0.67), 5.05 (0.85, 0.46), and 7.35 (0.65, 0.79) for the TMH, first NIBUT, and NIBUT50%, respectively. The mean differences (lower, upper limits of agreement) were -1.10 (-8.78, 6.58) and 1.55 (-5.68, 8.78) for the first NIBUT vs. FBUT and the NIBUT50% vs. FBUT, respectively. Conclusions: In conclusion, the NIBUT50% can be a useful tool for dry eye screening, with acceptable values of sensitivity and specificity. First, the NIBUT and NIBUT50% should not be used interchangeably with the FBUT.
引用
收藏
页数:9
相关论文
共 9 条
  • [1] Agreement of Tear Break-Up Time and Meniscus Height between Medmont E300 and Visionix VX120+
    Martinez-Plaza, Elena
    Molina-Martin, Ainhoa
    Pinero, David P.
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [2] Diagnostic performance of a tear protein panel in early dry eye
    Versura, Piera
    Bavelloni, Alberto
    Grillini, Marco
    Fresina, Michela
    Campos, Emilio C.
    MOLECULAR VISION, 2013, 19 : 1247 - 1256
  • [3] Performance of Tear Osmolarity Compared to Previous Diagnostic Tests for Dry Eye Diseases
    Versura, P.
    Profazio, V.
    Campos, E. C.
    CURRENT EYE RESEARCH, 2010, 35 (07) : 553 - 564
  • [4] Artificial Intelligence Software for Diabetic Eye Screening: Diagnostic Performance and Impact of Stratification
    Peeters, Freya
    Rommes, Stef
    Elen, Bart
    Gerrits, Nele
    Stalmans, Ingeborg
    Jacob, Julie
    De Boever, Patrick
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (04)
  • [5] Psychometric properties and diagnostic performance of three dry eye questionnaires in Italian: OSDI, OSDI-6, and SPEED
    Facchin, Alessio
    Boccardo, Laura
    OPTOMETRY AND VISION SCIENCE, 2024, 101 (09) : 579 - 588
  • [6] Diagnostic performance of dry eye tests, serology and labial salivary gland biopsy in primary Sjogren's syndrome in an Indian setting
    Johri, Roma
    Peter, Jayanthi
    Peravali, Vishali
    Sandhya, Pulukool
    Danda, Debashish
    David, Sarada
    CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH, 2020, 8 (01): : 301 - 304
  • [7] Discriminative performance of ocular surface staining and lid wiper epitheliopathy in dry eye disease: An investigator-masked, prospective registry-based, diagnostic accuracy study
    Wang, Michael T. M.
    Power, Barry
    Xue, Ally L.
    Craig, Jennifer P.
    OCULAR SURFACE, 2024, 34 : 165 - 172
  • [8] Diagnostic performance of qualitative and quantitative methods of meibomian gland dropout evaluation in dry eye disease: An investigator-masked, randomised crossover study
    Wang, Michael T. M.
    Power, Barry
    Xue, Ally L.
    Kim, Ji Soo
    Craig, Jennifer P.
    CONTACT LENS & ANTERIOR EYE, 2025, 48 (02)
  • [9] Diagnostic performance and optimal cut-off values for tear film lipid layer grading and thickness in dry eye disease: An investigator-masked, randomised crossover study
    Wang, Michael T. M.
    Power, Barry
    Xue, Ally L.
    Craig, Jennifer P.
    OCULAR SURFACE, 2024, 34 : 415 - 417