The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods

被引:0
|
作者
Siotou, Kalliopi [1 ]
Chountalas, Theofanis [2 ]
Katsavrias, Athanasios [3 ]
Siotos, Charalampos [4 ]
Mpalias, Konstantinos [3 ]
Semitekolos, Dionysios [3 ]
Charitidis, Constantinos [3 ]
Tsolakis, Apostolos I. [1 ]
机构
[1] Natl & Kapodistrian Univ Athens, Dept Orthodont, Athens, Greece
[2] Natl Tech Univ Athens, Mech Engn Sch, Dept Lab Heterogeneous Mixtures & Combust Syst, Athens, Greece
[3] Natl Tech Univ Athens, Chem Engn Sch, Res Lab Adv Composite Nano Mat & Nanotechnol, Zografos, Greece
[4] Rush Univ, Med Ctr, Div Plast & Reconstruct Surg, Chicago, IL USA
关键词
ageing; clear aligner; intraoral; mechanical properties; orthodontic aligners; FORCE DELIVERY PROPERTIES; BITE FORCE; EFFICIENCY;
D O I
10.1111/ocr.12867
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveAlthough the technique of orthodontic aligners has risen in popularity, their mechanical properties have not been thoroughly investigated. The aim of this study was to evaluate the mechanical properties of the orthodontic aligners Clear Aligner after intraoral use for 7, 10 and 14 days, and to compare them with as-received aligners (0 days). It was also sought to examine the properties of the unprocessed raw material (polyethylene glycol terephthalate) used to manufacture these aligners.Materials/MethodsThirty-two aligners by four patients were evaluated and studied at 0, 7, 10, 14 days of use. Each aligner was divided into three segments (two posterior and one anterior), which resulted in 96 samples. Also, 16 samples of unprocessed material were studied. For all samples, elastic modulus, ultimate tensile stress (UTS) and yield stress were calculated by conducting tensile testing. Additionally, material hardness was tested. The two-tailed Mann-Whitney test was performed, having set the level of significance at p = 0.05.ResultsAnalysis of the measurements indicated a statistically significant decrease in elastic modulus between days 0 and 14 of use, of UTS between days 0 and 7, 7 and 10, and of yield stress between days 0 and 7. For hardness, in every period, posterior segments demonstrated significantly higher values than anterior segments. All properties of the unprocessed material were statistically significantly higher than the processed samples.ConclusionsThe unprocessed material presented significant differences in every property tested in comparison to the processed aligners. The processed material showed further deterioration over time during use. The present study provides evidence that thermoforming and ageing affect the mechanical properties of the aligners.
引用
收藏
页码:253 / 260
页数:8
相关论文
共 50 条
  • [1] The effectiveness of orthodontic treatment with clear aligners in different thicknesses
    Cengiz, Saniye Merve
    Goymen, Merve
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [2] Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages
    Olteanu, Nicolae Daniel
    Taraboanta, Ionut
    Panaite, Tinela
    Balcos, Carina
    Rosu, Sorana Nicoleta
    Vieriu, Raluca Maria
    Dinu, Stefania
    Zetu, Irina Nicoleta
    MATERIALS, 2024, 17 (16)
  • [3] Physical and chemical changes of clear aligners after thermoforming and intraoral exposure
    Dalaie, Kazem
    Rafsanjan, Katayoun Talebi
    Nojehdehian, Hanieh
    Namazi, Zahra
    APOS TRENDS IN ORTHODONTICS, 2024, 14 (04) : 235 - 247
  • [4] Accuracy of clear aligners in the orthodontic rotational movement using different attachment configurations
    Fiorillo, Gianluigi
    Campobasso, Alessandra
    Croce, Silvia
    Hussain, Umar
    Battista, Giovanni
    Lo Muzio, Eleonora
    Mandelli, Gualtiero
    Ambrosi, Alessandro
    Gastaldi, Giorgio
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2024, 27 (06) : 996 - 1003
  • [5] Εffect of cleansers on the composition and mechanical properties of orthodontic aligners in vitro
    Anna Iliadi
    Vera Enzler
    Georgios Polychronis
    Timo Peltomaki
    Spiros Zinelis
    Theodore Eliades
    Progress in Orthodontics, 23
  • [6] Εffect of cleansers on the composition and mechanical properties of orthodontic aligners in vitro
    Iliadi, Anna
    Enzler, Vera
    Polychronis, Georgios
    Peltomaki, Timo
    Zinelis, Spiros
    Eliades, Theodore
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [7] Changes in surface morphology, chemical and mechanical properties of clear aligners during intraoral usage: A systematic review and meta-analysis
    Bakdach, Wesam Mhd Mounir
    Haiba, Majed
    Hadad, Rania
    INTERNATIONAL ORTHODONTICS, 2022, 20 (01)
  • [8] The effect of time on mechanical properties of biocompatible photopolymer resins used for fabrication of clear dental aligners
    Milovanovic, Aleksa
    Sedmak, Aleksandar
    Golubovic, Zorana
    Mihajlovic, Ksenija Zelic
    Zurkic, Aleksandar
    Trajkovic, Isaak
    Milosevic, Milos
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 119
  • [9] Comparative analysis of mechanical properties of orthodontic aligners produced by different contemporary 3D printers
    Zinelis, Spiros
    Panayi, Nearchos
    Polychronis, Georgios
    Papageorgiou, Spyridon N.
    Eliades, Theodore
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2022, 25 (03) : 336 - 341
  • [10] Effects of different designs of orthodontic clear aligners on the maxillary central incisors in the tooth extraction cases: a biomechanical study
    Meng, Xuehuan
    Wang, Chunjuan
    Xu, Wenjie
    Wang, Rui
    Zheng, Leilei
    Wang, Chao
    Aversa, Raffaella
    Fan, Yubo
    BMC ORAL HEALTH, 2023, 23 (01)