Artificial Neural Network-based Model for Predicting Cardiologists' Over-apron Dose in CATHLABs

被引:0
作者
Fardid, Reza [1 ,2 ]
Farah, Fatemeh [1 ]
Parsaei, Hossein [3 ]
Rezaei, Hadi [1 ]
Jorat, Mohammad Vahid [4 ]
机构
[1] Shiraz Univ Med Sci, Sch Paramed Sci, Dept Radiol, Shiraz, Iran
[2] Shiraz Univ Med Sci, Sch Paramed Sci, Ionizing & Nonionizing Radiat Protect Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Sch Med, Dept Med Phys & Engn, Shiraz, Iran
[4] Shiraz Univ Med Sci, Cardiovasc Res Ctr, Shiraz, Iran
关键词
Artificial neural network; cardiologists' over apron dose; catheterization laboratory; Monte Carlo simulation; OCCUPATIONAL RADIATION-EXPOSURE; STAFF; DOSIMETRY; INTELLIGENCE; PATIENT; WORKERS;
D O I
10.4103/jmp.jmp_99_24
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: The radiation dose that cardiologists receive in the catheterization laboratory is influenced by various factors. Handling high-stress tasks in interventional cardiology departments may cause physicians to overlook the use of dosimeters. Therefore, it is essential to develop a model for predicting cardiologists' radiation exposure. Materials and Methods: This study developed an artificial neural network (ANN) model to predict the over-apron radiation dose received by cardiologists during catheterization procedures, using dose area product (DAP) values. Leveraging a validated Monte Carlo simulation program, we generated data from simulations with varying spectra (70, 81, and 90 kVp) and tube orientations, resulting in 125 unique scenarios. We then used these data to train a multilayer perceptron neural network with four input features: DAP, energy spectrum, tube angulation, and the resulting cardiologist's dose. Results: The model demonstrated high predictive accuracy with a correlation coefficient (R-value) of 0.95 and a root mean square error (RMSE) of 3.68 mu Sv, outperforming a traditional linear regression model, which had an R-value of 0.48 and an RMSE of 18.15 mu Sv. This significant improvement highlights the effectiveness of advanced techniques such as ANNs in accurately predicting occupational radiation doses. Conclusion: This study underscores the potential of ANN models for accurate radiation dose prediction, enhancing safety protocols, and providing a reliable tool for real-time exposure assessment in clinical settings. Future research should focus on broader validation and integration into real-time monitoring systems.
引用
收藏
页码:623 / 630
页数:8
相关论文
共 48 条
[1]  
Abaza AM, 2018, Am. J. Mod. Phys., V7, P21, DOI DOI 10.11648/J.AJMP.20180701.13
[2]  
Abdelrahman ME, 2019, 2 INT C MONT CARL TE
[3]   A knowledge-based system for brain tumor segmentation using only 3D FLAIR images [J].
Amirmoezzi, Yalda ;
Salehi, Sina ;
Parsaei, Hossein ;
Kazemi, Kamran ;
Jahromi, Amin Torabi .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (02) :529-540
[4]   IMPROVEMENT OF DOSE ESTIMATION PROCESS USING ARTIFICIAL NEURAL NETWORKS [J].
Amit, Gal ;
Datz, Hanan .
RADIATION PROTECTION DOSIMETRY, 2019, 184 (01) :36-43
[5]  
Association IRP, 2017, IRPA guidance on implementation of eye dose monitoring and eye protection of workers
[6]   Radiation exposure to staff during fluoroscopic endoscopic procedures [J].
Badawy, Mohamed Khaldoun ;
Henely-Smith, Ellen ;
Hasmat, Solaiman .
DEN OPEN, 2023, 3 (01)
[7]   Use of Artificial Intelligence to Reduce Radiation Exposure at Fluoroscopy-Guided Endoscopic Procedures [J].
Bang, Ji Young ;
Hough, Matthew ;
Hawes, Robert H. ;
Varadarajulu, Shyam .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2020, 115 (04) :555-561
[8]   Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo method [J].
Bozkurt, A. ;
Bor, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :317-330
[9]   Artificial intelligence in medicine: current trends and future possibilities [J].
Buch, Varun H. ;
Ahmed, Irfan ;
Maruthappu, Mahiben .
BRITISH JOURNAL OF GENERAL PRACTICE, 2018, 68 (668) :143-144
[10]   Analysis of radiation workers' dose records in the Korean National Dose Registry [J].
Choi, SY ;
Kim, TH ;
Chung, CK ;
Cho, CK ;
Paik, NS .
RADIATION PROTECTION DOSIMETRY, 2001, 95 (02) :143-148