Pathology-Independent Expansion of Indications for Rapid-Deployment Aortic Valve Replacement: Midterm Outcomes

被引:0
作者
Bae, Seon Yong [1 ]
Kim, Kyung Hwan [1 ]
Sohn, Suk Ho [1 ]
Kang, Yoonjin [1 ]
Kim, Ji Seong [1 ]
Choi, Jae Woong [1 ]
机构
[1] Seoul Natl Univ Hosp, Seoul Natl Univ Coll, Dept Thorac & Cardiovasc Surg, 101 Daehak Ro, Seoul 03080, South Korea
关键词
aortic valve replacement; rapid-deployment valve; outcomes; hemodynamics; SUTURELESS; TRANSCATHETER; IMPLANTATION; PERFORMANCE; EXPERIENCE; TRIAL;
D O I
10.1055/s-0044-1790240
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background This study evaluated the midterm outcomes of rapid deployment aortic valve replacement (RDAVR) performed regardless of pathology for various aortic valve diseases at a single center. Methods Of the 344 patients who underwent RDAVR using Edwards INTUITY during the study period at our institution, 176 had bicuspid valve diseases (51.2%), 20 had pure aortic regurgitation (5.8%), and 4 had infective endocarditis (1.2%). Median follow-up duration was 28.6 months (maximum: 86.4 months). Midterm clinical outcomes were evaluated, and the changes of valve hemodynamics from early postoperative period to 5 years after surgery were also investigated. Results Mean age was 68.9 +/- 9.8 years, and 46.2% of the patients were female. Isolated RDAVR was performed in 90 patients (26.2%), and concomitant procedures, including aortic surgery (48.8%), mitral valve surgery (20.3%), arrhythmia surgery (9.0%), tricuspid valve surgery (7.0%), and coronary artery bypass grafting (5.5%), were performed in 254 patients (73.8%). Operative mortality occurred in 11 patients (3.2%), and permanent pacemaker implantation was required in 5 patients (1.5%) in early postoperative period. Overall survival rate was 86.9% at 5 years, and cumulative incidence of cardiac death was 6.3% at 5 years. No deterioration of valve hemodynamics was observed at midterm echocardiographic evaluation in either the overall population or for each size of valve. Conclusion Isolated or concomitant aortic valve replacement using rapid-deployment valves was performed for various aortic valve diseases regardless of the underlying pathology at our institution, and the clinical and hemodynamic outcomes were excellent for up to 5 years.
引用
收藏
页数:9
相关论文
共 30 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]   Conventional versus rapid-deployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor [J].
Andreas, Martin ;
Wallner, Stephanie ;
Habertheuer, Andreas ;
Rath, Claus ;
Schauperl, Martin ;
Binder, Thomas ;
Beitzke, Dietrich ;
Rosenhek, Raphael ;
Loewe, Christian ;
Wiedemann, Dominik ;
Kocher, Alfred ;
Laufer, Guenther .
INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) :799-805
[3]   TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve [J].
Barnhart, Glenn R. ;
Accola, Kevin D. ;
Grossi, Eugene A. ;
Woo, Y. Joseph ;
Mumtaz, Mubashir A. ;
Sabik, Joseph F. ;
Slachman, Frank N. ;
Patel, Himanshu J. ;
Borger, Michael A. ;
Garrett, H. Edward, Jr. ;
Rodriguez, Evelio ;
McCarthy, Patrick M. ;
Ryan, William H. ;
Duhay, Francis G. ;
Mack, Michael J. ;
Chitwood, W. Randolph, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (02) :241-+
[4]   Evaluation of a rapid deployment prosthesis strategy for the treatment of aortic valve endocarditis [J].
Belyaev, Sergey ;
Herrmann, Florian Ernst Martin ;
Dashkevich, Alexey ;
Wenke, Klaus ;
Vlachea, Polyxeni ;
von der Linden, Julia ;
Banafsche, Ramin ;
Hagl, Christian ;
Juchem, Gerd .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (05) :1109-1115
[5]   Pledget-Armed Sutures Affect the Haemodynamic Performance of Biologic Aortic Valve Substitutes: A Preliminary Experimental and Computational Study [J].
Capelli, Claudio ;
Corsini, Chiara ;
Biscarini, Dario ;
Ruffini, Francesco ;
Migliavacca, Francesco ;
Kocher, Alfred ;
Laufer, Guenther ;
Taylor, Andrew M. ;
Schievano, Silvia ;
Andreas, Martin ;
Burriesci, Gaetano ;
Rath, Claus .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (01) :17-29
[6]   The Aortic Annulus Stabilization Technique Prevents Paravalvular Leaks after Rapid Deployment Aortic Valve Implantation [J].
Caporali, Elena ;
Lorusso, Roberto ;
Torre, Tiziano ;
Toto, Francesca ;
Pozzoli, Alberto ;
Pedrazzini, Giovanni ;
Demertzis, Stefanos ;
Ferrari, Enrico .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
[7]   Dislocation of a sutureless prosthesis after type I bicuspid aortic valve replacement [J].
Chiariello, Giovanni Alfonso ;
Villa, Emmanuel ;
Messina, Antonio ;
Troise, Giovanni .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 156 (02) :E87-E89
[8]   Rapid-Deployment Aortic Valves for Patients With a Small Aortic Root: A Single-Center Experience [J].
Coti, Iuliana ;
Haberl, Thomas ;
Scherzer, Sabine ;
Shabanian, Shiva ;
Binder, Thomas ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
ANNALS OF THORACIC SURGERY, 2020, 110 (05) :1549-1556
[9]   Outcome of rapid deployment aortic valves: long-term experience after 700 implants [J].
Coti, Iuliana ;
Haberl, Thomas ;
Scherzer, Sabine ;
Werner, Paul ;
Shabanian, Shiva ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
ANNALS OF CARDIOTHORACIC SURGERY, 2020, 9 (04) :314-321
[10]   Conduction disturbances following surgical aortic valve replacement with a rapid-deployment bioprosthesis [J].
Coti, Iuliana ;
Schukro, Christoph ;
Drevinja, Fitim ;
Haberl, Thomas ;
Kaider, Alexandra ;
Kocher, Alfred ;
Laufer, Guenther ;
Andreas, Martin .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2021, 162 (03) :803-811