Evaluation of Functional Outcomes, Survivorship and Complications of Hypoallergenic Fixed-Bearing Medial and Lateral Unicompartmental Knee Arthroplasty: A Minimum 2-Year Follow-Up

被引:0
|
作者
D'Amario, Federico [1 ]
Vitale, Umberto [2 ,3 ]
De Dona, Ferdinando [2 ,3 ]
Ruosi, Luca [2 ,3 ]
Cofone, Alessandro [4 ]
Loppini, Mattia [2 ,3 ]
机构
[1] Humanitas San Pio X, Orthoped Unit, Via Francesco Nava 31, I-20159 Milan, Italy
[2] Humanitas Univ, Dept Biomed Sci, Via Rita Levi Montalcini 4, I-20072 Milan, Italy
[3] IRCCS Humanitas Res Hosp, Via Manzoni 56, I-20089 Milan, Italy
[4] Sapienza Univ Rome, S Andrea Hosp, Dept Orthopaed Surg, Via Grottarossa 1035-1039, I-00189 Rome, Italy
关键词
unicompartmental knee arthroplasty; oxinium; oxidized zirconium; return to sport; patient-reported outcome measures; satisfaction; lateral; survivorship; fixed-bearing; UKA; REPLACEMENT; SURVIVAL;
D O I
10.3390/jcm14051748
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Unicompartmental knee arthroplasty (UKA) is a viable treatment option for patients with isolated knee osteoarthritis. This study evaluated the clinical outcomes of the JII UK (Smith & Nephew, Memphis, TN, USA) hypoallergenic, fixed-bearing UKA implant in a medium cohort of patients undergoing both medial and lateral procedures with a short-term follow-up. Methods: A retrospective review was conducted on 257 consecutive patients who underwent primary UKA using the JII UK implant between December 2020 and December 2022. Clinical outcomes were assessed using the Knee Society Score (KSS), Knee Society Function Score (KSFS), Oxford Knee Score (OKS), UCLA Activity Score, Forgotten Joint Score (FJS-12), and satisfaction. Survivorship analysis was performed, and complications were recorded. Results: At the 2-year follow-up, the implant survival rate was 99.61%. Statistical significant improvements were observed in all clinical scores, with high patient satisfaction. The mean UCLA Activity Score increased from 4.53 preoperatively to 7.3 at 24 months. Conclusions: This study demonstrates promising short-term clinical outcomes for the hypoallergenic fixed-bearing medial and lateral UKA implant, with high patient satisfaction and a low complication rate. Further studies with longer follow-up periods are warranted to confirm these findings.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Survivorship and clinical outcome of the minimally invasive Uniglide medial fixed bearing, all-polyethylene tibia, unicompartmental knee arthroplasty at a mean follow-up of 7.3 years
    Forster-Horvath, C.
    Artz, N.
    Hassaballa, M. A.
    Robinson, J. R.
    Porteous, A. J.
    Murray, J. R.
    Newman, J. H.
    KNEE, 2016, 23 (06) : 981 - 986
  • [22] Outcomes of robotic-arm-assisted medial unicompartmental knee arthroplasty: minimum 3-year follow-up
    Konstantinos Dretakis
    Vasilios G. Igoumenou
    European Journal of Orthopaedic Surgery & Traumatology, 2019, 29 : 1305 - 1311
  • [23] A BMI above 30 results in satisfying outcomes in patients undergoing fixed-bearing lateral unicompartmental knee arthroplasty
    Giordano, Lorenzo
    Maffulli, Nicola
    Morenghi, Emanuela
    Quaglia, Alessandro
    Prospero, Emanuele
    Rosa, Francesco
    Volpi, Piero
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1106 - 1112
  • [24] No difference in long-term outcomes between men and women undergoing medial fixed-bearing cemented unicompartmental knee arthroplasty: A retrospective cohort study with minimum 10-year follow up
    Goh, Graham S.
    Zeng, Gerald Joseph
    Khow, Yong Zhi
    Lo, Ngai-Nung
    Yeo, Seng-Jin
    Liow, Ming Han Lincoln
    KNEE, 2021, 30 : 26 - 34
  • [25] Determination of the Accuracy of Navigated Kinematic Unicompartmental Knee Arthroplasty: A 2-Year Follow-Up
    Grant, Andrea L.
    Doma, Kenji D.
    Hazratwala, Kaushik
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05) : 1443 - 1452
  • [26] Evaluation of Safety and Medium-Term Functional Outcomes of a Medial Fixed-Bearing Unicompartmental Knee Arthroplasty with Ultra-Highly Cross-Linked Polyethylene
    Richards, Megan
    Dobransky, Johanna S.
    Jane, Alanna A.
    Dervin, Geoffrey F.
    JOURNAL OF KNEE SURGERY, 2022, 35 (07) : 804 - 809
  • [27] Comparison of implant position and joint awareness between fixed- and mobile-bearing unicompartmental knee arthroplasty: a minimum of five year follow-up study
    Kim, Man Soo
    Koh, In Jun
    Kim, Chul Kyu
    Choi, Keun Young
    Baek, Jong Won
    In, Yong
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (11) : 2329 - 2336
  • [28] All-Polyethylene Tibial Component Does Not Affect Survivorship of Medial Unicompartmental Knee Arthroplasty at Mid-Term Follow-Up
    Gagliardi, Michele
    Zambianchi, Francesco
    Franz, Alois
    Digennaro, Vitantonio
    Catani, Fabio
    JOURNAL OF KNEE SURGERY, 2021, 34 (13) : 1454 - 1462
  • [29] Relevance of the Tibial Slope on Functional Outcomes in ACL-Deficient and ACL Intact Fixed-Bearing Medial Unicompartmental Knee Arthroplasty
    Plancher, Kevin D.
    Shanmugam, Jaya Prasad
    Brite, Jasmine E.
    Briggs, Karen K.
    Petterson, Stephanie C.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (09) : 3123 - 3130
  • [30] Fixed bearing, all-polyethylene tibia, lateral unicompartmental arthroplasty-A final outcome study with up to 28 year follow-up of a single implant
    Murray, James R. D.
    Smith, James R. A.
    Bray, Rachel
    Robinson, James R.
    White, Paul
    Porteous, Andrew J.
    KNEE, 2021, 29 : 101 - 109