The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods

被引:0
|
作者
Siotou, Kalliopi [1 ]
Chountalas, Theofanis [2 ]
Katsavrias, Athanasios [3 ]
Siotos, Charalampos [4 ]
Mpalias, Konstantinos [3 ]
Semitekolos, Dionysios [3 ]
Charitidis, Constantinos [3 ]
Tsolakis, Apostolos I. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Dept Orthodont, Athens, Greece
[2] Natl Tech Univ Athens, Mech Engn Sch, Dept Lab Heterogeneous Mixtures & Combust Syst, Athens, Greece
[3] Natl Tech Univ Athens, Chem Engn Sch, Res Lab Adv Composite Nano Mat & Nanotechnol, Zografos, Greece
[4] Rush Univ, Med Ctr, Div Plast & Reconstruct Surg, Chicago, IL USA
关键词
ageing; clear aligner; intraoral; mechanical properties; orthodontic aligners; FORCE DELIVERY PROPERTIES; BITE FORCE; EFFICIENCY;
D O I
10.1111/ocr.12867
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveAlthough the technique of orthodontic aligners has risen in popularity, their mechanical properties have not been thoroughly investigated. The aim of this study was to evaluate the mechanical properties of the orthodontic aligners Clear Aligner after intraoral use for 7, 10 and 14 days, and to compare them with as-received aligners (0 days). It was also sought to examine the properties of the unprocessed raw material (polyethylene glycol terephthalate) used to manufacture these aligners.Materials/MethodsThirty-two aligners by four patients were evaluated and studied at 0, 7, 10, 14 days of use. Each aligner was divided into three segments (two posterior and one anterior), which resulted in 96 samples. Also, 16 samples of unprocessed material were studied. For all samples, elastic modulus, ultimate tensile stress (UTS) and yield stress were calculated by conducting tensile testing. Additionally, material hardness was tested. The two-tailed Mann-Whitney test was performed, having set the level of significance at p = 0.05.ResultsAnalysis of the measurements indicated a statistically significant decrease in elastic modulus between days 0 and 14 of use, of UTS between days 0 and 7, 7 and 10, and of yield stress between days 0 and 7. For hardness, in every period, posterior segments demonstrated significantly higher values than anterior segments. All properties of the unprocessed material were statistically significantly higher than the processed samples.ConclusionsThe unprocessed material presented significant differences in every property tested in comparison to the processed aligners. The processed material showed further deterioration over time during use. The present study provides evidence that thermoforming and ageing affect the mechanical properties of the aligners.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [21] Assessment of the Effect of Thermoforming Process and Simulated Aging on the Mechanical Properties of Clear Aligner Material
    Bhate, Manjiri
    Nagesh, Shweta
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [22] Mechanical Properties of 3D Printed Orthodontic Aligners Produced by Different Commercially Available Printers - An In-Vitro Study
    Bhardwaj, Amit
    Mishra, Kratika
    Pandey, Ankita
    Kirtiwar, Deepali
    Kharche, Asmita
    Agaldiviti, Prashanth
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : 1431 - 1432
  • [23] Optical properties of orthodontic aligners—spectrophotometry analysis of three types before and after aging
    Luca Lombardo
    Angela Arreghini
    Roberta Maccarrone
    Anna Bianchi
    Santo Scalia
    Giuseppe Siciliani
    Progress in Orthodontics, 16
  • [24] Effects of different tooth movement patterns and aligner thicknesses on maxillary arch expansion with clear aligners: a three-dimensional finite element study
    Li, Na
    Wang, ChunJuan
    Yang, Min
    Chen, DingGen
    Tang, MingYuan
    Li, DaoKun
    Qiu, ShengLei
    Chen, Qi
    Feng, Yi
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [25] External apical root resorption in non-extraction cases after clear aligner therapy or fixed orthodontic treatment
    Yi, Jianru
    Xiao, Jiani
    Li, Yu
    Li, Xiaobing
    Zhao, Zhihe
    JOURNAL OF DENTAL SCIENCES, 2018, 13 (01) : 48 - 53
  • [26] Evaluation of Mechanical Properties of Different Thermoplastic Orthodontic Retainer Materials after Thermoforming and Thermocycling
    Albilali, Alaa T.
    Baras, Bashayer H.
    Aldosari, Mohammad A.
    POLYMERS, 2023, 15 (07)
  • [27] An Assessment of the Mechanical Deformation Behavior of Three Different Clear Aligner Materials: A Digital Image Correlation Analysis
    Olteanu, Nicolae Daniel
    Szuhanek, Camelia
    Rosu, Sorana Nicoleta
    Chitariu, Dragos Florin
    Seghedin, Nicolae
    Panaite, Tinela
    Casalean, Amalia
    Zetu, Irina Nicoleta
    APPLIED SCIENCES-BASEL, 2024, 14 (17):
  • [28] Optical properties of orthodontic aligners-spectrophotometry analysis of three types before and after aging
    Lombardo, Luca
    Arreghini, Angela
    Maccarrone, Roberta
    Bianchi, Anna
    Scalia, Santo
    Siciliani, Giuseppe
    PROGRESS IN ORTHODONTICS, 2015, 16
  • [29] Chemical analysis and performance evaluation of ClearCorrect® aligners as received and after intraoral use: Implications for durability, aesthetics, and patient safety
    Bouchema, TSE.
    Saunier, J.
    Mauriello, J.
    Tfayli, A.
    Savard, B.
    Yagoubi, N.
    DENTAL MATERIALS, 2024, 40 (12) : 2135 - 2147
  • [30] Thermo-mechanical properties of 3D printed photocurable shape memory resin for clear aligners
    Lee, Se Yeon
    Kim, Hoon
    Kim, Hyun-Joong
    Chung, Chooryung J.
    Choi, Yoon Jeong
    Kim, Su-Jung
    Cha, Jung-Yul
    SCIENTIFIC REPORTS, 2022, 12 (01)