Combining Contrast-Enhanced Ultrasound with Methylene Blue for Detection of Sentinel Lymph Nodes in Early Breast Cancer

被引:0
|
作者
Zhang, Jie [1 ]
Zhou, Tong-Tong [2 ]
Yang, Meng [1 ]
Zhang, Bo [2 ]
Liu, Jun [1 ]
机构
[1] China Japan Friendship Hosp, Dept Breast & Thyroid Surg, Beijing, Peoples R China
[2] China Japan Friendship Hosp, Dept Ultrasonog, Beijing, Peoples R China
关键词
contrast-enhanced ultrasound; methylene blue; sentinel lymph nodes; breast cancer; DISSECTION; TIME;
D O I
10.12968/hmed.2024.0607
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/Background Sentinel lymph nodes (SLNs) are an important prognostic factor for breast cancer patients, but traditional axillary lymph node dissection methods have many complications, while sentinel lymph node biopsy has been developed as a better method. This study aimed to evaluate the efficiency of combining contrast-enhanced ultrasound (CEUS) with methylene blue for identifying SLNs in early-stage breast cancer patients. Methods This retrospective study included clinical data from 163 female patients with lymph node- negative and T1-2 early breast cancer admitted to China-Japan Friendship Hospital between August 2022 and November 2023. All patients received a periareolar injection of SonoVue followed by ultrasonography to identify SLNs. The methylene blue was used to detect SLNs during the surgery, and the patients underwent sentinel lymph node biopsy. We compared the methylene blue method with combined CEUS and methylene blue to identify the number of SLNs per patient. Furthermore, these two methods were compared to determine the number of SLNs and the number of SLNs positive in 34 SLNs positive patients. Results This study included 163 patients with tumor (T)1-2 node (N)0-3 metastasis (M)0. The identification rate of SLNs was 100% for CEUS. We detected 376 SLNs using a combined CEUS and methylene blue method, with a median of 2 (1, 5). Furthermore, methylene blue identified 627 SLNs, with a median of 3 (1, 12). However, CEUS detected a significantly lower number of SLNs than those identified by methylene blue (p < 0.001). Additionally, metastasis frequency was substantially higher for the combined CEUS and methylene blue method (66.3%, 53/80) compared to methylene blue approach alone (39.5%, 58/147) (p < 0.001). Conclusion Combining CEUS with methylene blue is expected to improve the accuracy of axillary staging in breast cancer patients while reducing surgical trauma and postoperative complications.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Identification of Sentinel Lymph Nodes Using Contrast-Enhanced Ultrasound in Breast Cancer
    Saidha N.K.
    Aggarwal R.
    Sen A.
    Indian Journal of Surgical Oncology, 2018, 9 (3) : 355 - 361
  • [2] Advantages of contrast-enhanced ultrasound in the localization and diagnostics of sentinel lymph nodes in breast cancer
    Yang, Qiuhui
    Fu, Yeqin
    Wang, Jiaxuan
    Yang, Hongjian
    Zhang, Xiping
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2023, 24 (11): : 985 - 997
  • [3] The Value of Contrast-Enhanced Ultrasound in the Detection of Sentinel Lymph Nodes in Malignant Melanoma
    Deng, Xiao-hong
    Du, Zhong-shi
    Wu, Zhou-gui
    Chen, Yu
    Wu, Xian-yi
    Tang, Li-na
    JOURNAL OF ULTRASOUND IN MEDICINE, 2023, 42 (05) : 1015 - 1022
  • [4] The value of contrast-enhanced ultrasound in determining the location of sentinel lymph nodes in breast cancer
    Luo, Jun
    Feng, Liting
    Zhou, Qing
    Chen, Qin
    Liu, Jinping
    Wu, Chihua
    Luo, Jing
    Chen, Jie
    Wu, Hao
    Deng, Wanyue
    CANCER IMAGING, 2021, 21 (01)
  • [5] Variation of sentinel lymphatic channels (SLCs) and sentinel lymph nodes (SLNs) assessed by contrast-enhanced ultrasound (CEUS) in breast cancer patients
    Wang, Ying
    Zhou, Wenbin
    Li, Cuiying
    Gong, Haiyan
    Li, Chunlian
    Yang, Nianzhao
    Zha, Xiaoming
    Chen, Lin
    Xia, Tiansong
    Liu, Xiaoan
    Wang, Minghai
    Ding, Qiang
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2017, 15
  • [6] Contrast enhanced ultrasound of sentinel lymph nodes
    Cui, XinWu
    Ignee, Andre
    Nielsen, Michael Bachmann
    Schreiber-Dietrich, Dagmar
    De Molo, Chiara
    Pirri, Clara
    Jedrzejczyk, Maciej
    Christoph, Dietrich F.
    JOURNAL OF ULTRASONOGRAPHY, 2013, 13 (52) : 73 - 81
  • [7] FEASIBILITY OF CONTRAST-ENHANCED ULTRASOUND-GUIDED BIOPSY OF SENTINEL LYMPH NODES IN DOGS
    Gelb, Hylton R.
    Freeman, Lynetta J.
    Rohleder, Jacob J.
    Snyder, Paul W.
    VETERINARY RADIOLOGY & ULTRASOUND, 2010, 51 (06) : 628 - 633
  • [8] CONTRAST-ENHANCED ULTRASOUND IN LOCATING AXILLARY SENTINEL LYMPH NODES IN PATIENTS WITH BREAST CANCER: A PROSPECTIVE STUDY
    Liu, Yan-Bing
    Xia, Mei
    Li, Yun-Jie
    Li, Sheng
    Li, Hao
    Li, Yun-Ling
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (06) : 1475 - 1483
  • [9] Variation of sentinel lymphatic channels (SLCs) and sentinel lymph nodes (SLNs) assessed by contrast-enhanced ultrasound (CEUS) in breast cancer patients
    Ying Wang
    Wenbin Zhou
    Cuiying Li
    Haiyan Gong
    Chunlian Li
    Nianzhao Yang
    Xiaoming Zha
    Lin Chen
    Tiansong Xia
    Xiaoan Liu
    Minghai Wang
    Qiang Ding
    World Journal of Surgical Oncology, 15
  • [10] Contrast-enhanced ultrasonography and blue dye methods in detection of sentinel lymph nodes following neoadjuvant chemotherapy in initially node positive breast cancer
    Xiufeng Wu
    Lina Tang
    Weiqin Huang
    Shixin Huang
    Wei Peng
    Dan Hu
    Archives of Gynecology and Obstetrics, 2020, 302 : 685 - 692