Use of artificial intelligence to predict outcomes in mild aortic valve stenosis

被引:0
|
作者
Julakanti, Raghav R. [1 ]
Padang, Ratnasari [1 ]
Scott, Christopher G. [2 ]
Dahl, Jordi [1 ]
Al-Shakarchi, Nader J. [3 ]
Metzger, Coby [4 ]
Lanyado, Alon [4 ]
Jackson, John, I [1 ]
Nkomo, Vuyisile T. [1 ]
Pellikka, Patricia A. [1 ]
机构
[1] Mayo Clin, Dept Cardiovasc Med, 200 First St SW, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Med, Rochester, MN USA
[4] Medial EarlySign, Hod Hasharon, Israel
来源
EUROPEAN HEART JOURNAL - DIGITAL HEALTH | 2024年 / 6卷 / 01期
关键词
Artificial intelligence; Aortic stenosis; Echocardiography; Valve disease; Machine learning; RISK;
D O I
10.1093/ehjdh/ztae085
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Aortic stenosis (AS) is a common and progressive disease, which, if left untreated, results in increased morbidity and mortality. Monitoring and follow-up care can be challenging due to significant variability in disease progression. This study aimed to develop machine learning models to predict the risks of disease progression and mortality in patients with mild AS.Methods and results A comprehensive database including 9611 patients with serial transthoracic echocardiograms was collected from a single institution across three clinical sites. The data set included parameters from echocardiograms, electrocardiograms, laboratory values, and diagnosis codes. Data from a single clinical site were preserved as an independent test group. Machine learning models were trained to identify progression to severe stenosis and all-cause mortality and tested in their performance for endpoints at 2 and 5 years. In the independent test group, the AS progression model differentiated those with progression to severe AS within 2 and 5 years with an area under the curve (AUC) of 0.86 for both. The feature of greatest importance was aortic valve mean gradient, followed by other valve haemodynamic measurements including valve area and dimensionless index. The mortality model identified those with mortality within 2 and 5 years with an AUC of 0.84 and 0.87, respectively. Smaller reduced-input validation models had similarly robust findings.Conclusion Machine learning models can be used in patients with mild AS to identify those at high risk of disease progression and mortality. Implementation of such models may facilitate real-time, patient-specific follow-up recommendations.
引用
收藏
页码:63 / 72
页数:10
相关论文
共 50 条
  • [41] NATURAL HISTORY OF CONGENITAL ISOLATED MILD AORTIC VALVE AND MILD PULMONARY VALVE STENOSIS: A SINGLE-CENTER FOLLOW-UP STUDY
    Baskan, Serra
    Karaca Ozer, Pelin
    Oztarhan, Kazim
    JOURNAL OF ISTANBUL FACULTY OF MEDICINE-ISTANBUL TIP FAKULTESI DERGISI, 2022, 85 (02): : 242 - 248
  • [42] Similar clinical outcomes with transcatheter aortic valve implantation and surgical aortic valve replacement in octogenarians with aortic stenosis
    Kolar, Tadeja
    Lakic, Nikola
    Kotnik, Alesa
    Stubljar, David
    Fras, Zlatko
    Bunc, Matjaz
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [43] Trauma outcome predictor: An artificial intelligence interactive smartphone tool to predict outcomes in trauma patients
    Maurer, Lydia R.
    Bertsimas, Dimitris
    Bouardi, Hamza Tazi
    El Hechi, Majed
    El Moheb, Mohamad
    Giannoutsou, Katerina
    Zhuo, Daisy
    Dunn, Jack
    Velmahos, George C.
    Kaafarani, Haytham M. A.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2021, 91 (01) : 93 - 99
  • [44] Enhanced detection of severe aortic stenosis via artificial intelligence: a clinical cohort study
    Strange, Geoff
    Stewart, Simon
    Watts, Andrew
    Playford, David
    OPEN HEART, 2023, 10 (02):
  • [45] Outcomes of Transcatheter Aortic Valve Replacement in Asymptomatic or Minimally Symptomatic Aortic Stenosis
    Huded, Chetan P.
    Arnold, Suzanne, V
    Cohen, David J.
    Manandhar, Pratik
    Vemulapalli, Sreekanth
    Saxon, John T.
    Chhatriwalla, Adnan K.
    Kosinski, Andrzej
    Spertus, John A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (21) : 2631 - 2641
  • [46] CARDIOVASCULAR OUTCOMES IN PATIENTS WITH AORTIC STENOSIS AND HYPERTENSION UNDERGOING AORTIC VALVE REPLACEMENT
    Duenas Criado, Karen Alexandra
    Ortiz, Carlos Andres
    Perez, Oscar Mauricio
    Alarcon, Nicolas
    Camacho, Jaime
    Cabrales, Jaime
    Echeverry, Dario
    Pineda, Ivone
    Garcia, Laura
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)
  • [47] Progression of aortic stenosis in patients with bicuspid aortic valve
    Shang, Michael
    Kahler-Quesada, Arianna
    Mori, Makoto
    Yousef, Sameh
    Geirsson, Arnar
    Vallabhajosyula, Prashanth
    JOURNAL OF CARDIAC SURGERY, 2021, 36 (12) : 4665 - 4672
  • [48] Pulmonary hypertension in aortic valve stenosis
    Maeder, Micha T.
    Weber, Lukas
    Rickli, Hans
    TRENDS IN CARDIOVASCULAR MEDICINE, 2022, 32 (02) : 73 - 81
  • [49] Effect of Elevated Body Mass Index on Outcomes of Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis
    Yamashita, Yoshiyuki
    Baudo, Massimo
    Sicouri, Serge
    Zafer, Mujtaba
    Rodriguez, Roberto
    Gnall, Eric M.
    Coady, Paul M.
    Goldman, Scott M.
    Gray, William A.
    Ramlawi, Basel
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2024, 28 (12)
  • [50] Echo Standards: Aortic valve stenosis
    Zechner, P.
    Weihs, W.
    Geiger, H.
    JOURNAL FUR KARDIOLOGIE, 2024, 31 (5-6):