Factors affecting the development of pneumothorax in transthoracic fine-needle aspiration biopsies

被引:0
|
作者
Turkar, Ayla [1 ]
Baysal, Tamer [2 ]
Dumlu, Tunahan Refik [2 ]
Dizman, Ridvan [2 ]
机构
[1] Sureyyapasa Chest Dis & Thorac Surg Training & Re, Radiol Dept, TR-34844 Istanbul, Turkiye
[2] Kartal Dr Lutfi Kirdar Training & Res Hosp, Radiol Dept, Istanbul, Turkiye
关键词
Pneumothorax; needle biopsy; chest tube; computed tomography; PERCUTANEOUS LUNG-BIOPSY; CHEST TUBE PLACEMENT; RISK-FACTORS; COMPLICATIONS; TIME;
D O I
10.1177/02841851251322070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Pneumothorax is the most common complication and reason for hospitalization in needle biopsies of lung. Purpose To investigate the factors that determine the risk and severity of pneumothorax in needle biopsies of lung. Material and Methods Fine-needle aspiration biopsy was performed for diagnostic purposes in 505 patients under the guidance of computed tomography for lung lesions. Findings were analyzed in terms of demographic characteristics of patients' and procedure-related features. Results The mean age of the patients was 65 +/- 9.7 years and mean lesion size was 34.31 +/- 16.99 mm. Pneumothorax developed in 176 patients. The frequency and severity of pneumothorax were higher in male patients (P < 0.001 and P = 0.003). Emphysema was a risk factor for pneumothorax (P = 0.002). The rate of pneumothorax was higher in lower lobe lesions. Pleural length made a significant difference, especially for the severity of pneumothorax. The severity of pneumothorax increased as dwell time increased (P = 0.029). The need for a chest tube was significantly higher in the group with pneumothorax thickness >1 cm (P < 0.001). The requirement for multiple passes increased the risk of developing pneumothorax (P < 0.001). Procedure-related hemorrhage reduced the risk of pneumothorax and prevented the progression of pneumothorax (P < 0.001 for both). The risk of developing pneumothorax was lowest in the supine position (P = 0.001). Conclusion Patient's sex, presence of emphysema, and lesion location are unchangeable patient-dependent factors for the development of pneumothorax. However, the aim should be to plan the process correctly and complete it with a single entry and a short dwell time.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Leiomyosarcoma of the breast: A difficult diagnosis on fine-needle aspiration biopsy
    Wei, XJ
    Hiotis, K
    Garcia, R
    Levine, PH
    DIAGNOSTIC CYTOPATHOLOGY, 2003, 29 (03) : 172 - 178
  • [32] FINE-NEEDLE ASPIRATION CYTOLOGY OF LOCALIZED FIBROUS TUMOR OF PLEURA
    DUSENBERY, D
    GRIMES, MM
    FRABLE, WJ
    DIAGNOSTIC CYTOPATHOLOGY, 1992, 8 (05) : 444 - 450
  • [33] Flow cytometric immunophenotyping in fine-needle aspiration of lymph nodes
    Chung, JG
    Gong, GY
    Huh, JY
    Khang, SK
    Ro, JY
    JOURNAL OF KOREAN MEDICAL SCIENCE, 1999, 14 (04) : 393 - 400
  • [34] Endoscopic Ultrasound and Fine-needle Aspiration for the Diagnosis of Hepatocellular Carcinoma
    Maheshwari, Anurag
    Kantsevoy, Sergey
    Jagannath, Sanjay
    Thuluvath, Paul J.
    CLINICS IN LIVER DISEASE, 2010, 14 (02) : 325 - +
  • [35] The role of fine-needle aspiration biopsy in the diagnosis of malignant tumors
    Rus, Marius
    Popescu, Mircea ioachim
    Ardelean, Ioana adriana
    Andronie-Cioara, Felicia liana
    Bontea, Mihaela gabriela
    Vicas, Razvan M. A. R. I. U. S.
    Bogdan, Iulia denisa
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2024, 65 (01): : 81 - 87
  • [36] Fine-needle aspiration cytology of spindle cell lesions of the breast
    Chhieng, DC
    Cangiarella, JF
    Waisman, J
    Fernandez, G
    Cohen, JM
    CANCER CYTOPATHOLOGY, 1999, 87 (06) : 359 - 371
  • [37] FATAL BLEEDING AFTER FINE-NEEDLE ASPIRATION BIOPSY OF THE LIVER
    MINGOLI, A
    MARZANO, M
    SGARZINI, G
    NARDACCHIONE, F
    CORZANI, F
    MODINI, C
    ITALIAN JOURNAL OF GASTROENTEROLOGY, 1995, 27 (05): : 250 - 251
  • [38] DIAGNOSTIC ACCURACY OF COMPUTED TOMOGRAPHY-GUIDED NONCOAXIAL CUTTING NEEDLE TRANSTHORACIC LUNG BIOPSIES AND THE ASSOCIATED PNEUMOTHORAX
    Ljan, M. Kuku
    Miletic, D.
    Mrsic, E.
    Ostarijas, E.
    Mrsic, A.
    Sosa, I.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (06): : 1829 - 1835
  • [39] Assessment of Factors Affecting the Usefulness and Diagnostic Yield of Core Biopsy Needles with a Side Hole in Endoscopic Ultrasound-Guided Fine-Needle Aspiration
    Inoue, Tadahisa
    Okumura, Fumihiro
    Mizushima, Takashi
    Nishie, Hirotada
    Iwasaki, Hiroyasu
    Anbe, Kaiki
    Ozeki, Takanori
    Kachi, Kenta
    Fukusada, Shigeki
    Suzuki, Yuta
    Sano, Hitoshi
    GUT AND LIVER, 2016, 10 (01) : 51 - 57
  • [40] Delayed pneumothorax after CT-guided percutaneous fine needle aspiration lung biopsy
    Traill, ZC
    Gleeson, FV
    THORAX, 1997, 52 (06) : 581 - 582