Application value of real-time shear wave elastography in the diagnosis and efficacy evaluation of venous thrombosis

被引:0
作者
Wu, Jing [1 ]
Yang, Xiaoyan [1 ]
Liu, Yun [1 ]
Xi, Fang [1 ]
Lei, Ping [1 ]
机构
[1] First Peoples Hosp Tian Shui, Dept Ultrasound, 105 Jianshe Rd, Tianshui City 741000, Gansu, Peoples R China
关键词
Real-time shear wave elastography; lower-limb deep vein thrombosis; diagnosis; treatment plan;
D O I
10.3233/THC-240386
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
BACKGROUND: Deep vein thrombosis (DVT) of the lower limbs is a venous reflux disorder caused by abnormal coagulation of blood components, primarily characterised by swelling and pain in the lower limbs. Key risk factors include prolonged immobility due to bed rest, pregnancy, postpartum or postoperative states, traumas, malignant tumours and long-term contraceptive use. OBJECTIVE: To investigate the application of real-time shear wave elastography (SWE) in diagnosing lower-limb deep vein thrombosis (DVT). METHODS: A total of 91 patients with DVT were selected and divided into three groups: acute phase (n = 29), subacute phase (n = 30) and chronic phase (n = 32). The Young's modulus of the patients was measured using real-time SWE. The diagnostic efficacy of Young's modulus was evaluated by ROC curves. The hardness differences in Young's modulus across different parts of the same thrombus (head, body and tail) were measured using SWE. RESULTS: Before treatment, significant differences were observed in Young's modulus among patients with DVT (P <0.001). Following anticoagulant therapy, catheter-directed thrombolysis and systemic thrombolysis, significant differences were noted in Young's modulus among patients at the same stage but receiving different treatments (acute phase: P = 0.003; subacute phase: P = 0.014; chronic phase: P = 0.004). Catheter-directed thrombolysis had greater efficacy than anticoagulant therapy. The area under the curve for SWE in staging patients was 0.917, with a sensitivity of 92.36% and specificity of 93.81%. Significant differences in Young's modulus were found between the thrombus head and thrombus body and tail but not between the thrombus body and thrombus tail. CONCLUSION: Measurement of Young's modulus using SWE can serve as an auxiliary means of evaluating staging, predicting pulmonary embolism and selecting treatment in patients with DVT.
引用
收藏
页码:3513 / 3523
页数:11
相关论文
共 50 条
  • [21] Assessment of fibrosis during the development of fatty liver in rabbits using real-time shear-wave elastography
    Lu, Yong-ping
    Wei, Jia
    Xu, Li-rong
    Tang, Yue-yue
    Yuan, Yuan
    Zhang, Yong
    Li, Yun-yan
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2014, 34 (06) : 921 - 928
  • [22] Effect of diet on the measurement of liver elasticity by real-time shear wave elastography in normal subjects
    Ding, Jin
    Li, Li
    Xue, Hong-Yuan
    FOOD SCIENCE AND TECHNOLOGY, 2022, 42
  • [23] INFLUENCE OF MEASUREMENT DEPTH ON THE STIFFNESS ASSESSMENT OF HEALTHY LIVER WITH REAL-TIME SHEAR WAVE ELASTOGRAPHY
    Wang, Cong-Zhi
    Zheng, Jian
    Huang, Ze-Ping
    Xiao, Yang
    Song, Dan
    Zeng, Jie
    Zheng, Hai-Rong
    Zheng, Rong-Qin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (03) : 461 - 469
  • [24] Viscoelasticity in Achilles Tendonopathy: Quantitative Assessment by Using Real-time Shear-Wave Elastography
    Aubry, Sebastien
    Nueffer, Jean-Philippe
    Tanter, Mickael
    Becce, Fabio
    Vidal, Chrystelle
    Michel, Fabrice
    RADIOLOGY, 2015, 274 (03) : 821 - 829
  • [25] Associations of Real-Time Ultrasound and Strain and Shear Wave Elastography with Gastrointestinal Organs: A Systematic Review
    Javed, Nismat
    Ghazanfar, Haider
    Jyala, Abhilasha
    Patel, Harish
    DIAGNOSTICS, 2023, 13 (21)
  • [26] Diagnostic Accuracy of Real-Time Shear Wave Elastography for Staging of Liver Fibrosis: A Meta-Analysis
    Li, Changtian
    Zhang, Changsheng
    Li, Junlai
    Huo, Huiping
    Song, Danfei
    MEDICAL SCIENCE MONITOR, 2016, 22 : 1349 - 1359
  • [27] Real-Time Shear Wave Elastography for Determining the Ideal Site of Liver Biopsy in Diffuse Liver Disease
    Patidar, Yashwant
    Singh, Jitender
    Chatterjee, Navojit
    Mukund, Amar
    Rastogi, Archana
    Kumar, Guresh
    Sharma, Manoj Kumar
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01) : 44 - 53
  • [28] The application of qualitative shear wave elastography in differential diagnosis of thyroid nodules
    Liu, Qian-Qi
    Yang, Zhuo-Wen
    Tian, Jie
    Xing, Ping
    Tang, Hai-Ling
    Qiu, Qian-Yi
    Wu, Chang-Jun
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (04): : 3569 - 3579
  • [29] REAL TIME QUANTITATIVE ELASTOGRAPHY USING SUPERSONIC SHEAR WAVE IMAGING
    Tanter, Mickael
    Pernot, Mathieu
    Montaldo, Gabriel
    Gennisson, Jean-Luc
    Bavu, Eric
    Mace, Emilie
    Nguyen, Thu-Mai
    Couade, Mathieu
    Fink, Mathias
    2010 7TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2010, : 276 - 279
  • [30] Real-Time Elastography in the diagnosis of prostate cancer: a systematic review
    Zhang, Yang
    Meng, Zheying
    Xu, Yanjun
    Lu, Qijie
    Hou, Rui
    Cai, Xiaojun
    Lin, Lizhou
    Luo, You
    Wei, Fengxian
    Zheng, Yuanyi
    Hu, Bing
    MEDICAL ULTRASONOGRAPHY, 2019, 21 (03) : 327 - 335